Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill

被引:297
作者
Reinhart, K
Kuhn, HJ
Hartog, C
Bredle, DL
机构
[1] Univ Jena, Dept Anesthesia & Intens Care Med, D-07747 Jena, Germany
[2] Univ Wisconsin, Dept Kinesiol, Eau Claire, WI 54701 USA
关键词
central venous oxygen saturation; mixed venous oxygen saturation; fiberoptic; oximetry;
D O I
10.1007/s00134-004-2337-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To compare the course of continuously measured mixed and central venous O-2 saturations in high-risk patients and to evaluate the impact of various factors that might interfere with reflection spectrophotometry. Design and setting. Prospective, descriptive study in the interdisciplinary ICU of a university hospital. Patients. 32 critically ill patients with triple-lumen central vein catheters, including 29 patients requiring pulmonary artery catheterization. Interventions. The accuracy of fiberoptic measurements was assessed by comparison to reference co-oximeter results at regular intervals. We examined the effect on measurement accuracy of physiological variables including hematocrit, hemoglobin, pH, temperature, and the administration of various solutions via central venous catheter. Continuous parallel measurements of SvO(2) and ScvO(2) were performed in patients with each type of catheters over a total observation time of 1097 h. Results. ScvO(2) values were more accurate and stable than in vitro oximeter measurements (r=0.96 from 150 samples, mean difference 0.15%, average drift 0.10%/day) and was not significantly affected by synchronous infusion therapy or by changes in hematocrit, hemoglobin, pH, or temperature. ScvO(2) values closely paralleled SvO(2), whether measured in vitro (r=0.88 from 150 samples) or in vivo (r=0.81 from 395,128 samples) but averaged about 7+/-4 saturation percentage higher. ScvO(2) changed in parallel in 90% of the 1,498 instances in which SvO(2) changed more than 5% (over an average of 43 min). Conclusions. Continuous fiberoptic measurement of central vein O-2 saturation has potential to be a reliable and convenient tool which could rapidly warn of acute change in the oxygen supply/demand ratio of critically ill patients.
引用
收藏
页码:1572 / 1578
页数:7
相关论文
共 36 条
  • [21] Resuscitation of the critically ill in the ED: Responses of blood pressure, heart rate, shock index, central venous oxygen saturation, and lactate
    Rady, MY
    Rivers, EP
    Nowak, RM
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1996, 14 (02) : 218 - 225
  • [22] PA catheterization - quo vadis? Do we have to change the current practice with this monitoring device?
    Reinhart, K
    Radermacher, P
    Sprung, CL
    Phelan, D
    Bakker, J
    Steltzer, H
    [J]. INTENSIVE CARE MEDICINE, 1997, 23 (06) : 605 - 609
  • [23] ACCURACY OF 2 MIXED VENOUS SATURATION CATHETERS DURING LONG-TERM USE IN CRITICALLY ILL PATIENTS
    REINHART, K
    MOSER, N
    RUDOLPH, T
    BREDLE, D
    SPECHT, M
    GRAMM, HJ
    GOECKE, J
    EYRICH, K
    [J]. ANESTHESIOLOGY, 1988, 69 (05) : 769 - 773
  • [24] COMPARISON OF CENTRAL-VENOUS TO MIXED-VENOUS OXYGEN-SATURATION DURING CHANGES IN OXYGEN-SUPPLY DEMAND
    REINHART, K
    RUDOLPH, T
    BREDLE, DL
    HANNEMANN, L
    CAIN, SM
    [J]. CHEST, 1989, 95 (06) : 1216 - 1221
  • [25] Early goal-directed therapy in the treatment of severe sepsis and septic shock.
    Rivers, E
    Nguyen, B
    Havstad, S
    Ressler, J
    Muzzin, A
    Knoblich, B
    Peterson, E
    Tomlanovich, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (19) : 1368 - 1377
  • [26] Rivers E P, 2001, Curr Opin Crit Care, V7, P204, DOI 10.1097/00075198-200106000-00011
  • [28] CRITICAL ASSESSMENT OF USE OF CENTRAL VENOUS OXYGEN SATURATION AS A MIRROR OF MIXED VENOUS OXYGEN IN SEVERELY ILL CARDIAC PATIENTS
    SCHEINMAN, MM
    BROWN, MA
    RAPAPORT, E
    [J]. CIRCULATION, 1969, 40 (02) : 165 - +
  • [29] CAN CENTRAL VENOUS-BLOOD REPLACE MIXED VENOUS-BLOOD SAMPLES
    TAHVANAINEN, J
    MERETOJA, O
    NIKKI, P
    [J]. CRITICAL CARE MEDICINE, 1982, 10 (11) : 758 - 761
  • [30] THE PREVALENCE OF NOSOCOMIAL INFECTION IN INTENSIVE-CARE UNITS IN EUROPE - RESULTS OF THE EUROPEAN PREVALENCE OF INFECTION IN INTENSIVE-CARE (EPIC) STUDY
    VINCENT, JL
    BIHARI, DJ
    SUTER, PM
    BRUINING, HA
    WHITE, J
    NICOLASCHANOIN, MH
    WOLFF, M
    SPENCER, RC
    HEMMER, M
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (08): : 639 - 644