NURBS modeling and structural shape optimization of cardiovascular stents

被引:18
作者
Clune, Rory [1 ]
Kelliher, Denis [2 ]
Robinson, James C. [3 ]
Campbell, John S. [3 ]
机构
[1] MIT, Cambridge, MA 02139 USA
[2] Natl Univ Ireland Univ Coll Cork, Cork, Ireland
[3] Kepler Engn Software Ltd, Natl Software Ctr, Cork, Ireland
关键词
Cardiovascular stents; Structural shape optimization; NURBS; MECHANICAL-BEHAVIOR; DESIGN;
D O I
10.1007/s00158-013-1038-y
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cardiovascular stents have been used since the 1990s to treat atherosclerosis, one of leading causes of death in the western world, and structural optimization has led to significant improvements in stent performance. Much of the potential variation in stent geometry, however, has remained unconsidered. This paper presents a non-uniform rational basis spline (NURBS) parameterization of a stent, the inclusion of structural fatigue resistance as a design consideration, and the results of a design optimization based on response surface techniques. Results show the feasibility and merits of the NURBS approach, which models a much broader range of shapes than was previously possible. Multi-objective optimization produces a range of geometrically diverse Pareto-optimal designs; these can be used to develop future clinical design guides, accounting for the variation observed across patients. We conclude by motivating future work with increasingly complex physical modeling and optimization capabilities.
引用
收藏
页码:159 / 168
页数:10
相关论文
共 26 条
[1]  
[Anonymous], DACE MATLAB KRIGING
[2]   Robust optimization of cardiovascular stents: A comparison of methods [J].
Atherton, MA ;
Bates, RA .
ENGINEERING OPTIMIZATION, 2004, 36 (02) :207-217
[3]  
Balcon R, 1997, EUR HEART J, V18, P1536
[4]   In-stent stenosis: pathology and implications for the development of drug eluting stents [J].
Bennett, MR .
HEART, 2003, 89 (02) :218-224
[5]   A fast and elitist multiobjective genetic algorithm: NSGA-II [J].
Deb, K ;
Pratap, A ;
Agarwal, S ;
Meyarivan, T .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2002, 6 (02) :182-197
[6]  
Duggan TV, 1977, FATIGUE DESIGN CRITE, V77
[7]   Mechanical behaviour modelling of balloon-expandable stents [J].
Dumoulin, C ;
Cochelin, B .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1461-1470
[8]   Mechanical properties of coronary stents determined by using finite element analysis [J].
Etave, F ;
Finet, G ;
Boivin, M ;
Boyer, JC ;
Rioufol, G ;
Thollet, G .
JOURNAL OF BIOMECHANICS, 2001, 34 (08) :1065-1075
[9]  
Harewood F, 2011, ALT PROD DES WORKSH
[10]  
Hastie T., 2009, ELEMENTS STAT LEARNI, DOI DOI 10.1007/978-0-387-84858-7