Clinical Experience of Combined HeartWare Ventricular Assist Device and Implantable Cardioverter Defibrillator Therapy

被引:8
作者
Pecha, Simon [1 ]
Wilke, Iris [2 ]
Bernhardt, Alexander [1 ]
Hakmi, Samer [1 ]
Yildirim, Yalin [1 ]
Steven, Daniel [2 ]
Reichenspurner, Hermann [1 ]
Willems, Stephan [2 ]
Deuse, Tobias [1 ]
Aydin, Ali [2 ]
机构
[1] Univ Heart Ctr, Dept Cardiovasc Surg, Hamburg, Germany
[2] Univ Heart Ctr, Dept Electrophysiol, Hamburg, Germany
关键词
implantable cardioverter defibrillator; left ventricular assist device; ventricular arrhythmias; ventricular tachycardia; INTERMACS ANNUAL-REPORT; TASK-FORCE; FAILURE; ARRHYTHMIAS; SURVIVAL; SUPPORT; COLLABORATION; GUIDELINES;
D O I
10.1111/jce.12455
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
HeartWare Ventricular Assist Device and Implantable Cardioverter Defibrillator IntroductionThe HeartWare continuous flow ventricular assist device (HVAD) is used in an increasing number of heart failure patients. In those patients, ventricular arrhythmias (VAs) are common and, consequently, many patients already have an implanted implantable cardioverter defibrillator (ICD) in place or receive ICD implantation after left ventricular assist device implantation. However, limited data on feasibility and necessity of combined ICD and HVAD therapy are available. In this study we present our technical and clinical experience. Methods and ResultsBetween 01/2010 and 06/2013, 41 patients received HVAD implantation. Twenty-six HVAD patients who already had an ICD device placed prior to HVAD implantation or received ICD implantation afterwards were enrolled in this study. Peri- and postoperative complications as well as ICD interrogations were documented and analyzed retrospectively. Mean patients age was 58.4 12.6 years; 88.5% of patients were male. During mean follow-up of 12.2 +/- 8.9 months, appropriate ICD interventions occurred in 9 patients (34.6%) due to ventricular tachyarrhythmia (n = 7) or ventricular fibrillation (n = 2). An inappropriate ICD intervention was seen in 1 patient (3.9%) due to tachycardic atrial fibrillation. Patients on HVAD with a history of VAs (n = 13) had a significantly higher incidence of ICD interventions compared to patients with primary prophylactic indication for ICD (n = 13; 53.8% vs. 7.7%; P = 0.015). No disturbance of ICD function was seen after HVAD implantation. ConclusionCombined ICD and HVAD therapy was safe and feasible, without electromagnetic interference between ICD and ventricular assist device. The incidence of ICD interventions was high in patients with a history of VAs, but low in patients with ICD implantation for primary prevention.
引用
收藏
页码:1109 / 1114
页数:6
相关论文
共 29 条
[1]   Implantable cardioverter-defibrillator shocks in patients with a left ventricular assist device [J].
Ambardekar, Amrut V. ;
Allen, Larry A. ;
Lindenfeld, JoAnn ;
Lowery, Christopher M. ;
Cannon, Anne P. ;
Cleveland, Joseph C., Jr. ;
Brieke, Andreas ;
Sauer, William H. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (07) :771-776
[2]   Incidence of Ventricular Arrhythmias in Patients on Long-term Support With a Continuous-flow Assist Device (HeartMate II) [J].
Andersen, Mads ;
Videbaek, Regitze ;
Boesgaard, Soren ;
Sander, Kare ;
Hartsen, Peter B. ;
Gustafsson, Finn .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (07) :733-735
[3]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[4]   Ventricular Fibrillation in an Ambulatory Patient Supported by a Left Ventricular Assist Device: Highlighting the ICD Controversy [J].
Boilson, Barry A. ;
Durham, Lucian A. ;
Park, Soon J. .
ASAIO JOURNAL, 2012, 58 (02) :170-173
[5]   Improved survival among ventricular assist device recipients with a concomitant implantable cardioverter-defibrillator [J].
Cantillon, Daniel J. ;
Tarakji, Khaldoun G. ;
Kumbhani, Dharam J. ;
Smedira, Nicholas G. ;
Starling, Randall C. ;
Wilkoff, Bruce L. .
HEART RHYTHM, 2010, 7 (04) :466-471
[6]   The Role of Implantable Cardioverter-Defibrillators in Patients With Continuous Flow Left Ventricular Assist Devices [J].
Enriquez, Alan D. ;
Calenda, Brandon ;
Miller, Marc A. ;
Anyanwu, Anelechi C. ;
Pinney, Sean P. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (04) :668-674
[7]   ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons [J].
Epstein, Andrew E. ;
DiMarco, John P. ;
Ellenbogen, Kenneth A. ;
Estes, N. A. Mark, III ;
Freedman, Roger A. ;
Gettes, Leonard S. ;
Gillinov, A. Marc ;
Gregoratos, Gabriel ;
Hammill, Stephen C. ;
Hayes, David L. ;
Hlatky, Mark A. ;
Newby, L. Kristin ;
Page, Richard L. ;
Schoenfeld, Mark H. ;
Silka, Michael J. ;
Stevenson, Lynne Warner ;
Sweeney, Michael O. .
CIRCULATION, 2008, 117 (21) :E350-E408
[8]   Left Ventricular Mechanical Assist Devices and Cardiac Device Interactions: An Observational Case Series [J].
Foo, David ;
Walker, Bruce D. ;
Kuchar, Dennis L. ;
Thorburn, Charles W. ;
Tay, Andre ;
Hayward, Christopher S. ;
Macdonald, Peter ;
Keogh, Anne ;
Kotlyar, Eugene ;
Spratt, Philip ;
Jansz, Paul .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (07) :879-887
[9]   Ventricular Arrhythmias and Implantable Cardioverter-Defibrillator Therapy in Patients With Continuous-Flow Left Ventricular Assist Devices Need for Primary Prevention? [J].
Garan, Arthur R. ;
Yuzefpolskaya, Melana ;
Colombo, Paolo C. ;
Morrow, John P. ;
Te-Frey, Rosie ;
Dano, Drew ;
Takayama, Hiroo ;
Naka, Yoshifumi ;
Garan, Hasan ;
Jorde, Ulrich P. ;
Uriel, Nir .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (25) :2542-2550
[10]   Effect of acute unloading via head-up tilt on QTc prolongation in patients with ischemic or non-ischemic cardiomyopathy [J].
Grzywacz, FW ;
Piacentino, V ;
Marble, J ;
Bozorgnia, B ;
Gaughan, JP ;
Rothman, SA ;
Margulies, KB .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (03) :412-415