Voltammetric Determination of 4-Nitrobiphenyl at a Mercury Meniscus Modified Silver Solid Amalgam Electrode

被引:0
作者
Horakova, Eva [1 ]
Vyskocil, Vlastimil [1 ]
Barek, Jiri [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Univ Res Ctr UNCE Supramol Chem, Dept Analyt Chem,UNESCO Lab Evironm Electchem, CZ-12843 Prague 2, Czech Republic
来源
XXXIII MODERNI ELEKTROCHEMICKE METODY | 2013年
关键词
4-Nitrobiphenyl; DC voltammetry; Differential pulse voltammetry; Adsorptive stripping differential pulse voltammetry; Mercury meniscus modified silver solid amalgam electrode; Supramolecular electrochemistry; Nitrated polycyclic aromatic hydrocarbons; POLYCYCLIC-AROMATIC-HYDROCARBONS; 4-AMINOBIPHENYL; POLAROGRAPHY; PAHS; HPLC;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A mercury meniscus modified silver solid amalgam electrode (m-AgSAE) was used as a working electrode for voltammetric study of electrochemical behavior and determination of 4-nitrobiphenyl (4-NBP). Optimal conditions for its determination in the concentration range from 2.10(-7) to 1.10(-4) mol L-1 at the m-AgSAE using DC voltammetry (DCV) and differential pulse voltammetry (DPV) were found in a mixture of 0.25 mol L-1 acetate buffer of pH 4.8 and methanol in a volume ratio of 7:3. Moreover, application of adsorptive stripping differential pulse voltammetry (AdSDPV) was tested to achieve a lower limit of quantification. The applicability of the developed methods was tested on model samples of drinking and river water.
引用
收藏
页码:68 / 72
页数:5
相关论文
共 19 条
[1]  
[Anonymous], 1974, IARC MONOGRAPHS EVAL, V4
[2]   ANALYSIS OF CHEMICAL CARCINOGENS .2. DETERMINATION OF 4-NITROBIPHENYL AND 4-AMINOBIPHENYL BY CONTROLLED-POTENTIAL COULOMETRY, DIFFERENTIAL PULSE POLAROGRAPHY AND DIFFERENTIAL PULSE VOLTAMMETRY [J].
BAREK, J ;
BERKA, A ;
MULLER, M ;
ZIMA, J .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1985, 50 (12) :2853-2862
[3]   Electrochemiluminescence determination of nitro polycyclic-aromatic hydrocarbons using HPLC separation [J].
Chen, X ;
Li, MJ ;
Yi, CQ ;
Tao, Y ;
Wang, XR .
CHROMATOGRAPHIA, 2003, 58 (9-10) :571-577
[4]   Improved GC/MS methods for measuring hourly PAH and nitro-PAH concentrations in urban particulate matter [J].
Crimmins, Bernard S. ;
Baker, Joel E. .
ATMOSPHERIC ENVIRONMENT, 2006, 40 (35) :6764-6779
[5]  
Feilberg A, 2001, ENVIRON SCI TECHNOL, V35, P108, DOI 10.1021/es990834l
[6]   Detection of nitro-polycyclic aromatic hydrocarbons in mainstream and sidestream tobacco smoke using electron monochromator-mass spectrometry [J].
Havey, Crystal D. ;
Dane, A. John ;
Abbas-Hawks, Christy ;
Voorhees, Kent J. .
ENVIRONMENTAL CHEMISTRY LETTERS, 2009, 7 (04) :331-336
[7]   1-NITROSOPYRENE - AN INTERMEDIATE IN THE METABOLIC-ACTIVATION OF 1-NITROPYRENE TO A MUTAGEN IN SALMONELLA-TYPHIMURIUM TA1538 [J].
HEFLICH, RH ;
HOWARD, PC ;
BELAND, FA .
MUTATION RESEARCH, 1985, 149 (01) :25-32
[8]   DETERMINATION OF 4-NITROBIPHENYL BY ADSORPTIVE STRIPPING SQUARE-WAVE POLAROGRAPHY [J].
HERNANDEZ, P ;
GALANESTELLA, F ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1993, 271 (02) :217-221
[9]  
JINHUI X, 2000, ANAL CHIM ACTA, V416, P111
[10]  
Lambert J., 1947, PRACTICAL CHEM