An episode of increased hemolysis due to a defective pneumatic air tube delivery system

被引:38
作者
Ellis, Graham [1 ]
机构
[1] St Johns Hosp, Dept Clin Biochem, Livingston W Lothian EH54 6PP, Scotland
关键词
Blood chemical analysis; Blood specimen collection; Humans; Reproducibility of results; Transportation; Hemolysis; Laboratories; Hospital; Specimen handling; Potassium/blood; BLOOD-GAS SAMPLES; TURNAROUND TIME; OXYGEN-TENSION; TRANSPORT; SPECIMENS; INTERFERENCE; BUBBLES; BANK;
D O I
10.1016/j.clinbiochem.2009.05.002
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To study an episode of excessive sample hemolysis associated with a recently installed pneumatic tube system from the Accident and Emergency Department. Design and methods: Hemolysis rates in samples delivered with a tube system installed 3-4 months previously were followed up retrospectively and prospectively. The laboratory database was searched over a 3-year period for serum potassium results and the number of hemolyzed samples rejected that had been delivered by pneumatic tube or by hand. Results: Before the tube system was installed, the weekly mean hemolysis rate was 3.3%. After installation, the rate was 10.9% for 12 weeks but then it increased to 54%. After a fault was corrected, values fell to 9.0% and to 7.1% after samples were bubble-wrapped. Other wards served as controls. Conclusion: Laboratories should be aware that defects may arise in tube systems that may result in rapid sample deceleration and excessive hemolysis. (C) 2009 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1265 / 1269
页数:5
相关论文
共 22 条
  • [1] Astles JR, 1996, ARCH PATHOL LAB MED, V120, P642
  • [2] USE OF A PNEUMATIC TUBE IN ANATOMIC PATHOLOGY
    BROOKS, JJ
    HAMILTON, B
    LIVOLSI, VA
    PIETRA, GG
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1986, 86 (05) : 669 - 673
  • [3] BRUNER KW, 1980, AM J CLIN PATHOL, V73, P593
  • [4] Changes in blood gas samples produced by a pneumatic tube system
    Collinson, PO
    John, CM
    Gaze, DC
    Ferrigan, LF
    Cramp, DG
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2002, 55 (02) : 105 - 107
  • [5] Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality
    Fernandes, CMB
    Worster, A
    Eva, K
    Hill, S
    McCallum, C
    [J]. JOURNAL OF EMERGENCY NURSING, 2006, 32 (02) : 139 - 143
  • [6] GREEN M, 1995, ARCH PATHOL LAB MED, V119, P943
  • [7] The impact of a pneumatic tube and computerized physician order management on laboratory turnaround time
    Guss, David A.
    Chan, Theodore C.
    Killeen, James P.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2008, 51 (02) : 181 - 185
  • [8] EMERGENCY TRANSPORT OF AS-1 RED-CELL UNITS BY PNEUMATIC TUBE SYSTEM
    HARDIN, G
    QUICK, G
    LADD, DJ
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1990, 30 (03) : 346 - 348
  • [9] Pseudohyperkalemia due to pneumatic tube transport in a leukemic patient
    Kellerman, PS
    Thornbery, JM
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2005, 46 (04) : 746 - 748
  • [10] EVALUATION OF A SOFT-HANDLING COMPUTERIZED PNEUMATIC TUBE SPECIMEN DELIVERY SYSTEM - EFFECTS ON ANALYTICAL RESULTS AND TURNAROUND TIME
    KESHGEGIAN, AA
    BULL, GE
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1992, 97 (04) : 535 - 540