Validity of a new optic disc grading software for use in clinical and epidemiological research

被引:9
作者
Tham, Yih-Chung [1 ,2 ]
Cheung, Carol Y. [1 ,2 ,5 ]
Wong, Tien Y. [1 ,2 ]
Baskaran, Mani [1 ,2 ]
Liu, Jiang [6 ]
Lee, Beng-Hai [6 ]
Yin, Fengshou [6 ]
Wong, Damon W. K. [6 ]
Wang, Jie Jin [7 ]
Mitchell, Paul [7 ]
Aung, Tin [1 ,2 ]
Cheng, Ching-Yu [1 ,2 ,3 ,4 ,5 ]
机构
[1] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[2] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Ophthalmol, Singapore 117595, Singapore
[3] Natl Univ Singapore, Saw Swee Hock Sch Publ Hlth, Singapore 117548, Singapore
[4] Natl Univ Hlth Syst, Singapore, Singapore
[5] Duke NUS Grad Med Sch, Off Clin Sci, Ctr Quantitat Med, Singapore, Singapore
[6] Agcy Sci Technol & Res, Inst Infocomm Res, Singapore, Singapore
[7] Univ Sydney, Westmead Hosp, Dept Ophthalmol, Ctr Vis Res, Sydney, NSW 2006, Australia
基金
英国医学研究理事会;
关键词
epidemiology; optic disc; optic nerve evaluation; BLUE MOUNTAINS EYE; HEIDELBERG RETINA TOMOGRAPH; SINGAPORE MALAY EYE; NERVE HEAD; COHERENCE TOMOGRAPHY; STEREO CAMERA; GLAUCOMA; AGREEMENT; PREVALENCE; POPULATION;
D O I
10.1111/ceo.12112
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo determine the reliability and agreement of a new optic disc grading software program for use in clinical, epidemiological research. DesignReliability and agreement study. Samples328 monoscopic and 85 stereoscopic optic disc images. MethodsOptic disc parameters were measured using a new optic disc grading software (Singapore Optic Disc Assessment) that is based on polynomial curve-fitting algorithm. Two graders independently graded 328 monoscopic images to determine intergrader reliability. One grader regraded the images after 1 month to determine intragrader reliability. In addition, 85 stereo optic disc images were separately selected, and vertical cup-to-disc ratios were measured using both the new software and standardized Wisconsin manual stereo-grading method by the same grader 1 month apart. Intraclass correlation coefficient (ICC) and Bland-Altman plot analyses were performed. Main Outcome MeasuresOptic disc parameters. ResultsThe intragrader and intergrader reliability for optic disc measurements using Singapore Optic Disc Assessment was high (ICC ranging from 0.82 to 0.94). The mean differences (95% limits of agreement) for intergrader vertical cup-to-disc ratio measurements were 0.00 (-0.12 to 0.13) and 0.03 (-0.15 to 0.09), respectively. The vertical cup-to-disc ratio agreement between the software and Wisconsin grading method was extremely close (ICC=0.94). The mean difference (95% limits of agreement) of vertical cup-to-disc ratio measurement between the two methods was 0.03 (-0.09 to 0.16). ConclusionsIntragrader and intergrader reliability using Singapore Optic Disc Assessment was excellent. This software was highly comparable with standardized stereo-grading method. Singapore Optic Disc Assessment is useful for grading digital optic disc images in clinical, population-based studies.
引用
收藏
页码:842 / 852
页数:11
相关论文
共 46 条
[1]  
ABRAMS LS, 1994, OPHTHALMOLOGY, V101, P1662
[2]   Agreed Statistics Measurement Method Comparison [J].
Bland, J. Martin ;
Altman, Douglas G. .
ANESTHESIOLOGY, 2012, 116 (01) :182-185
[3]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
Caprioli J, 1994, Trans Am Ophthalmol Soc, V92, P589
[6]   Prevalence of glaucoma in rural Myanmar: the Meiktila eye study [J].
Casson, J. ;
Newland, H. S. ;
Muecke, J. ;
McGovern, S. ;
Abraham, L. ;
Shein, W. K. ;
Selva, D. ;
Aung, T. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (06) :710-714
[7]   The effect of optic disc diameter on vertical cup to disc ratio percentiles in a population based cohort: the Blue Mountains Eye Study [J].
Crowston, JG ;
Hopley, CR ;
Healey, PR ;
Lee, A ;
Mitchell, P .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (06) :766-770
[8]   The ocular hypertension treatment study: Reproducibility of cup/disk ratio measurements over time at an optic disc reading center [J].
Feuer, WJ ;
Parrish, RK ;
Schiffman, JC ;
Anderson, DR ;
Budenz, DL ;
Wells, MC ;
Hess, DJ ;
Kass, MA ;
Gordon, MO .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (01) :19-28
[9]   EQUIVALENCE OF WEIGHTED KAPPA AND INTRACLASS CORRELATION COEFFICIENT AS MEASURES OF RELIABILITY [J].
FLEISS, JL ;
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1973, 33 (03) :613-619
[10]   Rationale and methodology for a population-based study of eye diseases in Malay people: The Singapore Malay eye study (SiMES) [J].
Foong, Athena W. P. ;
Saw, Seang-Mei ;
Loo, Jing-Liang ;
Shen, Sunny ;
Loon, Seng-Chee ;
Rosman, Mohamad ;
Aung, Tin ;
Tan, Donald T. H. ;
Tai, E. Shyong ;
Wong, Tien Y. .
OPHTHALMIC EPIDEMIOLOGY, 2007, 14 (01) :25-35