Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill

被引:299
作者
Reinhart, K
Kuhn, HJ
Hartog, C
Bredle, DL
机构
[1] Univ Jena, Dept Anesthesia & Intens Care Med, D-07747 Jena, Germany
[2] Univ Wisconsin, Dept Kinesiol, Eau Claire, WI 54701 USA
关键词
central venous oxygen saturation; mixed venous oxygen saturation; fiberoptic; oximetry;
D O I
10.1007/s00134-004-2337-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To compare the course of continuously measured mixed and central venous O-2 saturations in high-risk patients and to evaluate the impact of various factors that might interfere with reflection spectrophotometry. Design and setting. Prospective, descriptive study in the interdisciplinary ICU of a university hospital. Patients. 32 critically ill patients with triple-lumen central vein catheters, including 29 patients requiring pulmonary artery catheterization. Interventions. The accuracy of fiberoptic measurements was assessed by comparison to reference co-oximeter results at regular intervals. We examined the effect on measurement accuracy of physiological variables including hematocrit, hemoglobin, pH, temperature, and the administration of various solutions via central venous catheter. Continuous parallel measurements of SvO(2) and ScvO(2) were performed in patients with each type of catheters over a total observation time of 1097 h. Results. ScvO(2) values were more accurate and stable than in vitro oximeter measurements (r=0.96 from 150 samples, mean difference 0.15%, average drift 0.10%/day) and was not significantly affected by synchronous infusion therapy or by changes in hematocrit, hemoglobin, pH, or temperature. ScvO(2) values closely paralleled SvO(2), whether measured in vitro (r=0.88 from 150 samples) or in vivo (r=0.81 from 395,128 samples) but averaged about 7+/-4 saturation percentage higher. ScvO(2) changed in parallel in 90% of the 1,498 instances in which SvO(2) changed more than 5% (over an average of 43 min). Conclusions. Continuous fiberoptic measurement of central vein O-2 saturation has potential to be a reliable and convenient tool which could rapidly warn of acute change in the oxygen supply/demand ratio of critically ill patients.
引用
收藏
页码:1572 / 1578
页数:7
相关论文
共 36 条
[1]  
BEALE PL, 1982, ANESTH ANALG, V61, P513
[2]   CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN HEMODYNAMICALLY UNSTABLE PATIENTS [J].
BIRMAN, H ;
HAQ, A ;
HEW, E ;
ABERMAN, A .
CHEST, 1984, 86 (05) :753-756
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
CONNORS AF, 1996, JAMA-J AM MED ASSOC, V276, P8889
[5]   HEMODYNAMIC AND OXYGEN-TRANSPORT VARIABLES IN CARDIOGENIC-SHOCK SECONDARY TO ACUTE MYOCARDIAL-INFARCTION, AND RESPONSE TO TREATMENT [J].
CREAMER, JE ;
EDWARDS, JD ;
NIGHTINGALE, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (20) :1297-1300
[6]   CENTRAL MIXED AND SPLANCHNIC VENOUS OXYGEN-SATURATION MONITORING [J].
DAHN, MS ;
LANGE, MP ;
JACOBS, LA .
INTENSIVE CARE MEDICINE, 1988, 14 (04) :373-378
[7]   Is it time to pull the pulmonary artery catheter? [J].
Dalen, JE ;
Bone, RC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :916-918
[8]  
DESEPIBUS G, 1975, SCHWEIZ MED WSCHR, V105, P1445
[9]   Importance of the sampling site for measurement of mixed venous oxygen saturation in shock [J].
Edwards, JD ;
Mayall, RM .
CRITICAL CARE MEDICINE, 1998, 26 (08) :1356-1360
[10]   OXYGEN-TRANSPORT IN CARDIOGENIC AND SEPTIC SHOCK [J].
EDWARDS, JD .
CRITICAL CARE MEDICINE, 1991, 19 (05) :658-663