Performance and cutoffs for liver fibrosis staging of a two-dimensional shear wave elastography technique

被引:32
作者
Ferraioli, Giovanna [1 ,2 ]
Maiocchi, Laura [2 ]
Dellafiore, Carolina [1 ,2 ]
Tinelli, Carmine [3 ]
Above, Elisabetta [2 ]
Filice, Carlo [1 ,2 ]
机构
[1] Univ Pavia, Dipartimento Sci Clin Chirurg Diagnost & Pediat, Med Sch, Pavia, Italy
[2] Fdn IRCCS Policlin S Matteo, Clin Sci & Infect Dis Dept, Viale Camillo Golgi 19, I-27100 Pavia, Italy
[3] Fdn IRCCS Policlin S Matteo, Biometr Unit, Pavia, Italy
关键词
chronic liver disease; cirrhosis; liver fibrosis; liver steatosis; shear wave dispersion; shear wave elastography; transient elastography; viral hepatitis; viscosity; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; ACCURACY; CONSENSUS;
D O I
10.1097/MEG.0000000000001702
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives: To assess performance and cutoffs of the 2-dimensional shear wave elastography technique available on the Aplio i800 ultrasound system (Canon Medical Systems, Japan), using transient elastography as reference standard, and to assess the correlation of shear-wave-speed dispersion with liver fibrosis or steatosis. Methods: This was a single-center cross-sectional study. The correlations between values obtained with transient elastography and 2-dimensional-shear wave elastography, and between shear-wave-speed dispersion and fibrosis or steatosis, were assessed with Pearson's r. The diagnostic performance of the 2-dimensional-shear wave elastography for staging significant fibrosis and severe fibrosis compared to transient elastography was assessed using the area under the receiver operating characteristic curve analysis. Results: Three hundred sixty-seven patients (198 males and 169 females) were studied. There was a high correlation between 2-dimensional-shear wave elastography and transient elastography (r = 0.87, P < 0.0001). The area under the receiver operating characteristics of 2-dimensional-shear wave elastography for staging significant fibrosis (F2) and severe fibrosis (F3-F4), respectively, were 0.97 (95% confidence interval, 0.91-0.98) and 0.97 (95% confidence interval, 0.95-0.99). The best cutoffs for significant fibrosis and severe fibrosis, respectively, were > 7 and > 9 kPa. Shear-wave-speed dispersion showed a high correlation with fibrosis (r = 0.85, P < 0.0001), whereas there was a very weak correlation with steatosis. Conclusions: The results of this study show that this 2-dimensional-shear wave elastography technique is accurate for staging liver fibrosis. Shear-wave-speed dispersion is highly correlated with liver fibrosis but not with steatosis.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 27 条
[1]  
[Anonymous], 2015, J HEPATOL, V63, P237, DOI 10.1016/j.jhep.2015.04.006
[2]   Noninvasive Tests Accurately Identify Advanced Fibrosis due to NASH: Baseline Data From the STELLAR Trials [J].
Anstee, Quentin M. ;
Lawitz, Eric J. ;
Alkhouri, Naim ;
Wong, Vincent Wai-Sun ;
Romero-Gomez, Manuel ;
Okanoue, Takeshi ;
Trauner, Michael ;
Kersey, Kathryn ;
Li, Georgia ;
Han, Ling ;
Jia, Catherine ;
Wang, Lulu ;
Chen, Guang ;
Subramanian, G. Mani ;
Myers, Robert P. ;
Djedjos, C. Stephen ;
Kohli, Anita ;
Bzowej, Natalie ;
Younes, Ziad ;
Sarin, Shiv ;
Shiffman, Mitchell L. ;
Harrison, Stephen A. ;
Afdhal, Nezam H. ;
Goodman, Zachary ;
Younossi, Zobair M. .
HEPATOLOGY, 2019, 70 (05) :1521-1530
[3]   Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement [J].
Barr, Richard G. ;
Ferraioli, Giovanna ;
Palmeri, Mark L. ;
Goodman, Zachary D. ;
Garcia-Tsao, Guadalupe ;
Rubin, Jonathan ;
Garra, Brian ;
Myers, Robert P. ;
Wilson, Stephanie R. ;
Rubens, Deborah ;
Levine, Deborah .
RADIOLOGY, 2015, 276 (03) :845-861
[4]   SHEAR WAVE DISPERSION MEASURES LIVER STEATOSIS [J].
Barry, Christopher T. ;
Mills, Bradley ;
Hah, Zaegyoo ;
Mooney, Robert A. ;
Ryan, Charlotte K. ;
Rubens, Deborah J. ;
Parker, Kevin J. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (02) :175-182
[5]   Performance of 2D-SWE.GE for predicting different stages of liver fibrosis, using Transient Elastography as the reference method [J].
Bende, Felix ;
IoanSporea ;
Sirli, Roxana ;
Popescu, Alina ;
Mare, Ruxandra ;
Miutescu, Bogdan ;
Lupusoru, Raluca ;
Moga, Tudor ;
Pienar, Corina .
MEDICAL ULTRASONOGRAPHY, 2017, 19 (02) :143-149
[6]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[7]   Assessment of Liver Viscoelasticity by Using Shear Waves Induced by Ultrasound Radiation Force [J].
Chen, Shigao ;
Sanchez, William ;
Callstrom, Matthew R. ;
Gorman, Brian ;
Lewis, Jason T. ;
Sanderson, Schuyler O. ;
Greenleaf, James F. ;
Xie, Hua ;
Shi, Yan ;
Pashley, Michael ;
Shamdasani, Vijay ;
Lachman, Michael ;
Metz, Stephen .
RADIOLOGY, 2013, 266 (03) :964-970
[9]   Investigating liver stiffness and viscosity for fibrosis, steatosis and activity staging using shear wave elastography [J].
Deffieux, Thomas ;
Gennisson, Jean-Luc ;
Bousquet, Laurence ;
Corouge, Marion ;
Cosconea, Simona ;
Amroun, Dalila ;
Tripon, Simona ;
Terris, Benoit ;
Mallet, Vincent ;
Sogni, Philippe ;
Tanter, Mickael ;
Pol, Stanislas .
JOURNAL OF HEPATOLOGY, 2015, 62 (02) :317-324
[10]  
Dietrich CF, 2017, ULTRASCHALL MED, V38, pE52, DOI [10.1055/a-0641-0076, 10.1055/s-0043-103952]