Comparison between an automatic and a visual scoring method of the chin muscle tone during rapid eye movement sleep

被引:51
作者
Ferri, Raffaele [1 ]
Gagnon, Jean-Francois [2 ,3 ]
Postuma, Ronald B. [2 ,4 ]
Rundo, Francesco [1 ]
Montplaisir, Jacques Y. [2 ,5 ]
机构
[1] Oasi Inst IRCCS, Sleep Res Ctr, Dept Neurol IC, I-94018 Troina, Italy
[2] Hop Sacre Coeur, Ctr Etud Avancees Med Sommeil, Montreal, PQ H4J 1C5, Canada
[3] Univ Quebec, Dept Psychol, Montreal, PQ H3C 3P8, Canada
[4] McGill Univ, Montreal Gen Hosp, Dept Neurol, Montreal, PQ H3G 1A4, Canada
[5] Univ Montreal, Dept Psychiat, Montreal, PQ H3C 3J7, Canada
基金
加拿大健康研究院;
关键词
REM sleep behavior disorder; Atonia index; REM sleep without atonia; Tonic chin EMG; Phasic chin EMG; Automatic analysis; BEHAVIOR DISORDER; EMG AMPLITUDE; NEURODEGENERATIVE DISEASE; QUANTITATIVE-ANALYSIS; NIGHT VARIABILITY; DREAMS; ATONIA;
D O I
10.1016/j.sleep.2013.12.022
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To compare two different methods, one visual and the other automatic, for the quantification of rapid eye movement (REM) sleep without atonia (RSWA) in the diagnosis of REM sleep behavior disorder (RBD). Methods: Seventy-four RBD patients (mean age, 62.14 +/- 9.67 years) and 75 normal controls (mean age, 61.04 +/- 12.13 years) underwent one night video-polysomnographic recording. The chin electromyogram (EMG) during REM sleep was analyzed by means of a previously published visual method quantifying the percentage of 30 s epochs scored as tonic (abnormal, >= 30%) and that of 2 s mini-epochs containing phasic EMG events (abnormal, >= 15%). For the computer quantitative analysis we used the automatic scoring,algorithm known as the atonia index (abnormal, <0.8). The percentage correct classification, sensitivity, specificity, and Cohen kappa were calculated. Results: The atonia index correctly classified 82.6% of subjects, similar to the percentage of correct classifications with individual components of the visual analysis (83.2% each for tonic and phasic), and the combined visual parameters (85.9%). The sensitivity and specificity of automatic analysis (84% and 81%) was similar to the combined visual analysis (89% and 83%). The correlation coefficient between the automatic atonia index and the percentage of visual tonic EMG was high (r = -0.886, P < 0.00001), with moderately high correlation with the percentage of phasic EMG (r = -0.690, P < 0.00001). The agreement between atonia index and the visual parameters (individual or combined) was approximately 85% with Cohen's kappa, ranging from 0.638 to 0.693. Conclusion: Sensitivity, specificity, and correct classifications were high with both methods. Moreover, there was general agreement between methods, with Cohen's kappa values in the 'good' range. Given the considerable practical advantages of automatic quantification of REM atonia, automatic quantification may be a useful alternative to visual scoring methods in otherwise uncomplicated polysomnograms. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:661 / 665
页数:5
相关论文
共 24 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R, DOI DOI 10.1201/9780429258589
[2]  
[Anonymous], ED PSYCHOL MEASUREME
[3]  
[Anonymous], 2005, INT CLASSIFICATION S
[4]   Pathophysiology of REM sleep behaviour disorder and relevance to neurodegenerative disease [J].
Boeve, B. F. ;
Silber, M. H. ;
Saper, C. B. ;
Ferman, T. J. ;
Dickson, D. W. ;
Parisi, J. E. ;
Benarroch, E. E. ;
Ahlskog, J. E. ;
Smith, G. E. ;
Caselli, R. C. ;
Tippman-Peikert, M. ;
Olson, E. J. ;
Lin, S. -C. ;
Young, T. ;
Wszolek, Z. ;
Schenck, C. H. ;
Mahowald, M. W. ;
Castillo, P. R. ;
Del Tredici, K. ;
Braak, H. .
BRAIN, 2007, 130 :2770-2788
[5]  
Cygan F, 2010, J CLIN SLEEP MED, V6, P551
[6]  
Fern R, 2013, SLEEP MED, V14, P24
[7]  
Ferri R, 2008, SLEEP, V31, P1409
[8]   A quantitative statistical analysis of the submentalis muscle EMG amplitude during sleep in normal controls and patients with REM sleep behavior disorder [J].
Ferri, Raffaele ;
Manconi, Mauro ;
Plazzi, Giuseppe ;
Bruni, Oliviero ;
Vandi, Stefano ;
Montagna, Pasquale ;
Ferini-Strambi, Luigi ;
Zucconi, Marco .
JOURNAL OF SLEEP RESEARCH, 2008, 17 (01) :89-100
[9]   Effects of long-term use of clonazepam on nonrapid eye movement sleep patterns in rapid eye movement sleep behavior disorder [J].
Ferri, Raffaele ;
Zucconi, Marco ;
Marelli, Sara ;
Plazzi, Giuseppe ;
Schenck, Carlos H. ;
Ferini-Strambi, Luigi .
SLEEP MEDICINE, 2013, 14 (05) :399-406
[10]   Night-to-Night Variability of Automatic Quantitative Parameters of the Chin EMg Amplitude (Atonia Index) in REM Sleep Behavior Disorder [J].
Ferri, Raffaele ;
Marelli, Sara ;
Cosentino, Filomena I. I. ;
Rundo, Francesco ;
Ferini-Strambi, Luigi ;
Zucconi, Marco .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (03) :253-258