Inorganic scintillator detectors for real-time verification during brachytherapy

被引:11
作者
Kertzscher, G. [1 ]
Beddar, S. [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci Houston, Houston, TX 77030 USA
来源
9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY | 2017年 / 847卷
关键词
DOSIMETRY;
D O I
10.1088/1742-6596/847/1/012036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Widespread use of real-time dose measurement technology to verify brachytherapy (BT) treatments is currently limited because only few detectors exhibit the large dynamic range and signal intensities that is required to accurately report the data. Inorganic scintillator detectors (ISDs) are promising for real-time BT verification because they can exhibit large signal intensities. Luminescence properties of ISDs based on ruby, Y2O3:Eu and CsI:Tl were compared with BCF-60 plastic scintillators to determine their potential for BT verification. Measurements revealed that ISDs can exhibit signal intensities 1800 times larger than BCF-60 and that the Cerenkov and fluorescence light contamination is negligible. The favourable luminescence properties of ISDs opens the possibility to manufacture simplified detector systems that can lead to more widespread real-time verification during BT treatment deliveries.
引用
收藏
页数:4
相关论文
共 50 条
[21]   URETHRA-SPARING, INTRAOPERATIVE, REAL-TIME PLANNED, PERMANENT-SEED PROSTATE BRACHYTHERAPY: TOXICITY ANALYSIS [J].
Zilli, Thomas ;
Taussky, Daniel ;
Donath, David ;
Hoa Phong Le ;
Larouche, Renee-Xaviere ;
Beliveau-Nadeau, Dominique ;
Hervieux, Yannick ;
Delouya, Guila .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (04) :E377-E383
[22]   Intraoperative real-time planned conformal prostate brachytherapy: Post-implantation dosimetric outcome and clinical implications [J].
Zelefsky, Michael J. ;
Yamada, Yoshiya ;
Cohen, Gil'ad N. ;
Sharma, Neha ;
Shippy, Alison M. ;
Fridman, David ;
Zaider, Marco .
RADIOTHERAPY AND ONCOLOGY, 2007, 84 (02) :185-189
[23]   Verification of the performance accuracy of a real-time skin-dose tracking system for interventional fluoroscopic procedures [J].
Bednarek, Daniel R. ;
Barbarits, Jeffery ;
Rana, Vijay K. ;
Nagaraja, Srikanta P. ;
Josan, Madhur S. ;
Rudin, Stephen .
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
[24]   SPATIOTEMPORAL DISTRIBUTION OF NANODROPLET VAPORIZATION IN A PROTON BEAM USING REAL-TIME ULTRASOUND IMAGING FOR RANGE VERIFICATION [J].
Collado-Lara, Gonzalo ;
Heymans, Sophie, V ;
Rovituso, Marta ;
Carlier, Bram ;
Toumia, Yosra ;
Verweij, Martin ;
Paradossi, Gaio ;
Sterpin, Edmond ;
Vos, Hendrik J. ;
D'hooge, Jan ;
de Jong, Nico ;
Van den Abeele, Koen ;
Daeichin, Verya .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (01) :149-156
[25]   First results on real-time imaging and dosimetry of β emitting sources for medical applications using silicon strip detectors [J].
Cappellini, C ;
Bulgheroni, A ;
Bianchi, C ;
Caccia, M ;
Grigoriev, E ;
Kucewicz, W ;
Mozzanica, A ;
Prest, M ;
Rovere, M ;
Sampietro, C ;
Vallazza, E .
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, :2293-2295
[26]   In vivo measurement of radiation dose during brachytherapy treatment using scintillation detectors [J].
Sobiech, Bogna ;
Winiecki, Janusz ;
Witkiewicz-Lukaszek, Sandra ;
Zorenko, Yuriy ;
Makarewicz, Roman ;
Wrobel, Patrycja .
POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2024, 30 (04)
[27]   Advantages of real-time transabdominal ultrasound guidance in combined interstitial/intracavitary cervical brachytherapy: a case-based review [J].
Thibodeau, Ryan ;
Simone, Brittany A. ;
Tanny, Sean ;
Hahn, Seung Shin ;
Aridgides, Paul D. .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2021, 13 (02) :211-220
[28]   A wearable tool for real-time dose monitoring during cancer radiation therapies [J].
Fratelli, Ilaria ;
Carturan, Sara M. ;
Tommasino, Francesco ;
Basirico, Laura ;
Pino, Felix ;
Valletta, Antonio ;
Campajola, Marcello ;
Rapisarda, Matteo ;
Calvi, Sabrina ;
Scagliotti, Mattia ;
Ciavatti, Andrea ;
Tortora, Luca ;
Verroi, Enrico ;
Delgado, Jessica C. ;
Margotti, Lorenzo ;
Bordoni, Camilla ;
Napolitano, Giulia ;
Moretto, Sandra ;
Aloisio, Alberto ;
Sarnelli, Ettore ;
Branchini, Paolo ;
Mariucci, Luigi ;
Quaranta, Alberto ;
Fraboni, Beatrice .
SCIENCE ADVANCES, 2025, 11 (17)
[29]   Real-time in vivo Cherenkoscopy imaging during external beam radiation therapy [J].
Zhang, Rongxiao ;
Gladstone, David J. ;
Jarvis, Lesley A. ;
Strawbridge, Rendall R. ;
Hoopes, P. Jack ;
Friedman, Oscar D. ;
Glaser, Adam K. ;
Pogue, Brian W. .
JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (11)
[30]   Real-time intraoperative evaluation of implant quality and dose correction during prostate brachytherapy consistently improves target coverage using a novel image fusion and optimization program [J].
Zelefsky, Michael J. ;
Cohen, Gilad N. ;
Taggar, Amandeep S. ;
Kollmeier, Marisa ;
McBride, Sean ;
Mageras, Gig ;
Zaider, Marco .
PRACTICAL RADIATION ONCOLOGY, 2017, 7 (05) :319-324