High bacterial contamination rate of electrocautery tips during total hip and knee arthroplasty

被引:11
作者
Abdelaziz, Hussein [1 ]
Zahar, Akos [1 ]
Lausmann, Christian [1 ]
Gehrke, Thorsten [1 ]
Fickenscher, Helmut [2 ]
Suero, Eduardo M. [3 ]
Gebauer, Matthias [4 ]
Citak, Mustafa [1 ]
机构
[1] Helios ENDO Klin, Dept Orthopaed Surg, Holstenstr 2, D-22767 Hamburg, Germany
[2] Univ Kiel, Inst Infect Med, Kiel, Germany
[3] Hannover Med Sch, Trauma Dept, Hannover, Germany
[4] Roland Klin Bremen, Dept Orthopaed Surg, Bremen, Germany
关键词
Electrocautery tips; Periprosthetic joint infection (PJI); Surgical site infection (SSI); Intra-operative contamination; Bacterial; Total knee arthroplasty; Total hip arthroplasty; PERIPROSTHETIC JOINT INFECTION; SURGERY;
D O I
10.1007/s00264-018-3822-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of the study was to quantify the bacterial contamination rate of electrocautery tips during primary total joint replacement (TJR), as well as during aseptic and septic revision TJR. Methods A total of 150 electrocautery tips were collected between April and July 2017. TJR surgeries were divided into three groups: (1) primary, (2) aseptic and (3) septic revisions. In each group, a total of 50 electrocautery tips were collected. A monopolar electrocautery with a reusable stainless-steel blade tip was used in all cases. The rate of bacterial contamination was determined for all groups. Correlation of exposure time and type of surgery was analyzed. Results The overall bacterial contamination rate was 14.7% (95% CI 9.4 to 21.4%). The highest contamination rate occurred in the septic revision group (30.0%; 95% CI 17.9 to 44.6%), followed by the primary cases group (10.0%; 95% CI 3.3 to 21.8%) and the aseptic revision group (4.0%; 95% CI 0.5 to 13.7%). Exposure time did not affect the bacterial contamination rate. In 12 out of 15 (80%) contaminations identified in the septic group, we found the same causative microorganism of the prosthetic joint infection on the electrocautery tip. Conclusions The bacterial contamination of the electrocautery tips is relatively high, especially during septic hip revision arthroplasty. Electrocautery tips should be changed after debridement of infected tissue.
引用
收藏
页码:755 / 760
页数:6
相关论文
共 18 条
[1]   BACTERIAL TRANSFERENCE DURING ELECTRODESICCATION AND ELECTROCOAGULATION [J].
BENNETT, RG ;
KRAFFERT, CA .
ARCHIVES OF DERMATOLOGY, 1990, 126 (06) :751-755
[2]   Intraoperative bacterial contamination in operations for joint replacement [J].
Davis, N ;
Curry, A ;
Gambhir, AK ;
Panigrahi, H ;
Walker, CRC ;
Wilkins, EGL ;
Worsley, MA ;
Kay, PR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :886-889
[3]   Contamination of the Surgical Field with Propionibacterium acnes in Primary Shoulder Arthroplasty [J].
Falconer, Travis M. ;
Baba, Mohammed ;
Dorrestijn, Oscar ;
Donaldson, Matthew J. ;
Smith, Margaret M. ;
Figtree, Melanie C. ;
Hudson, Bernard J. ;
Cass, Benjamin ;
Young, Allan A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (20) :1722-1728
[4]   Periprosthetic joint infection by Propionibacterium acnes: Clinical differences between monomicrobial versus polymicrobial infection [J].
Figa, Raul ;
Muneton, David ;
Gomez, Lucia ;
Matamala, Alfredo ;
Lung, Mayli ;
Cuchi, Eva ;
Corona, Pablo S. .
ANAEROBE, 2017, 44 :143-149
[5]  
Frowen P., 2010, Neale's disorders of the foot clinical companion
[6]   Complete Eradication of Biofilm From Orthopedic Materials [J].
Leary, Jeffrey T. ;
Werger, Matthew M. ;
Broach, William H. ;
Shaw, Lindsey N. ;
Santoni, Brandon G. ;
Bernasek, Thomas L. ;
Lyons, Steven T. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (08) :2513-2518
[7]   Guideline for Prevention of Surgical Site Infection, 1999 [J].
Mangram, AJ ;
Horan, TC ;
Pearson, ML ;
Silver, LC ;
Jarvis, WR .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1999, 20 (04) :250-278
[8]   Risk of Contamination in Assembled vs Disassembled Instruments in Hip Arthroplasty Surgery [J].
Mayer, Ryan R. ;
Bederman, S. Samuel ;
Colin, Vincent M. ;
Berger, Martina M. ;
Cesario, Thomas C. ;
Schwarzkopf, Ran .
JOURNAL OF ARTHROPLASTY, 2016, 31 (08) :1746-1749
[9]   Clinical Analysis of Propionibacterium acnes Infection After Total Knee Arthroplasty [J].
Nodzo, Scott R. ;
Westrich, Geoffrey H. ;
Henry, Michael W. ;
Miller, Andy O. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (09) :1986-1989
[10]   No need to change the skin knife in modern arthroplasty surgery [J].
Ottesen, C. ;
Skovby, A. ;
Troelsen, A. ;
Specht, C. ;
Friis-Moller, A. ;
Husted, H. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (08) :1163-1166