A novel approach to the quantitative detection of anabolic steroids in bovine muscle tissue by means of a hybrid quadrupole time-of-flight-mass spectrometry instrument

被引:15
作者
Bussche, Julie Vanden [1 ]
Decloedt, Anneleen [1 ]
Van Meulebroek, Lieven [1 ]
De Clercq, Nathalie [1 ]
Lock, Stephen [2 ]
Stahl-Zeng, Jianru [2 ]
Vanhaecke, Lynn [1 ]
机构
[1] Univ Ghent, Fac Vet Med, Dept Vet Publ Hlth & Food Safety, Chem Anal Lab, B-9820 Merelbeke, Belgium
[2] AB Sciex UK, Tech Support, Warrington WA1 1RX, Cheshire, England
关键词
Anabolic steroids; Hybrid MS instrument; MicroLC; Chemometric analysis sample extraction; CD; 2002/657/EC; LIQUID-CHROMATOGRAPHY; GROWTH PROMOTERS; RESIDUE ANALYSIS; CONFIRMATION; VALIDATION; ORBITRAP; PLASMA; QUANTIFICATION; BIOANALYSIS; PROTEINS;
D O I
10.1016/j.chroma.2014.07.087
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In recent years, the analysis of veterinary drugs and growth-promoting agents has shifted from target-oriented procedures, mainly based on liquid chromatography coupled to triple-quadrupole mass spectrometry (LC-QqQ-MS), towards accurate mass full scan MS (such as Time-of-Flight (ToF) and Fourier Transform (FT)-MS). In this study, the performance of a hybrid analysis instrument (i.e. UHPLC-QuadrupoleTime-of-Flight-MS (QqToF-MS)), able to exploit both full scan HR and MS/MS capabilities within a single analytical platform, was evaluated for confirmatory analysis of anabolic steroids (gestagens, estrogens including stilbenes and androgens) in meat. The validation data was compared to previously obtained results (CD 2002/657/EC) for QqQ-MS and single stage Orbitrap-MS. Additionally, a fractional factorial design was used to shorten and optimize the sample extraction. Validation according to CD 2002/657/EC demonstrated that steroid analysis using QqToF has a higher competing value towards QqQ-MS in terms of selectivity/specificity, compared to single stage Orbitrap-MS. While providing excellent linearity, based on lack-of-fit calculations (F-test, alpha = 0.05 for all steroids except 17 beta-ethinylestradiol: alpha = 0.01), the sensitivity of QqToF-MS proved for 61.8% and 85.3% of the compounds more sensitive compared to QqQ-MS and Orbitrap-MS, respectively. Indeed, the CC alpha values, obtained upon ToF-MS/MS detection, ranged from 0.02 to 1.74 mu g kg(-1) for the 34 anabolic steroids, while for QqQ-MS and Orbitrap-MS values ranged from 0.04 to 0.88 mu g kg(-1) and from 0.07 to 2.50 mu g kg-1, respectively. Using QqToF-MS and QqQ-MS, adequate precision was obtained as relative standard deviations for repeatability and within-laboratory reproducibility, were below 20%. In case of Orbitrap-MS, some compounds (i.e. some estrogens) displayed poor precision, which was possibly caused by some lack of sensitivity at lower concentrations and the absence of MRM-like experiments. Overall, it can be concluded that QqToF-MS offers good quantitative and confirmatory performance using the ToF-MS/MS mode whereas the full scan HR-ToF-MS allows screening for potential new designer drugs. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:229 / 239
页数:11
相关论文
共 37 条
  • [1] Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
    Anderson, L
    Hunter, CL
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) : 573 - 588
  • [2] Validation of analytical methods based on mass spectrometric detection according to the "2002/657/EC" European decision: guideline and application
    Antignac, JP
    Le Bizec, B
    Monteau, F
    Andre, F
    [J]. ANALYTICA CHIMICA ACTA, 2003, 483 (1-2) : 325 - 334
  • [3] Analysis of meat samples for anabolic steroids residues by liquid chromatography/tandem mass spectrometry
    Blasco, Cristina
    Van Poucke, Christof
    Van Peteghem, Carlos
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 230 - 239
  • [4] Investigations of the microbial transformation of cortisol to prednisolone in urine samples
    Bredehoeft, Michael
    Baginski, Rainer
    Parr, Maria-Kristina
    Thevis, Mario
    Schaenzer, Wilhelm
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2012, 129 (1-2) : 54 - 60
  • [5] Development and validation of an UPLC-MS/MS method for the determination of ionophoric and synthetic coccidiostats in vegetables
    Broekaert, N.
    Van Peteghem, C.
    Daeseleire, E.
    Sticker, D.
    Van Poucke, C.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (10) : 3335 - 3344
  • [6] Matrix effects on accurate mass measurements of low-molecular weight compounds using liquid chromatography-electrospray-quadrupole time-of-flight mass spectrometry
    Calbiani, F
    Careri, M
    Elviri, L
    Mangia, A
    Zagnoni, I
    [J]. JOURNAL OF MASS SPECTROMETRY, 2006, 41 (03): : 289 - 294
  • [7] Effects of low-dose dexamethasone and prednisolone long term administration in beef calf: Chemical and morphological investigation
    Cannizzo, Francesca Tiziana
    Capra, Pierluigi
    Divari, Sara
    Ciccotelli, Valentina
    Biolatti, Bartolomeo
    Vincenti, Marco
    [J]. ANALYTICA CHIMICA ACTA, 2011, 700 (1-2) : 95 - 104
  • [8] Chen HH, 2009, CHINESE J ANAL CHEM, V37, P181
  • [9] An introduction to quadrupole-time-of-flight mass spectrometry
    Chernushevich, IV
    Loboda, AV
    Thomson, BA
    [J]. JOURNAL OF MASS SPECTROMETRY, 2001, 36 (08): : 849 - 865
  • [10] Theoretical analysis of chromatographic peak asymmetry and sharpness by the moment method using two peptides
    Choi, DY
    Row, KH
    [J]. BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2004, 9 (06) : 495 - 499