Simulation, design, and test of an elliptical surface coil for magnetic resonance imaging and spectroscopy

被引:7
作者
Giovannetti, Giulio [1 ,2 ]
Flori, Alessandra [2 ]
De Marchi, Daniele [2 ,3 ]
Matarazzo, Giuseppe
Frijia, Francesca [2 ]
Burchielli, Silvia [2 ]
Montanaro, Domenico [2 ]
Aquaro, Giovanni Donato [2 ]
Menichetti, Luca [1 ,2 ]
机构
[1] CNR, Natl Res Council, Inst Clin Physiol, Pisa, Italy
[2] Fdn CNR Reg Toscana G Monasterio, Pisa, Italy
[3] AITIRM, Florence, Italy
关键词
coil simulation; inductance; magnetic field; resistance; signal-to-noise ratio; TO-NOISE RATIO; RADIOFREQUENCY COIL;
D O I
10.1002/cmr.b.21361
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The simplest design of surface coils for magnetic resonance imaging (MRI) applications is circular and square loops, both producing a magnetic field perpendicular to the coil plane in the central region-of-interest (ROI), with an amplitude that decreases along the coil axis. However, a surface coil constituted by a loop with different geometry could be necessary when particular field-of-views (FOVs) are desired, especially for performing imaging in an elongated region. This can be achieved by using an elliptical loop, which can guarantee a wide longitudinal FOV and a good penetration in deep sample regions. This work proposes the application of a method for elliptical coil Signal-to-Noise Ratio (SNR) estimation previously developed for circular and square loop design, in which coil inductance and resistance are analytically calculated and the magnetic field pattern is estimated using the magnetostatic approach, while the sample-induced resistance is calculated with the vector potential calculation method. In the second part of the paper, we propose the simulation and the design of a transmit/receive elliptical coil for MRI in mice with a 3T clinical scanner. We also evaluated the coil performance in a preliminary magnetic resonance spectroscopy (MRS) study in phantom.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Concentric dual-loop RF coil for magnetic resonance imaging
    Hernández, R
    Rodríguez, A
    Salgado, P
    Barrios, FA
    REVISTA MEXICANA DE FISICA, 2003, 49 (02) : 107 - 114
  • [22] Single-loop coil concepts for intravascular magnetic resonance imaging
    Quick, HH
    Ladd, ME
    Zimmermann-Paul, GG
    Erhart, P
    Hofmann, E
    von Schulthess, GK
    Debatin, JF
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (04) : 751 - 758
  • [23] Perspectives in Wireless Radio Frequency Coil Development for Magnetic Resonance Imaging
    Nohava, Lena
    Ginefri, Jean-Christophe
    Willoquet, Georges
    Laistler, Elmar
    Frass-Kriegl, Roberta
    FRONTIERS IN PHYSICS, 2020, 8
  • [24] Silicon Cylinder Spiral Coil for Nuclear Magnetic Resonance Spectroscopy of Nanoliter Samples
    Leidich, Stefan
    Braun, Marco
    Gessner, Thomas
    Riemer, Thomas
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2009, 35B (01) : 11 - 22
  • [25] Automatic Resonance Frequency Retuning of Stretchable Liquid Metal Receive Coil for Magnetic Resonance Imaging
    Mehmann, Andreas
    Vogt, Christian
    Varga, Matija
    Port, Andreas
    Reber, Jonas
    Marjanovic, Josip
    Pruessmann, Klaas Paul
    Sporrer, Benjamin
    Huang, Qiuting
    Troster, Gerhard
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) : 1420 - 1426
  • [26] Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging
    Seo, Jeung-Hoon
    Ryu, Yeunchul
    Chung, Jun-Young
    SENSORS, 2022, 22 (11)
  • [27] Radiofrequency magnetic resonance coils and communication antennas: Simulation and design strategies
    Giovannetti, Giulio
    Tiberi, Gianluigi
    MAGNETIC RESONANCE IMAGING, 2017, 44 : 1 - 7
  • [28] Design and optimization of the magnetic circuit of a mobile nuclear magnetic resonance device for magnetic resonance imaging
    Popella, H
    Henneberger, G
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2001, 20 (01) : 269 - 278
  • [29] Magnetic Resonance Imaging of Osteochondral Lesions of the Talus: Comparison Between Small FOV Surface Coil with BLADE and Boot-Shape Coil Without BLADE
    Sun, Yan
    Hao, Yue Feng
    Hu, Dan
    Liu, Ke Fu
    IRANIAN JOURNAL OF RADIOLOGY, 2019, 16 (04)
  • [30] Magnetic Resonance Imaging Receiver Coil Decoupling Using Circumferential Shielding Structures
    Yeh, Jhy-Neng Tasso
    Lin, Fa-Hsuan
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 6254 - 6257