Stability Analysis of Doubly-Fed Induction Wind Generator Operating at Low Power Factor Mode

被引:0
作者
Zheng, Yanwen [1 ]
Li, Yongdong [1 ]
Chai, Jianyun [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
来源
IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS | 2008年
关键词
Wind energy; DFIG; Stability; Reactive capacity;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper presents an analysis of the reactive power capability (RPC) of doubly-fed induction generators (DFIG) system from the stability point of view. The stator flux orientated control (SFOC) is adopted in the DFIG system and the dynamics of rotor current is considered. The analytic stability of SFOC DFIG system has been deduced and verified on a 30kW DFIG system using a back-to-back converter. It is shown that the stability and damping of the SFOC DFIG system depends on the reactive component of the rotor current and band width of rotor current loop.
引用
收藏
页码:2170 / 2175
页数:6
相关论文
共 11 条
[1]  
Erlich I, 2005, IEEE POWER ENG SOC, P1253
[2]  
HELLER M, 1997, P 7 EUR C POW EL APP, V2, P707
[3]  
JING L, 2004, POWER SYSTEM TECHNOL, V28, P13
[4]   Active use of DFIG-based variable-speed wind-turbine for voltage regulation at a remote location [J].
Ko, Hee-Sang ;
Yoon, Gi-Gab ;
Hong, Won-Pyo .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (04) :1916-1925
[5]  
Liu CW, 2001, ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, P1203, DOI 10.1109/ICEMS.2001.971897
[6]   Reactive power capability of a wind turbine with doubly fed induction generator [J].
Lund, Torsten ;
Sorensen, Poul ;
Eek, Jarle .
WIND ENERGY, 2007, 10 (04) :379-394
[7]   Double-fed induction machine: converter optimisation and field oriented control without position sensor [J].
Morel, L ;
Godfroid, H ;
Mirzaian, A ;
Kauffmann, JM .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1998, 145 (04) :360-368
[8]   Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation [J].
Pena, R ;
Clare, JC ;
Asher, GM .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1996, 143 (03) :231-241
[9]   Evaluation of current control methods for wind turbines using doubly-fed induction machines [J].
Petersson, A ;
Harnefors, L ;
Thiringer, T .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (01) :227-235
[10]  
SCHREIER L, 1999, WORKING REGIONS ADJU, P457