A ratiometric fluorescent probe for iron(III) and its application for detection of iron(III) in human blood serum

被引:95
作者
Long, Lingliang [1 ,2 ]
Zhou, Liping [1 ,2 ]
Wang, Lin [1 ,2 ]
Meng, Suci [1 ,2 ]
Gong, Aihua [3 ]
Zhang, Chi [1 ,2 ]
机构
[1] Jiangsu Univ, Sci Res Acad, Funct Mol Mat Res Ctr, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Jiangsu Univ, Sch Chem & Chem Engn, Zhenjiang 212013, Jiangsu, Peoples R China
[3] Jiangsu Univ, Sch Med Sci & Lab Med, Zhenjiang 212013, Jiangsu, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Fluorescent probes; Fluorescence; Dyes/pigments; Ratiometric; Iron; III-AMPLIFIED FLUORESCENCE; IRON-DEFICIENCY ANEMIA; TRANSFERRIN-BOUND IRON; LIVING CELLS; HEPATOCELLULAR-CARCINOMA; CELLULAR UPTAKE; FE3+; SENSOR; ACETALS; DEPROTECTION;
D O I
10.1016/j.aca.2013.12.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and versatile ratiometric fluorescent Fe3+ detecting system, probe 1, was rationally developed based on the Fe3+-mediated deprotection of acetal reaction. Notably, this reaction was firstly employed to design fluorescent Fe3+ probe. Upon treatment with Fe3+, probe 1 showed ratiometric response, with the fluorescence spectra displaying significant red shift (up to 132 nm) and the emission ratio value (I522/I390) exhibiting approximately 2362-fold enhancement. In addition, the probe is highly sensitive (with the detection limit of 0.12 mu M) and highly selective to Fe3+ over other biologically relevant metal ions. The sensing reaction product of the probe with Fe3+ was confirmed by NMR spectra and mass spectrometry. TD-DFT calculation has demonstrated that the ratiometric response of probe 1 to Fe3+ is due to the regulation of intramolecular charge transfer (ICT) efficiency. Moreover, the practical utility in fluorescence detection of Fe3+ in human blood serum was also conducted, and probe 1 represents the first ratiometric fluorescent probe that can be used to monitor Fe3+ level in human blood serum. Finally, probe 1 was further employed in living cell imaging with pancreatic cancer cells, in which it displayed low cytotoxicity, satisfactory cell permeability, and selective ratiometric response to Fe3+. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 61 条
[1]   Calcein as a fluorescent iron chemosensor for the determination of low molecular weight iron in biological fluids [J].
Ali, A ;
Zhang, Q ;
Dai, JS ;
Huang, X .
BIOMETALS, 2003, 16 (02) :285-293
[2]   Common variants in TMPRSS6 are associated with iron status and erythrocyte volume [J].
Benyamin, Beben ;
Ferreira, Manuel A. R. ;
Willemsen, Gonneke ;
Gordon, Scott ;
Middelberg, Rita P. S. ;
McEvoy, Brian P. ;
Hottenga, Jouke-Jan ;
Henders, Anjali K. ;
Campbell, Megan J. ;
Wallace, Leanne ;
Frazer, Ian H. ;
Heath, Andrew C. ;
de Geus, Eco J. C. ;
Nyholt, Dale R. ;
Visscher, Peter M. ;
Penninx, Brenda W. ;
Boomsma, Dorret I. ;
Martin, Nicholas G. ;
Montgomery, Grant W. ;
Whitfield, John B. .
NATURE GENETICS, 2009, 41 (11) :1173-1175
[3]   Desferrioxamine-chelatable iron, a component of serum non-transferrin-bound iron, used for assessing chelation therapy [J].
Breuer, W ;
Ermers, MJJ ;
Pootrakul, P ;
Abramov, A ;
Hershko, C ;
Cabantchik, ZI .
BLOOD, 2001, 97 (03) :792-798
[4]   On the development of sensor molecules that display FeIII-amplified fluorescence [J].
Bricks, JL ;
Kovalchuk, A ;
Trieflinger, C ;
Nofz, M ;
Büschel, M ;
Tolmachev, AI ;
Daub, J ;
Rurack, K .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (39) :13522-13529
[5]   Stable isotope labelling and FPLC-ICP-SFMS for the accurate determination of clinical iron status parameters in human serum [J].
Busto, M. Estela del Castillo ;
Montes-Bayon, Maria ;
Bettmer, Joerg ;
Sanz-Medel, Alfredo .
ANALYST, 2008, 133 (03) :379-384
[6]   A Turn-on Fluorescent Iron Complex and Its Cellular Uptake [J].
Chartres, Jy D. ;
Busby, Michael ;
Riley, Mark J. ;
Davis, Jason J. ;
Bernhardt, Paul V. .
INORGANIC CHEMISTRY, 2011, 50 (18) :9178-9183
[7]   FRET-based ratiometric fluorescent probes for selective Fe3+ sensing and their applications in mitochondria [J].
Chen, Wen-dan ;
Gong, Wei-tao ;
Ye, Zhi-qiang ;
Lin, Yuan ;
Ning, Gui-ling .
DALTON TRANSACTIONS, 2013, 42 (28) :10093-10096
[8]   Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives [J].
Chen, Xiaoqiang ;
Pradhan, Tuhin ;
Wang, Fang ;
Kim, Jong Seung ;
Yoon, Juyoung .
CHEMICAL REVIEWS, 2012, 112 (03) :1910-1956
[9]   Parasite maturation and host serum iron influence the labile iron pool of erythrocyte stage Plasmodium falciparum [J].
Clark, Martha ;
Fisher, Nancy C. ;
Kasthuri, Raj ;
Hand, Carla Cerami .
BRITISH JOURNAL OF HAEMATOLOGY, 2013, 161 (02) :262-269
[10]  
Crichton R., 2001, INORGANIC BIOCHEMIST