Assessment of Dry Epidermal Electrodes for Long-Term Electromyography Measurements

被引:40
作者
Yamagami, Momona [1 ]
Peters, Keshia M. [2 ]
Milovanovic, Ivana [2 ]
Kuang, Irene [3 ]
Yang, Zeyu [4 ]
Lu, Nanshu [5 ]
Steele, Katherine M. [2 ]
机构
[1] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[4] Chengdu Rotex Technol Co Ltd, Chengdu 610041, Peoples R China
[5] Univ Texas Austin, Dept Biomed Engn Aerosp Engn & Engn Mech, Austin, TX 78712 USA
基金
美国国家卫生研究院;
关键词
neurological injury; stroke rehabilitation; impedance measurements; Jebsen Taylor Hand Function Test; Box & Block; signal-to-noise ratio; SURFACE ELECTROMYOGRAPHY; RELIABILITY;
D O I
10.3390/s18041269
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Commercially available electrodes can only provide quality surface electromyography (sEMG) measurements for a limited duration due to user discomfort and signal degradation, but in many applications, collecting sEMG data for a full day or longer is desirable to enhance clinical care. Few studies for long-term sEMG have assessed signal quality of electrodes using clinically relevant tests. The goal of this research was to evaluate flexible, gold-based epidermal sensor system (ESS) electrodes for long-term sEMG recordings. We collected sEMG and impedance data from eight subjects from ESS and standard clinical electrodes on upper extremity muscles during maximum voluntary isometric contraction tests, dynamic range of motion tests, the Jebsen Taylor Hand Function Test, and the Box & Block Test. Four additional subjects were recruited to test the stability of ESS signals over four days. Signals from the ESS and traditional electrodes were strongly correlated across tasks. Measures of signal quality, such as signal-to-noise ratio and signal-to-motion ratio, were also similar for both electrodes. Over the four-day trial, no significant decrease in signal quality was observed in the ESS electrodes, suggesting that thin, flexible electrodes may provide a robust tool that does not inhibit movement or irritate the skin for long-term measurements of muscle activity in rehabilitation and other applications.
引用
收藏
页数:15
相关论文
共 43 条
[1]   Evaluating Sign Language Recognition Using the Myo Armband [J].
Abreu, Joao Gabriel ;
Teixeira, Joao Marcelo ;
Figueiredo, Lucas Silva ;
Teichrieb, Veronica .
2016 18TH SYMPOSIUM ON VIRTUAL AND AUGMENTED REALITY (SVR 2016), 2016, :64-70
[2]   Multiple wearable sensors in parkinson and huntington disease individuals: A pilot study in clinic and at home [J].
Adams, Jamie L. ;
Dinesh, Karthik ;
Xiong, Mulin ;
Tarolli, Christopher G. ;
Sharma, Saloni ;
Sheth, Nirav ;
Aranyosi, A.J. ;
Zhu, William ;
Goldenthal, Steven ;
Biglan, Kevin M. ;
Dorsey, E. Ray ;
Sharma, Gaurav .
Digital Biomarkers, 2017, 1 (01) :52-63
[3]  
Albulbul Anas, 2016, Bioengineering-Basel, V3, DOI 10.3390/bioengineering3030020
[4]  
Amatanon V, 2014, 2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON)
[5]   Graphene Electronic Tattoo Sensors [J].
Ameri, Shideh Kabiri ;
Ho, Rebecca ;
Jang, Hongwoo ;
Tao, Li ;
Wang, Youhua ;
Wang, Liu ;
Schnyer, David M. ;
Akinwande, Deji ;
Lu, Nanshu .
ACS NANO, 2017, 11 (08) :7634-7641
[6]  
[Anonymous], BIOMEDICAL ENG HDB
[7]  
[Anonymous], 2015, P INT C NEW INT MUS
[8]  
[Anonymous], P 2016 IEEE W NEW YO
[9]  
[Anonymous], MUSCLES ALIVE THEIR
[10]  
[Anonymous], 1997, J ELECTROMYOGR KINES, V7, pI, DOI DOI 10.1016/S1050-6411(97)90001-8