Removal of Pb and Cd from aqueous media and fish liver using novel polyurethane foam functionalized with pyrazolone as a new metal ion collector

被引:16
作者
Burham, N. [1 ]
Abdel-Azeem, S. M. [1 ]
El-Shahat, M. F. [2 ]
机构
[1] Fayoum Univ, Fac Sci, Dept Chem, Fayoum City, Egypt
[2] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2009年 / 7卷 / 03期
关键词
Functionalized polyurethane foam; Pyrazolone; Heavy metals; Fish liver; Tap water; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; AMBERLITE XAD-2; ONLINE PRECONCENTRATION; LINE PRECONCENTRATION; CONTINUOUS-FLOW; TRACE-ELEMENTS; WATER SAMPLES; RESIN; LEAD;
D O I
10.2478/s11532-009-0051-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present paper, an off-line preconcentration procedure for the determination of cadmium and lead by flame atomic absorption spectrometry (FAAS) is proposed. Polyurethane foam (PUF) functionalized with o-aminophenol (o-AP) followed by Pyrazolone (Pyr) packed in a minicolumn was used as a sorbent material. The metals were retained on the modified PUF, from which it could be eluted and effectively preconcentrated. The detection limits were 0.072 and 0.016 mu g L-1 for Pb and Cd respectively. Enrichment factors were 250 and 319 for lead and cadmium respectively. The procedure has been applied successfully to metal determination in water samples, fish liver and reference material.
引用
收藏
页码:576 / 585
页数:10
相关论文
共 32 条
[11]   An on-line solid phase extraction system using polyurethane foam for the spectrophotometric determination of nickel in silicates and alloys [J].
Ferreira, SLC ;
de Jesus, DS ;
Cassella, RJ ;
Costa, ACS ;
de Carvalho, MS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :287-292
[12]   Uptake of heavy metals from synthetic aqueous solutions using modified PEI - silica gels [J].
Ghoul, M ;
Bacquet, M ;
Morcellet, M .
WATER RESEARCH, 2003, 37 (04) :729-734
[13]   8-Hydroxyquinoline anchored to silica gel via new moderate size linker: synthesis and applications as a metal ion collector for their flame atomic absorption spectrometric determination [J].
Goswami, A ;
Singh, AK ;
Venkataramani, B .
TALANTA, 2003, 60 (06) :1141-1154
[14]   Preconcentration and determination of trace elements with 2-aminoacetylthiophenol functionalized Amberlite XAD-2 by inductively coupled plasma-atomic emission spectrometry [J].
Guo, Y ;
Din, BJ ;
Liu, YG ;
Chang, XJ ;
Meng, SM ;
Liu, JH .
TALANTA, 2004, 62 (01) :209-215
[15]   Amberlite XAD-2 functionalized with o-aminophenol:: synthesis and applications as extractant for copper(II), cobalt(II), cadmium(II), nickel(lI), zinc(II) and lead(II) [J].
Kumar, M ;
Rathore, DPS ;
Singh, AK .
TALANTA, 2000, 51 (06) :1187-1196
[16]   Amberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copper [J].
Lemos, VA ;
Baliza, PX .
TALANTA, 2005, 67 (03) :564-570
[17]   On-line preconcentration system for lead determination in seafood samples by flame atomic absorption spectrometry using polyurethane foam loaded with 2-(2-benzothiazolylazo)-2-p-cresol [J].
Lemos, VA ;
Ferreira, SLC .
ANALYTICA CHIMICA ACTA, 2001, 441 (02) :281-289
[18]   On-line preconcentration using a resin functionalized with 3,4-dihydroxybenzoic acid for the determination of trace elements in biological samples by thermospray flame furnace atomic absorption spectrometry [J].
Lemos, Valfredo A. ;
Bezerra, Marcos A. ;
Amorim, Fabio A. C. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 157 (2-3) :613-619
[19]   Determination of trace lead in water samples by graphite furnace atomic absorption spectrometry after preconcentration with nanometer titanium dioxide immobilized on silica gel [J].
Liu, Rui ;
Liang, Pei .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (01) :166-171
[20]   Biosorption and preconcentration of lead and cadmium on waste Chinese herb Pang, Da Hai [J].
Liu, Yongwen ;
Chang, Xijun ;
Guo, Yong ;
Meng, Shuangming .
JOURNAL OF HAZARDOUS MATERIALS, 2006, 135 (1-3) :389-394