High spatial resolution modal identification of a stadium suspension roof: Assessment of the estimates uncertainty and of modal contributions

被引:18
作者
Diord, Sandro [1 ]
Magalhaes, Filipe [1 ]
Cunha, Alvaro [1 ]
Caetano, Elsa [1 ]
机构
[1] Univ Porto, Fac Engn, Construct ViBest, Rua Dr Roberto Fries,S-N, P-4200465 Oporto, Portugal
关键词
Operational modal analysis; Maximum likelihood; Multi-setups; Confidence intervals; Modal contributions; STOCHASTIC SUBSPACE IDENTIFICATION; PARAMETERS;
D O I
10.1016/j.engstruct.2016.12.060
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In Operational Modal Analysis (OMA) engineers are usually confronted With the challenge of extracting as much information as possible from the data collected in ambient vibration tests in order to characterize the modal behaviour of the tested structures under environmental and operational conditions. There exist several tools for this purpose that combined can be used to estimate valuable information regarding modal behaviour of the tested structures from the output vibration responses measured in these tests. In this context, this paper describes the strategies and techniques employed, as well as the results obtained from the OMA performed to identify the modal properties of a football stadium suspension roof. The main focus of the paper is the employment of state-of-the-art identification techniques, in time and frequency domain, in order to estimate the modal parameters of the roof structure with high spatial resolution for the mode shapes of vibration together with their uncertainties bounds, as well as to assess the contribution of the identified modes to the measured responses under different environmental and operational conditions. A particular challenge of the presented example is the need to simultaneously process a large number of time series (15 datasets with 12 sensors - 180 time series). At the end of the paper, the estimates provided by the ambient vibration test are compared with the ones obtained with a permanent monitoring system operating during one year, in order to evaluate the representativeness of the results provided by a single ambient vibration test. (C) 2016 Published by Elsevier Ltd.
引用
收藏
页码:117 / 135
页数:19
相关论文
共 26 条
[1]  
Amador S, 2013, 5 INT OP MOD AN C GU
[2]  
Amador S, 2011, P EXP VIBR AN CIV EN, V2
[3]  
[Anonymous], 2000, SYSTEM IDENTIFICATIO
[4]  
Caetano E, 2000, J STRUCT INFRASTRUCT, V6, P715
[5]  
Caetano E., 2001, Numerical modelling of the Structural Behaviour of the New Braga Stadium Roof
[6]   Uncertainty quantification for modal parameters from stochastic subspace identification on multi-setup measurements [J].
Doehler, Michael ;
Lam, Xuan-Binh ;
Mevel, Laurent .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2013, 36 (02) :562-581
[7]  
El-Kafafy M., 2013, THESIS
[8]  
El-Kafafy M, 2012, P 19 INT MOD AN C IM
[9]  
El-Kafafy M, 2012, P 16 IFAC S SYST ID
[10]  
Furtado R., 2005, Structural Engineering International, V15, P72, DOI DOI 10.2749/101686605777963143