Demonstration of high-precision continuous measurements of water vapor isotopologues in laboratory and remote field deployments using wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) technology

被引:232
作者
Gupta, Priya [1 ]
Noone, David [2 ,3 ]
Galewsky, Joseph [4 ]
Sweeney, Colm [3 ,5 ]
Vaughn, Bruce H. [6 ]
机构
[1] Picarro Inc, Sunnyvale, CA 94085 USA
[2] Univ Colorado, Dept Atmospher & Ocean Sci, Boulder, CO 80309 USA
[3] Univ Colorado, Cooperat Inst Res Environm Sci, Boulder, CO 80309 USA
[4] Univ New Mexico, Dept Earth & Planetary Sci, Albuquerque, NM 87131 USA
[5] NOAA, Earth Syst Res Lab, Boulder, CO 80304 USA
[6] Univ Colorado, Inst Arctic & Alpine Res, Boulder, CO 80309 USA
关键词
PRECIPITATION; DEUTERIUM; O-18;
D O I
10.1002/rcm.4100
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study demonstrates the application of Wavelength-Scanned Cavity Ring-Down Spectroscopy (WS-CRDS) technology which is used to measure the stable isotopic composition of water. This isotopic water analyzer incorporates an evaporator system that allows liquid water as well as water vapor to be measured with high precision. The analyzer can measure (H2O)-O-18, (H2O)-O-16 and (HDO)-O-16 content of the water sample simultaneously. The results of a laboratory test and two field trials with this analyzer are described. The results of these trials show that the isotopic water analyzer gives precise, accurate measurements with little or no instrument drift for the two most common isotopologues of water. In the laboratory the analyzer has a precision of 0.5 per mil for delta D and 0.1 per mil for delta O-18 which is similar to the precision obtained by laboratory-based isotope ratio mass spectrometers. In the field, when measuring vapor samples, the analyzer has a precision of 1.0 per mil for delta D and 0.2 per mil for delta O-18. These results demonstrate that the isotopic water analyzer is a powerful tool that is appropriate for use in a wide range of applications and environments. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:2534 / 2542
页数:9
相关论文
共 23 条
[21]   An automated system for hydrogen isotope analysis of water [J].
Vaughn, BH ;
White, JWC ;
Delmotte, M ;
Trolier, M ;
Cattani, O ;
Stievenard, M .
CHEMICAL GEOLOGY, 1998, 152 (3-4) :309-319
[22]   High Resolution Pore Water δ2H and δ18O Measurements by H2O(liquid)-H2O(vapor) Equilibration Laser Spectroscopy [J].
Wassenaar, L. I. ;
Hendry, M. J. ;
Chostner, V. L. ;
Lis, G. P. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (24) :9262-9267
[23]   Timing is everything in a game of two hemispheres [J].
White, JWC ;
Steig, EJ .
NATURE, 1998, 394 (6695) :717-718