Impact of a New Motion-Correction Algorithm on Image Quality of Low-Dose Coronary CT Angiography in Patients with Insufficient Heart Rate Control

被引:41
作者
Fuchs, Tobias A. [1 ]
Stehli, Julia [1 ]
Dougoud, Svetlana [1 ]
Fiechter, Michael [1 ]
Sah, Bert-Ram [1 ]
Buechel, Ronny R. [1 ]
Bull, Sacha [1 ]
Gaemperli, Oliver [1 ]
Kaufmann, Philipp A. [1 ]
机构
[1] Univ Zurich Hosp, Dept Nucl Med & Cardiac Imaging, CH-8091 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Coronary CT angiography (CCTA); insufficient heart rate control; motion correction; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; RATE-VARIABILITY; ARTERY MOTION; RECONSTRUCTION; FEASIBILITY; ACQUISITION; EXPERIENCE;
D O I
10.1016/j.acra.2013.10.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Prospective electrocardiogram (ECG) triggering allows coronary computed tomography angiography (CCTA) Scanning with low radiation dose but requires heart rates below 63 beats/min. We assessed the impact of a novel vendor-specific motion-correction algorithm on image quality and interpretability of low-dose CCTA acquired despite insufficient heart rate control. Materials and Methods: In 40 patients undergoing CCTA for the assessment of known or suspected coronary artery disease who did not reach the target heart rate below 63 beats/min despite beta-blockade before prospective low-dose scanning, the temporal acquisition window was increased (80 ms additional padding). The new algorithm detects and integrates vessel path and velocity from adjacent cardiac phases for motion correction. Two blinded observers assessed image quality on a 4-point Likert scale (1, nonevaluative; 2, reduced but evaluative; 3, good;,and 4, excellent) and the fraction of interpretable segments (score 2 or more) using motion correction versus standard reconstruction. Results: Image reconstruction with motion correction resulted in an increased median coronary artery image quality score (excellent inter-observer agreement, kappa=0.85) compared to standard reconstruction (3.4 vs. 3.0, P < .001). Consequently, motion-corrected-reconstruction significantly improved the overall interpretability of coronary arteries (from 78% to 88%, P < .001). Estimated mean effective radiation dose was 2.3 +/- 0.8 mSv. Conclusions: A novel, vendor-specific, motion-corrected, reconstruction algorithm improves image quality and interpretability of prospectively ECG-triggered low-dose CCTA despite insufficient heart rate control.
引用
收藏
页码:312 / 317
页数:6
相关论文
共 30 条
[1]  
Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
[2]   Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition [J].
Achenbach, Stephan ;
Marwan, Mohamed ;
Ropers, Dieter ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Kuettner, Axel ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :340-346
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Nonrigid registration-based coronary artery motion correction for cardiac computed tomography [J].
Bhagalia, Roshni ;
Pack, Jed D. ;
Miller, James V. ;
Iatrou, Maria .
MEDICAL PHYSICS, 2012, 39 (07) :4245-4254
[5]   Low-Dose Computed Tomography Coronary Angiography With Prospective Electrocardiogram Triggering Feasibility in a Large Population [J].
Buechel, Ronny R. ;
Husmann, Lars ;
Herzog, Bernhard A. ;
Pazhenkottil, Aju P. ;
Nkoulou, Rene ;
Ghadri, Jelena R. ;
Treyer, Valerie ;
von Schulthess, Patrick ;
Kaufmann, Philipp A. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (03) :332-336
[6]   Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation [J].
Dewey, Marc ;
Zimmermann, Elke ;
Deissenrieder, Florian ;
Laule, Michael ;
Duebel, Hans-Peter ;
Schlattmann, Peter ;
Knebel, Fabian ;
Rutsch, Wolfgang ;
Hamm, Bernd .
CIRCULATION, 2009, 120 (10) :867-875
[7]  
Eltinge JL, 1997, STATA TECH B, V6
[8]   CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis [J].
Fuchs, Tobias A. ;
Fiechter, Michael ;
Gebhard, Catherine ;
Stehli, Julia ;
Ghadri, Jelena R. ;
Kazakauskaite, Egle ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Gaemperli, Oliver ;
Kaufmann, Philipp A. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (03) :719-724
[9]  
Gebhard C, 2012, INT J CARDIOL
[10]   Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition [J].
Ghadri, Jelena R. ;
Kueest, Silke M. ;
Goetti, Robert ;
Fiechter, Michael ;
Pazhenkottil, Aju P. ;
Nkoulou, Rene N. ;
Kuhn, Felix P. ;
Pietsch, Carsten ;
von Schulthess, Patrick ;
Gaemperli, Oliver ;
Templin, Christian ;
Kaufmann, Philipp A. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05) :1217-1225