Fluoroscopic motion study confirming the stability of a medial pivot design total knee arthroplasty

被引:65
作者
Shimmin, Andrew [1 ]
Martinez-Martos, Sara [1 ]
Owens, John [2 ]
Iorgulescu, Alex D. [3 ]
Banks, Scott [3 ]
机构
[1] Melbourne Orthopaed Grp, Windsor, Vic, Australia
[2] Olymp Pk Imaging, Melbourne, Vic, Australia
[3] Orthopaed Res Lab, W Palm Beach, FL USA
关键词
Total knee arthroplasty; Kinematics; Medial pivot; Fluoroscopy; Prosthetic design; DEEP FLEXION; IMPLANT DESIGN; KINEMATICS; RANGE; PROSTHESES; STANDARD; REPLACEMENT; STAIR;
D O I
10.1016/j.knee.2014.11.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The ideal total knee arthroplasty should provide maximum range of motion and functional stability for all desired daily activities. The SAIPH (TM) (MatOrtho; UK) knee has a medial pivot knee kinematic pattern designed to achieve medial stability and an asymmetric posterior translation of the lateral femoral condyle during knee flexion and in this way attempts to mimic the natural knee motion. This study aims to analyze knee kinematics of the SAIPH (TM) total knee arthroplasty (TKA) by videofluoroscopy during four different weightbearing activities. Methods: Fourteen consecutive patients operated on by a single surgeon, with a minimum follow-up of 24 months were included in this IRB-approved study. There were no exclusions based on patient's functional level. A medially conforming knee was implanted in all cases. Participants in the study were asked to perform the clinically relevant functional activities of pivoting, kneeling, lungeing and step-up/down activities while their knee motion was recorded by videofluoroscopy. Results: Maximum knee flexion during the kneeling activity mean 127 degrees (100 degrees-155 degrees). An asymmetric posterior translation of the lateral femoral condyle (LFC) was observed during pivoting, kneeling, lungeing and stepping. No paradoxical anterior translation of the femoral condyles was observed in any activity. Conclusion: The kinematics observed in this implant are similar in pattern, although smaller in magnitude, to normal functional knees, showing a posterior translation of the lateral femoral condyle during knee flexion, with internal rotation of the tibia, and no paradoxical anterior motion in any of the four weight bearing activities. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:522 / 526
页数:5
相关论文
共 27 条
[1]   Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[2]   Implant design affects knee arthroplasty kinematics during stair-stepping [J].
Banks, SA ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :187-193
[3]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[4]   Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[5]   Questionnaire on the perceptions of patients about total knee replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Murray, D ;
Carr, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :63-69
[6]  
Dennis DA, 1998, CLIN ORTHOP RELAT R, P47
[7]   In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics [J].
Dennis, DA ;
Mahfouz, MR ;
Komistek, RD ;
Hoff, W .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :241-253
[8]   Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752
[9]   The movement of the normal tibio-femoral joint [J].
Freeman, MAR ;
Pinskerova, V .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :197-208
[10]   Knee Arthroplasty With a Medially Conforming Ball-and-Socket Tibiofemoral Articulation Provides Better Function [J].
Hossain, Fahad ;
Patel, Shelain ;
Rhee, Shin-Jae ;
Haddad, Fares Sami .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (01) :55-63