Inorganic scintillator detectors for real-time verification during brachytherapy

被引:11
|
作者
Kertzscher, G. [1 ]
Beddar, S. [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci Houston, Houston, TX 77030 USA
来源
9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY | 2017年 / 847卷
关键词
DOSIMETRY;
D O I
10.1088/1742-6596/847/1/012036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Widespread use of real-time dose measurement technology to verify brachytherapy (BT) treatments is currently limited because only few detectors exhibit the large dynamic range and signal intensities that is required to accurately report the data. Inorganic scintillator detectors (ISDs) are promising for real-time BT verification because they can exhibit large signal intensities. Luminescence properties of ISDs based on ruby, Y2O3:Eu and CsI:Tl were compared with BCF-60 plastic scintillators to determine their potential for BT verification. Measurements revealed that ISDs can exhibit signal intensities 1800 times larger than BCF-60 and that the Cerenkov and fluorescence light contamination is negligible. The favourable luminescence properties of ISDs opens the possibility to manufacture simplified detector systems that can lead to more widespread real-time verification during BT treatment deliveries.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Online treatment verification during brachytherapy using an inorganic scintillator - a phantom study
    Johansen, J.
    Jorgensen, E. B.
    Georgi, P.
    Tanderup, K.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S90 - S91
  • [2] THE REAL-TIME VERIFICATION
    PELTOLA, S
    MEDICAL PHYSICS, 1988, 15 (05) : 799 - 799
  • [3] In vivo real-time dosimetric verification in high dose rate prostate brachytherapy
    Seymour, Erin L.
    Downes, Simon J.
    Fogarty, Gerald B.
    Izard, Michael A.
    Metcalfe, Peter
    MEDICAL PHYSICS, 2011, 38 (08) : 4785 - 4794
  • [4] Real-time verification of HDR brachytherapy source location: implementation of detector redundancy
    Nakano, T
    Suchowerska, N
    McKenzie, DR
    Bilek, MM
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (02): : 319 - 327
  • [5] Red-emitting inorganic scintillation detectors to verify HDR brachytherapy treatments in real time
    Kertzscher, G.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S144 - S144
  • [6] A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy
    Therriault-Proulx, Francois
    Briere, Tina M.
    Mourtada, Firas
    Aubin, Sylviane
    Beddar, Sam
    Beaulieu, Luc
    MEDICAL PHYSICS, 2011, 38 (05) : 2542 - 2551
  • [7] An innovative gynecological HDR brachytherapy applicator system for treatment delivery and real-time verification
    Romanyukha, Anna
    Carrara, Mauro
    Mazzeo, Davide
    Tenconi, Chiara
    Al-Salmani, Tebarak
    Poder, Joel
    Cutajar, Dean
    Fuduli, Iolanda
    Petasecca, Marco
    Bucci, Joseph
    Cerrotta, Annamaria
    Pappalardi, Brigida
    Piccolo, Federica
    Pignoli, Emanuele
    Rosenfeld, Anatoly
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 151 - 157
  • [8] ORGANIC SCINTILLATOR FOR REAL-TIME NEUTRON DOSIMETRY
    Beyer, Kyle A.
    Di Fulvio, Angela
    Stolarczyk, Liliana
    Parol, Wiktor
    Mojzeszek, Natalia
    Kopec, Renata
    Clarke, Shaun D.
    Pozzi, Sara A.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 355 - 359
  • [9] Adaptive and Real-time Approaches in Brachytherapy
    Hellebust, T. P.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S289 - S289
  • [10] Real-time dosimetry for HDR brachytherapy
    Moutinho, L.
    Castro, I. F. C.
    Freitas, H.
    Silva, K. A.
    Rachinhas, P. J.
    Simoes, P. C. P. S.
    Veloso, J. F. C. A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S945 - S945