Real-World Data from the First US Commercial Users of an Implantable Continuous Glucose Sensor

被引:30
作者
Sanchez, Patricia [1 ]
Ghosh-Dastidar, Samanwoy [1 ]
Tweden, Katherine S. [1 ]
Kaufman, Francine R. [1 ]
机构
[1] Senseon Inc, 20451 Seneca Meadows Pkwy, Germantown, MD 20876 USA
关键词
Continuous glucose monitoring; Implantable sensor; Type; 1; diabetes; 2; Glucometrics; Safety; PROSPECTIVE MULTICENTER EVALUATION; INSULIN-PUMP THERAPY; ACCURACY; INJECTIONS; PRECISE; DIAMOND; SAFETY; ADULTS;
D O I
10.1089/dia.2019.0234
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The Eversense (R) Continuous Glucose Monitoring (CGM) System, with the first 90-day implantable sensor, received FDA (Food and Drug Administration) approval in June 2018. No real-world experience has been published. Methods: Deidentified sensor glucose (SG) data from August 1, 2018 to May 11, 2019 in the Eversense Data Management System (DMS) were analyzed for the first 205 patients who reached a 90-day wear period on the Eversense CGM system. The mean SG, standard deviation (SD), median interquartile range, coefficient of variation (CV), glucose measurement index (GMI), and percent and time in minutes across glucose ranges were computed for the 24-h time period, the nighttime (00:00-06:00), and by 30-day wear periods. Sensor accuracy, sensor reinsertion rate, transmitter wear time, and safety data were assessed. Results: Of the 205 patients, 129 identified as type 1, 18 as type 2, and 58 were unreported. Fifty were CGM naive, 112 had prior CGM experience, and 43 were unreported. The mean SG was 161.8 mg/dL, SD was 57.4 mg/dL, CV was 0.35, and GMI was 7.18%. Percent SG at <54 mg/dL was 1.2% (18 min), <70 mg/dL was 4.1% (59.7 min), time in range (>= 70-180 mg/dL) was 62.3% (897.7 min), >180-250 mg/dL was 21.9% (315.8 min), and >250 mg/dL was 11.6% (166.7 min). Nighttime values were similar. The glucometric values were similar over 30-day time periods of the sensor wear. The mean absolute relative difference (SD) using 27,708 calibration paired points against home blood glucose meters was 11.2% (11.3%). The sensor reinsertion rate was 78.5%. The median transmitter wear time was 83.6%. There were no related serious adverse events. Conclusion: The Eversense real-world data showed promising glycemic results, sensor accuracy, and safety. These data suggest that the Eversense CGM system is a valuable tool for diabetes management.
引用
收藏
页码:677 / 681
页数:5
相关论文
共 23 条
[1]  
Barnard Katharine D, 2018, J Diabetes Sci Technol, V12, P634, DOI 10.1177/1932296817735123
[2]   The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial [J].
Battelino, T. ;
Conget, I. ;
Olsen, B. ;
Schuetz-Fuhrmann, I. ;
Hommel, E. ;
Hoogma, R. ;
Schierloh, U. ;
Sulli, N. ;
Bolinder, J. .
DIABETOLOGIA, 2012, 55 (12) :3155-3162
[3]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[4]   Effect of initiating use of an insulin pump in adults with type 1 diabetes using multiple daily insulin injections and continuous glucose monitoring (DIAMOND): a multicentre, randomised controlled trial [J].
Beck, Roy W. ;
Riddlesworth, Tonya D. ;
Ruedy, Katrina J. ;
Kollman, Craig ;
Ahmann, Andrew J. ;
Bergenstal, Richard M. ;
Bhargava, Anuj ;
Bode, Bruce W. ;
Haller, Stacie ;
Kruger, Davida F. ;
McGill, Janet B. ;
Polonsky, William ;
Price, David ;
Toschi, Elena .
LANCET DIABETES & ENDOCRINOLOGY, 2017, 5 (09) :700-708
[5]   Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections The DIAMOND Randomized Clinical Trial [J].
Beck, Roy W. ;
Riddlesworth, Tonya ;
Ruedy, Katrina ;
Ahmann, Andrew ;
Bergenstal, Richard ;
Haller, Stacie ;
Kollman, Craig ;
Kruger, Davida ;
McGill, Janet B. ;
Polonsky, William ;
Toschi, Elena ;
Wolpert, Howard ;
Price, David .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04) :371-378
[6]   Glucose Management Indicator (GMI): A New Term for Estimating A1C From Continuous Glucose Monitoring [J].
Bergenstal, Richard M. ;
Beck, Roy W. ;
Close, Kelly L. ;
Grunberger, George ;
Sacks, David B. ;
Kowalski, Aaron ;
Brown, Adam S. ;
Heinemann, Lutz ;
Aleppo, Grazia ;
Ryan, Donna B. ;
Riddlesworth, Tonya D. ;
Cefalu, William T. .
DIABETES CARE, 2018, 41 (11) :2275-2280
[7]   Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Garg, Satish ;
Weinzimer, Stuart A. ;
Buckingham, Bruce A. ;
Bode, Bruce W. ;
Tamborlane, William V. ;
Kaufman, Francine R. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13) :1407-1408
[8]   Threshold-Based Insulin-Pump Interruption for Reduction of Hypoglycemia [J].
Bergenstal, Richard M. ;
Klonoff, David C. ;
Garg, Satish K. ;
Bode, Bruce W. ;
Meredith, Melissa ;
Slover, Robert H. ;
Ahmann, Andrew J. ;
Welsh, John B. ;
Lee, Scott W. ;
Kaufman, Francine R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (03) :224-232
[9]  
Bergenstal Richard M, 2013, J Diabetes Sci Technol, V7, P562
[10]   Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Tamborlane, William V. ;
Ahmann, Andrew ;
Buse, John B. ;
Dailey, George ;
Davis, Stephen N. ;
Joyce, Carol ;
Peoples, Tim ;
Perkins, Bruce A. ;
Welsh, John B. ;
Willi, Steven M. ;
Wood, Michael A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04) :311-320