High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator

被引:99
|
作者
Korte, T
Köditz, H
Niehaus, M
Paul, T
Tebbenjohanns, J
机构
[1] Hannover Med Sch, Dept Cardiol & Pediat Cardiol, D-30625 Hannover, Germany
[2] Med Univ S Carolina, Dept Pediat Cardiol, Charleston, SC USA
来源
关键词
implantable cardioverter defibrillator; pediatric cardiology; appropriate and inappropriate therapies;
D O I
10.1111/j.1540-8159.2004.00560.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Appropriate and inappropriate therapies of implantable cardioverter defibrillators have a major impact on morbidity and quality of life in ICD recipients, but have not been systematically studied in children and young adults during long-term follow-up. ICD implantation was performed in 20 patients at the mean age of 16 +/- 6 years, 11 of which had prior surgical repair of a congenital heart defect, 9 patients had other cardiac diseases. Implant indications were aborted sudden cardiac death in six patients, recurrent ventricular tachycardia in 9 patient, and syncope in 5 patients. Epicardial implantation was performed in 6 and transvenous implantation in 14 patients. Incidence, reasons and predictors (age, gender, repaired congenital heart disease, history of supraventricular tachycardia, and epicardial electrode system) of appropriate and inappropriate ICD therapies were analyzed during a mean follow-up period of 51 +/- 31 months range 18-132 months. There were a total 239 ICD therapies in 17 patients (85%) with a therapy rate of 2.8 per patient-years of follow-up. 127 (53%)ICD therapies in 15 (75%) patients were catagorized as appropriate and 112 (47%) therapies in 10 (50%) patients us inappropriate, with a rate of 1.5 appropriate and 1.3 inappropriate ICD therapies per patient-years of follow-up. Time to first appropriate therapy was 16 +/- 18 months. Appropriate therapies were caused by ventricular fibrillation in 29 and ventricular tachycardia in 98 episodes. Termination was successful by antitachycardia pacing in 4 (3%) and by shock therapy in 123 episodes (97%). Time to first inappropriate therapy was 16 +/- 17 months. Inappropriate therapies were caused by supraventricular tachycardia in 77 (69%), T wave oversensing in 19 (17%), and electrode defect in 16 episodes (14%). It caused shocks in 87 (78%) and only antitachycardia pacing in 25 episodes (22%). No clinical variable could be identified as predictor of either appropriate or inappropriate ICD therapies. There is a high rate of ICD therapies in young ICD recipients, the majority of which occur during early follow-up. The rate of inappropriate therapies is as high as 47% and is caused by supraventricular tachycardia and electrode complications in the majority of cases. Prospective trials ore required to establish preventative startegies of ICD therapies in this young patient population.
引用
收藏
页码:924 / 932
页数:9
相关论文
共 50 条
  • [21] Troubleshooting of inappropriate therapies in patients with implantable cardioverter-defibrillator - a case report
    Walter, T
    Kluge, P
    Neugebauer, A
    Pfeiffer, D
    HERZ KREISLAUF, 1997, 29 (10): : 293 - 296
  • [22] Audit of implantable cardioverter defibrillator (ICD) shocks
    Llewellyn, Chris
    Chieng, Vui Yung
    Affolter, Jonathan
    SCOTTISH MEDICAL JOURNAL, 2016, 61 (04) : NP39 - NP40
  • [23] Prescribing Exercise With an Implantable Cardioverter Defibrillator (ICD)
    Flo, Gayle
    Dougherty, Cynthia M.
    Glenny, Robb
    Kudenchuk, Peter J.
    CIRCULATION, 2009, 120 (18) : S434 - S434
  • [24] Indications for implantable cardioverter defibrillator (ICD) therapy
    Hauer, RNW
    Aliot, E
    Block, M
    Capucci, A
    Lüderitz, B
    Santini, M
    Vardas, PE
    EUROPACE, 2001, 3 (03): : 169 - 176
  • [25] Electrocardiographic predictors of appropriate implantable cardioverter defibrillator therapies in patients with tetralogy of Fallot
    Waldmann, V.
    Bouzeman, A.
    Koutbi, R.
    Bessiere, F.
    Hermida, A.
    Duthoit, G.
    Elbaz, N.
    Messali, A.
    De Guillebon, M.
    Mansourati, J.
    Da Costa, A.
    Martins, R.
    Gourraud, J. B.
    Combes, N.
    Marijon, E.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3118 - 3118
  • [26] Recollection of Pain Due to Inappropriate Versus Appropriate Implantable Cardioverter-Defibrillator Shocks
    Marcus, Gregory M.
    Chan, Derrick W.
    Redberg, Rita F.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (03): : 348 - 353
  • [27] Biventricular implantable cardioverter defibrillator and inappropriate shocks
    Srivathsan, K
    Bazzell, JL
    Lee, RW
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (01) : 88 - 89
  • [28] Implantable Cardioverter-Defibrillator Shock during Physical Activity: Appropriate or Inappropriate Shock?
    Chemello, Diego
    Chin, Ashley
    Morillo, Carlos
    Divakaramenon, Syamkumar
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (05): : 635 - 638
  • [29] Inappropriate implantable cardioverter defibrillator shocks—incidence, effect, and implications for driver licensing
    Eiichi Watanabe
    Katsunori Okajima
    Akira Shimane
    Tomoya Ozawa
    Tetsuyuki Manaka
    Itsuro Morishima
    Toru Asai
    Masahiko Takagi
    Toshihiro Honda
    Atsunobu Kasai
    Eitaro Fujii
    Kohei Yamashiro
    Ritsuko Kohno
    Haruhiko Abe
    Takashi Noda
    Takashi Kurita
    Shigeyuki Watanabe
    Hiroya Ohmori
    Takashi Nitta
    Yoshifusa Aizawa
    Ken Kiyono
    Ken Okumura
    Journal of Interventional Cardiac Electrophysiology, 2017, 49 : 271 - 280
  • [30] Right Ventricular Dysfunction and the Incidence of Implantable Cardioverter-Defibrillator Therapies
    Aktas, Mehmet K.
    Kim, David D.
    McNitt, Scott
    Huang, David T.
    Rosero, Spencer Z.
    Hall, Burr W.
    Zareba, Wojciech
    Daubert, James P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (12): : 1501 - 1508