Inactivation of natural enteric bacteria in real municipal wastewater by solar photo-Fenton at neutral pH

被引:57
作者
Ortega-Gomez, E. [1 ,2 ]
Esteban Garcia, B. [1 ,2 ]
Ballesteros Martin, M. M. [2 ,3 ]
Fernandez Ibanez, P. [2 ,4 ]
Sanchez Perez, J. A. [1 ,2 ]
机构
[1] Univ Almeria, Dept Chem Engn, Almeria 04120, Spain
[2] Univ Almeria, CIEMAT, CIESOL, Joint Ctr, Almeria 04120, Spain
[3] Univ Pablo Olavide, Dept Mol Biol & Biochem Engn, Seville 41013, Spain
[4] CIEMAT, Plataforma Solar Almeria, Tabernas 04200, Almeria, Spain
关键词
Solar disinfection; Photo-Fenton; Neutral pH; Escherichia coli; Total coliform; Reclaimed water; ADVANCED OXIDATION PROCESSES; HYDROGEN-PEROXIDE; TREATMENT-PLANT; DISINFECTION SODIS; ESCHERICHIA-COLI; PET BOTTLES; WELL WATER; H2O2; DEGRADATION; EFFLUENTS;
D O I
10.1016/j.watres.2014.05.034
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study analyses the use of the solar photo-Fenton treatment in compound parabolic collector photo-reactors at neutral pH for the inactivation of wild enteric Escherichia coli and total coliform present in secondary effluents of a municipal wastewater treatment plant (SEWWTP). Control experiments were carried out to find out the individual effects of mechanical stress, pH, reactants concentration, and UVA radiation as well as the combined effects of UVA-Fe and UVA-H2O2. The synergistic germicidal effect of solar-UVA with 50 mg L-1 of H2O2 led to complete disinfection (up to the detection limit) of total coliforms within 120 mm. The disinfection process was accelerated by photo-Fenton, achieving total inactivation in 60 min reducing natural bicarbonate concentration found in the SEWWTP from 250 to 100 mg L-1 did not give rise to a significant enhancement in bacterial inactivation. Additionally, the effect of hydrogen peroxide and iron dosage was evaluated. The best conditions were 50 mg L-1 of H2O2 and 20 mg L-1 of Fe2+. Due to the variability of the SEWWTP during autumn and winter seasons, the inactivation kinetic constant varied between 0.07 +/- 0.04 and 0.17 +/- 0.04 min(-1). Moreover, the water treated by solar photo-Fenton fulfilled the microbiological quality requirement for wastewater reuse in irrigation as per the WHO guidelines and in particular for Spanish legislation. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:316 / 324
页数:9
相关论文
共 34 条
[1]   Solar Advanced Oxidation Processes as disinfection tertiary treatments for real wastewater: Implications for water reclamation [J].
Agullo-Barcelo, M. ;
Polo-Lopez, M. I. ;
Lucena, F. ;
Jofre, J. ;
Fernandez-Ibanez, P. .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2013, 136 :341-350
[2]  
[Anonymous], 2004, Water Treatment and Pathogen Control: Process Efficiency in Achieving Safe Drinking Water
[3]   Solar photocatalysis as a tertiary treatment to remove emerging pollutants from wastewater treatment plant effluents [J].
Bernabeu, A. ;
Vercher, R. F. ;
Santos-Juanes, L. ;
Simon, P. J. ;
Lardin, C. ;
Martinez, M. A. ;
Vicente, J. A. ;
Gonzalez, R. ;
Llosa, C. ;
Arques, A. ;
Amat, A. M. .
CATALYSIS TODAY, 2011, 161 (01) :235-240
[4]   Iron dosage as a strategy to operate the photo-Fenton process at initial neutral pH [J].
Carra, I. ;
Casas Lopez, J. L. ;
Santos-Juanes, L. ;
Malato, S. ;
Sanchez Perez, J. A. .
CHEMICAL ENGINEERING JOURNAL, 2013, 224 :67-74
[5]   Inactivation of Escherichia coli by photochemical reaction of ferrioxalate at slightly acidic and near-neutral pHs [J].
Cho, M ;
Lee, Y ;
Chung, H ;
Yoon, J .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (02) :1129-1134
[6]  
FAO, 2012, STAT YB, P55
[7]   Synergic antibacterial effect between visible light and hydrogen peroxide on Streptococcus mutans [J].
Feuerstein, O ;
Moreinos, D ;
Steinberg, D .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2006, 57 (05) :872-876
[8]   Cellular defenses against superoxide and hydrogen peroxide [J].
Imlay, James A. .
ANNUAL REVIEW OF BIOCHEMISTRY, 2008, 77 :755-776
[9]   Mild solar photo-Fenton: An effective tool for the removal of Fusarium from simulated municipal effluents [J].
Inmaculada Polo-Lopez, M. ;
Garcia-Fernandez, Irene ;
Velegraki, Theodora ;
Katsoni, Athanasia ;
Oller, Isabel ;
Mantzavinos, Dionissios ;
Fernandez-Ibanez, Pilar .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2012, 111 :545-554
[10]   Degradation of emerging contaminants at low concentrations in MWTPs effluents with mild solar photo-Fenton and TiO2 [J].
Klamerth, N. ;
Miranda, N. ;
Malato, S. ;
Agueera, A. ;
Fernandez-Alba, A. R. ;
Maldonado, M. I. ;
Coronado, J. M. .
CATALYSIS TODAY, 2009, 144 (1-2) :124-130