Photoelectrochemical and Non-Enzymatic Glucose Sensor Based on Modified Fehling's Test by Using Ti/TiO2 NTs-rGO-Cu2O Electrode

被引:17
作者
Cakiroglu, Bekir [1 ]
Ozacar, Mahmut [1 ,2 ]
机构
[1] Sakarya Univ, Biomed Magnet & Semicond Mat Res Ctr BIMAS RC, TR-54187 Sakarya, Turkey
[2] Sakarya Univ, Sci & Arts Fac, Dept Chem, TR-54187 Sakarya, Turkey
关键词
BIOSENSOR; OXIDE; HETEROSTRUCTURE; CU2O; NANOCOMPOSITE; REDUCTION; NANOTUBES; COMPOSITE; OXIDATION; SURFACE;
D O I
10.1149/2.1201908jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Herein, semiconductor Cu2O/reduced graphene oxide (rGO) coated TiO2 nanotubes (NTs) arrayed titanium foil was used as a photoelectrochemical (PEC) glucose sensor. The concentration of Cu2O nanoparticles (NPs) obtained by Fehling's solution is directly proportional to glucose amount, and the sensor combined the sensitive feature of PEC analysis and low-cost production of enzymeless sensors with the modified Fehling's test for the first time. The greatly enhanced photocurrent can be attributed to the p-n heterojunction formation between Cu2O NPs and TiO2 NTs, combined with the excellent conductive rGO, which can simultaneously enhance the charge separation efficiency and facilitate electron transfer. Also, rGO caused Cu2O NPs to cohere with each other on the electrode surface. The wide linear measurement range was found to be 0.0007-20 mM, with a sensitivity of 0.87 mu AmM-1 at 0 V vs Ag/AgCl. The proposed nanocomposite can be used for the glucose measurements in beverages. (C) 2019 The Electrochemical Society.
引用
收藏
页码:B728 / B734
页数:7
相关论文
共 50 条
[31]   Cu2O hollow microspheres as electrode materials for non-enzymatic electrochemical detection of glucose [J].
Zhang, Fan ;
Wang, Yihui ;
Wu, Xiujuan ;
Zhang, Hao ;
Huang, Shan ;
Yang, Ying ;
Xie, Adi ;
Wang, Mingyan .
MICRO & NANO LETTERS, 2020, 15 (15) :1071-1074
[32]   Enhancing glucose detection: Vanadium-doped TiO2 (V0.07Ti0.93O2) as non-enzymatic biosensor [J].
Rao, Lavanya ;
Bhat, Badekai Ramachandra .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2024, 35 (16)
[33]   Synthesis of Ag-Au/Reduced Graphene Oxide/TiO2 Nanocomposites: Application as a Non-enzymatic Amperometric H2O2 Sensor [J].
Han, Long ;
Cui, Shoufang ;
Deng, Dongmei ;
Li, Yuanyuan ;
Yan, Xiaoxia ;
He, Haibo ;
Luo, Liqiang .
CURRENT ANALYTICAL CHEMISTRY, 2020, 16 (04) :485-492
[34]   Nanostructured Cu2O deposited on TiO2 nanotube arrays for ultra-sensitive non-enzymatic glucose electrochemical biosensor [J].
Bittu Kumar ;
Sudip Kumar Sinha .
Ionics, 2023, 29 :793-805
[35]   Facile synthesis of uniform CuO/Cu2O composite hollow microspheres for a non-enzymatic glucose sensor [J].
Zhang, Fan ;
Xiao, Xin ;
Wang, Jie ;
Huang, Shan ;
Zhang, Hao ;
Zhang, Weidong ;
Guo, Xi ;
Zhang, Dongen ;
Wang, Mingyan .
MATERIALS RESEARCH EXPRESS, 2019, 6 (11)
[36]   Non-enzymatic electrochemical sensor based on Cu2O/AuCu/Cu composite for hydrogen peroxide detection [J].
Liang, Xiaoyu ;
Li, Weixiang ;
Han, Hongliang ;
Ma, Zhanfang .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 834 :43-48
[37]   A novel non-enzymatic glucose sensor modified with Fe2O3 nanowire arrays [J].
Cao, Xia ;
Wang, Ning .
ANALYST, 2011, 136 (20) :4241-4246
[38]   Reticular-vein-like Cu@Cu2O/reduced graphene oxide nanocomposites for a non-enzymatic glucose sensor [J].
Huo, Huanhuan ;
Guo, Chunyan ;
Li, Guilin ;
Han, Xu ;
Xu, Cailing .
RSC ADVANCES, 2014, 4 (39) :20459-20465
[39]   Non-enzymatic hydrogen peroxide sensor based on MnO2-ordered mesoporous carbon composite modified electrode [J].
Luo, Liqiang ;
Li, Fang ;
Zhu, Limei ;
Zhang, Zhao ;
Ding, Yaping ;
Deng, Dongmei .
ELECTROCHIMICA ACTA, 2012, 77 :179-183
[40]   Highly sensitive non-enzymatic glucose sensor based on over-oxidized polypyrrole nanowires modified with Ni(OH)2 nanoflakes [J].
Yang, Jiao ;
Cho, Misuk ;
Pang, Changhyun ;
Lee, Youngkwan .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 :93-101