We prospectively analyzed three types of ureteral stents to determine the effects of diameter and composition on a patient's symptoms, Twenty stents were placed consecutively in each of the three study groups for the treatment of ureteral obstruction, prior to SWL, or following ureteroscopy: Group I = 6F PercuflexTM stent, Group II = 6F HydroPlusTM stent, and Group III = 4.8F HydroPlusTM stent. All stents were removed in clinic 7 to 10 days after placement, At this time, a confidential questionnaire was completed by the patient addressing the symptoms associated with the indwelling catheter, The 6F hydrogel-coated stents were somewhat easier to insert, especially in high-grade obstructions, Occasional difficulty in seeing the 4.8F stent during fluoroscopy was noted, No statistically significant difference in any of the irritative voiding symptoms-dysuria (P = 0.7998), urgency (P = 0.0928), frequency (P = 0.2646), nocturia (P = 0.2855), hematuria (P = 0.9417), pain (P = 0.4524), or incontinence (P = 0.4524)-was demonstrated, Differences in stent diameter and composition do not appear to affect symptoms, We prefer the hydrogel-coated 6F stent, as it offers advantages in ease of placement and radiographic visibility without increased symptoms.
引用
收藏
页码:45 / 47
页数:3
相关论文
共 8 条
[1]   MORBIDITY ASSOCIATED WITH INDWELLING INTERNAL URETERAL STENTS AFTER SHOCK-WAVE LITHOTRIPSY [J].
BREGG, K ;
RIEHLE, RA .
JOURNAL OF UROLOGY, 1989, 141 (03) :510-512
[2]   BIOCOMPATIBILITY OF VARIOUS INDWELLING DOUBLE-J STENTS [J].
CORMIO, L ;
TALJA, M ;
KOIVUSALO, A ;
MAKISALO, H ;
WOLFF, H ;
RUUTU, M .
JOURNAL OF UROLOGY, 1995, 153 (02) :494-496
[3]   POLYURETHANE INTERNAL URETERAL STENTS IN TREATMENT OF STONE PATIENTS - MORBIDITY RELATED TO INDWELLING TIMES [J].
ELFAQIH, SR ;
SHAMSUDDIN, AB ;
CHAKRABARTI, A ;
ATASSI, R ;
KARDAR, AH ;
OSMAN, MK ;
HUSAIN, I .
JOURNAL OF UROLOGY, 1991, 146 (06) :1487-1491
[4]  
LINGEMAN JE, 1995, J ENDOUROL S, V9, pS10
[5]   COMPARATIVE-EVALUATION OF MATERIALS USED FOR INTERNAL URETERAL STENTS [J].
MARDIS, HK ;
KROEGER, RM ;
MORTON, JJ ;
DONOVAN, JM .
JOURNAL OF ENDOUROLOGY, 1993, 7 (02) :105-115
[6]   COMPARISON OF SYMPTOM CHARACTERISTICS OF INDWELLING URETERAL CATHETERS [J].
PRYOR, JL ;
LANGLEY, MJ ;
JENKINS, AD .
JOURNAL OF UROLOGY, 1991, 145 (04) :719-722
[7]   INDWELLING URETERAL STENTS - IMPACT OF MATERIAL AND SHAPE ON PATIENT COMFORT [J].
THOMAS, R .
JOURNAL OF ENDOUROLOGY, 1993, 7 (02) :137-140
[8]  
THORNHILL JA, 1995, CONTROVERSIES ENDOUR, P287