Intra-operative MRI at 3.0 Tesla: A Moveable Magnet

被引:5
作者
Lang, Michael J. [1 ]
Greer, Alexander D. [1 ]
Sutherland, Garnette R. [1 ]
机构
[1] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
来源
INTRAOPERATIVE IMAGING | 2011年 / 109卷
关键词
3.0-Tesla; Intra-operative imaging; Magnetic resonance imaging; Neurosurgery; NEUROSURGERY;
D O I
10.1007/978-3-211-99651-5_23
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper presents the development and implementation of an intra-operative magnetic resonance imaging (ioMRI) program using a moveable 3.0 T magnet with a large working aperture. Methods: A previously established prototype 1.5 T ioMRI program based on a ceiling-mounted moveable magnet was upgraded to 3.0 T. The upgrade included a short, 1.73 m, magnet with a large 70 cm working aperture (IMRIS, Winnipeg, Canada), whole-room radio-frequency shielding, and a fully functional MR-compatible operating room (OR) table. Between January and September 2009, 100 consecutive patients were evaluated at 3.0 T. Results: The ioMRI upgrade maintained a patient-focused environment. When not needed for surgery, the magnet was moved to an adjacent room. A large aperture and streamlined OR table allowed freedom of patient positioning while maintaining access and visibility. Working at 3.0 T enabled application of advanced imaging sequences to the full spectrum of neurosurgical pathology in the ioMRI environment. The use of ioMRI continues to show unsuspected residual tumor in up to 20% of cases. There were no adverse events or technical system failures. Conclusion: An ioMRI program based a 3.0 T moveable magnet is feasible. By moving the magnet, the system maintains a patient-focused surgical environment and the ability to share the technology between medical disciplines.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 18 条
[1]   Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications [J].
Black, PM ;
Moriarty, T ;
Alexander, E ;
Stieg, P ;
Woodard, EJ ;
Gleason, PL ;
Martin, CH ;
Kikinis, R ;
Schwartz, RB ;
Jolesz, FA .
NEUROSURGERY, 1997, 41 (04) :831-842
[2]  
Field Aaron S, 2004, Top Magn Reson Imaging, V15, P315, DOI 10.1097/00002142-200410000-00004
[3]   Novel, compact, intraoperative magnetic resonance imaging-guided system for conventional neurosurgical operating rooms [J].
Hadani, M ;
Spiegelman, R ;
Feldman, Z ;
Berkenstadt, H ;
Ram, Z .
NEUROSURGERY, 2001, 48 (04) :799-807
[4]   3-Tesla functional magnetic resonance imaging-guided tumor resection [J].
Hall, Walter A. ;
Truwit, Charles L. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 (04) :223-230
[5]   IMPACT OF INTRAOPERATIVE HIGH-FIELD MAGNETIC RESONANCE IMAGING GUIDANCE ON GLIOMA SURGERY: A PROSPECTIVE VOLUMETRIC ANALYSIS [J].
Hatiboglu, Mustafa Aziz ;
Weinberg, Jeffrey S. ;
Suki, Dima ;
Rao, Ganesh ;
Prabhu, Sujit S. ;
Shah, Komal ;
Jackson, Ed ;
Sawaya, Raymond .
NEUROSURGERY, 2009, 64 (06) :1073-1081
[6]   Intraoperative magnetic resonance imaging at 3-t using a dual independent operating room-magnetic resonance imaging suite: Development, feasibility, safety, and preliminary experience [J].
Jankovski, Aleksandar ;
Francotte, Frederic ;
Vaz, Geraldo ;
Fomekong, Edward ;
Duprez, Thierry ;
Van Boven, Michel ;
Docquier, Marie-Agnes ;
Hermoye, Laurent ;
Cosnard, Guy ;
Raftopoulos, Christian .
NEUROSURGERY, 2008, 63 (03) :412-424
[7]  
Kaibara T, 2000, NEUROSURGERY, V47, P131
[8]  
Lin Weili, 2003, Magn Reson Imaging Clin N Am, V11, P615, DOI 10.1016/S1064-9689(03)00068-0
[9]   Brain tumor resection: Intraoperative monitoring with high-field-strength MR imaging-initial results [J].
Martin, AJ ;
Hall, WA ;
Liu, HY ;
Pozza, CH ;
Michel, E ;
Casey, SO ;
Maxwell, RE ;
Truwit, CL .
RADIOLOGY, 2000, 215 (01) :221-228
[10]   Low-field magnetic resonance imaging for intraoperative use in neurosurgery: a 5-year experience [J].
Nimsky, C ;
Ganslandt, O ;
Tomandl, B ;
Buchfelder, M ;
Fahlbusch, R .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2690-2703