Repeatability of small lung nodule measurement in low-dose lung screening: a phantom study

被引:3
作者
Du, Yu [1 ]
Shi, Gao-Feng [1 ]
Wang, Ya-Ning [1 ]
Wang, Qi [1 ]
Feng, Hui [1 ]
机构
[1] Hebei Med Univ, Dept Radiol, Hosp 4, 12 Jiankang Rd, Shijiazhuang 050011, Hebei, Peoples R China
关键词
Computer tomography; Low dose; Pulmonary nodules; Body model; Lung cancer; SMALL PULMONARY NODULES; CT; ACCURACY; GUIDELINES; MANAGEMENT; PATTERNS;
D O I
10.1186/s12880-020-00510-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Lung cancer screening revealed that people with small pulmonary nodules are mostly asymptomatic and that some of these people are at risk of developing lung cancer, so we intended to explore the repeatability of small lung nodule measurement in low-dose lung screening. Methods We scanned eight ground-glass nodules (GGNs) and solid nodules, with diameters of 3, 5, 8, and 10 mm. They were divided according to the different combination schemes of tube voltage (KV) and tube current (mA) as 70, 80, 100, and 120 KV, and currents of nine tubes were divided as 20, 30, 40, 50, 60, 70, 80, 90, and 100 mAs. Results Compared with the conventional dose group (120 kVp, 100 mAs), the nodule diameter and solid nodule volume measured by all scanning combinations were more consistent (P > 0.05), the volumes of 10 mm GGNs combinations were consistent (P > 0.05), the volumes of 8 mm GGNs were consistent (P > 0.05), the volumes of 5 mm GGNs combinations were consistent (P > 0.05), and the volumes of 3 mm were consistent (P > 0.05). Conclusion In lung cancer screening, CT parameters should be as follows: tube voltage is more than 80 kVp, and tube current is 80 mAs in order to meet the requirements for the accurate measurement of the diameter and volume of pulmonary nodules.
引用
收藏
页数:9
相关论文
共 19 条
[1]   Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]   British Thoracic Society guidelines for the investigation and management of pulmonary nodules [J].
Callister, M. E. J. ;
Baldwin, D. R. ;
Akram, A. R. ;
Barnard, S. ;
Cane, P. ;
Draffan, J. ;
Franks, K. ;
Gleeson, F. ;
Graham, R. ;
Malhotra, P. ;
Prokop, M. ;
Rodger, K. ;
Subesinghe, M. ;
Waller, D. ;
Woolhouse, I. .
THORAX, 2015, 70 :1-54
[3]   Developing a radiograher reporting service for CT lung nodule surveillance [J].
Carey, N. ;
Miller, F. ;
Bunn, L. .
LUNG CANCER, 2018, 115 :S24-S24
[4]   Accuracy of low-dose computed tomography (CT) for detecting and characterizing the most common CT-patterns of pulmonary disease [J].
Christe, Andreas ;
Charimo-Torrente, Jaled ;
Roychoudhury, Kingshuk ;
Vock, Peter ;
Roos, Justus E. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (03) :E142-E150
[5]   CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT [J].
Christe, Andreas ;
Lin, Margaret C. ;
Yen, Andrew C. ;
Hallett, Rich L. ;
Roychoudhury, Kingshuk ;
Schmitzberger, Florian ;
Fleischmann, Dominik ;
Leung, Ann N. ;
Rubin, Geoffry D. ;
Vock, Peter ;
Roos, Justus E. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) :2860-2866
[6]   Lung-RADS Category 4X: Does It Improve Prediction of Malignancy in Subsolid Nodules? [J].
Chung, Kaman ;
Jacobs, Colin ;
Scholten, Ernst T. ;
Goo, Jin Mo ;
Prosch, Helmut ;
Sverzellati, Nicola ;
Ciompi, Francesco ;
Mets, Onno M. ;
Gerke, Paul K. ;
Prokop, Mathias ;
van Ginneken, Bram ;
Schaefer-Prokop, Cornelia M. .
RADIOLOGY, 2017, 284 (01) :264-271
[7]   Results of Initial Low-Dose Computed Tomographic Screening for Lung Cancer [J].
Church, Timothy R. ;
Black, William C. ;
Aberle, Denise R. ;
Berg, Christine D. ;
Clingan, Kathy L. ;
Duan, Fenghai ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gierada, David S. ;
Jones, Gordon C. ;
Mahon, Irene ;
Marcus, Pamela M. ;
Sicks, JoRean D. ;
Jain, Amanda ;
Baum, Sarah .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (21) :1980-1991
[8]   Lung CT Screening Reporting and Data System Speed and Accuracy Are Increased With the Use of a Semiautomated Computer Application [J].
Clark, Toshimasa J. ;
Flood, Thomas F. ;
Maximin, Suresh T. ;
Sachs, Peter B. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (12) :1301-1306
[9]   Evaluation of Individuals With Pulmonary Nodules: When Is It Lung Cancer? Diagnosis and Management of Lung Cancer, 3rd ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines [J].
Gould, Michael K. ;
Donington, Jessica ;
Lynch, William R. ;
Mazzone, Peter J. ;
Midthun, David E. ;
Naidich, David P. ;
Wiener, Renda Soylemez .
CHEST, 2013, 143 (05) :E93-E120
[10]   Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecifi ed analysis of data from the NELSON trial of low-dose CT screening [J].
Horeweg, Nanda ;
van Rosmalen, Joost ;
Heuvelmans, Marjolein A. ;
van der Aalst, Carlijn M. ;
Vliegenthart, Rozemarijn ;
Scholten, Ernst Th ;
ten Haaf, Kevin ;
Nackaerts, Kristiaan ;
Lammers, Jan-Willem J. ;
Weenink, Carla ;
Groen, Harry J. ;
van Ooijen, Peter ;
de Jong, Pim A. ;
de Bock, Geertruida H. ;
Mali, Willem ;
de Koning, Harry J. ;
Oudkerk, Matthijs .
LANCET ONCOLOGY, 2014, 15 (12) :1332-1341