Contrast-Enhanced Ultrasonography and Color Doppler: Guided Intraoperative Embolization of Intracranial Highly Vascularized Tumors

被引:13
|
作者
Della Pappa, Giuseppe Maria [1 ]
Marchese, Enrico [1 ]
Pedicelli, Alessandro [2 ]
Olivi, Alessandro [1 ]
Ricciardi, Luca [1 ]
Rapisarda, Alessandro [1 ]
Skrap, Benjamin [1 ]
Sabatino, Giovanni [1 ,3 ]
La Rocca, Giuseppe [1 ,3 ]
机构
[1] Univ Cattolica Sacro Cuore, Inst Neurosurg, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Inst Neuroradiol, Rome, Italy
[3] Mater Olbia Hosp, Neurosurg Unit, Olbia, Italy
关键词
Brain tumor; Color Doppler; Contrast-enhanced ultrasonography; Hemangioblastoma; Intraoperative embolization; Ultrasonography; INDOCYANINE GREEN VIDEOANGIOGRAPHY; DURAL ARTERIOVENOUS-FISTULAS; PREOPERATIVE EMBOLIZATION; EFSUMB GUIDELINES; CLINICAL-PRACTICE; ULTRASOUND CEUS; DIRECT PUNCTURE; HEMANGIOPERICYTOMA; RECOMMENDATIONS; RESECTION;
D O I
10.1016/j.wneu.2019.05.142
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Preoperative embolization is often considered mandatory in highly vascularized brain tumors to contain blood loss. However, not all lesions are amenable to endovascular preoperative embolization. In the literature, cases of preoperative and intraoperative embolization are described only by arterial catheterization, whereas experiences of tumor embolization through direct puncture of the lesion are anecdotal; furthermore these cases lack an intraoperative control method to assess the effects of the embolizing procedure itself. METHODS: We describe the association of contrast enhanced ultrasonography (CEUS) and color Doppler ultrasonography (CDUS) to perform intraoperative embolization in an illustrative case of a posterior cranial fossa hemangioblastoma not amenable to a preoperative endovascular procedure. The combination of CEUS and CDUS was tested as an option for the intraoperative devascularization of tumors in which preoperative embolization is considered risky or not possible. RESULTS: The association of CEUS and CDUS provided real-time intraoperative data that directly guided the intraoperative embolization and provided reliable data about the hemodynamic effects produced after the direct injection of an embolizing agent. The technique offered a true real-time definition of the anatomic characteristics of the lesion and its relationships with the adjacent structures while distinguishing feeding from draining vessels. CONCLUSIONS: This technique has been proved to be a valuable tool in the surgical resection of highly vascularized tumors and in the treatment of intracranial and spinal vascular lesions and can be considered an option in those cases in which preoperative embolization is not possible. It is a feasible, modern, and cost-effective intraoperative imaging technique that allows identification of unexposed anatomic structures, hence minimizing surgical exposition and surgical manipulation.
引用
收藏
页码:547 / 555
页数:9
相关论文
共 50 条
  • [21] Contrast-enhanced Ultrasonography in Small Liver Tumors (< 3 cm)
    Wang, Jing-Houng
    Changchien, Chi-Sin
    JOURNAL OF MEDICAL ULTRASOUND, 2008, 16 (01) : 26 - 40
  • [22] Conventional, Doppler and Contrast-Enhanced Ultrasonography in Differential Diagnosis of Ovarian Masses
    Liu, Zongyu
    Yang, Fan
    Zhang, Yong
    Yu, Huimei
    Zhu, He
    Yang, Ruiqi
    Fan, Limei
    CELLULAR PHYSIOLOGY AND BIOCHEMISTRY, 2016, 39 (06) : 2398 - 2408
  • [23] Application of Intraoperative Contrast-Enhanced Ultrasound in the Resection of Brain Tumors
    Tao, An-yu
    Chen, Xu
    Zhang, Ling-yun
    Chen, Yong
    Cao, Dan
    Guo, Zheng-qian
    Chen, Jian
    CURRENT MEDICAL SCIENCE, 2022, 42 (01) : 169 - 176
  • [24] Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis
    Szkudlarek, M
    Court-Payen, M
    Strandberg, C
    Klarlund, M
    Klausen, T
    Ostergaard, M
    EUROPEAN RADIOLOGY, 2003, 13 (01) : 163 - 168
  • [25] Application of Intraoperative Contrast-Enhanced Ultrasound in the Resection of Brain Tumors
    An-yu Tao
    Xu Chen
    Ling-yun Zhang
    Yong Chen
    Dan Cao
    Zheng-qian Guo
    Jian Chen
    Current Medical Science, 2022, 42 : 169 - 176
  • [26] Clinical Usefulness of Contrast-Enhanced Color Doppler Ultrasonography in Invasive and Noninvasive Gestational Trophoblastic Diseases A Preliminary Study
    Emoto, Makoto
    Sadamori, Riko
    Hachisuga, Toru
    Kawarabayashi, Tatsuhiko
    Miyamoto, Shingo
    JOURNAL OF REPRODUCTIVE MEDICINE, 2011, 56 (5-6) : 224 - 234
  • [27] Is Routine Intraoperative Contrast-Enhanced Ultrasonography Useful During Whole Liver Transplantation?
    Golse, Nicolas
    Santoni, Simone
    Karam, Vincent
    Ciacio, Oriana
    Pittau, Gabriella
    Allard, Marc-Antoine
    Cherqui, Daniel
    Cunha, Antonio Sa
    Adam, Ren
    Castaing, Denis
    Vibert, Eric
    WORLD JOURNAL OF SURGERY, 2018, 42 (05) : 1523 - 1535
  • [28] Contrast-enhanced ultrasonography compared to gray-scale and power doppler in the diagnosis of peripheral lymphadenopathy
    Slaisova, Radka
    Benda, Karel
    Jarkovsky, Jiri
    Petrasova, Hana
    Szturz, Petr
    Valek, Vlastimil
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : 693 - 698
  • [29] "Dark corridors" in 5-ALA resection of high-grade gliomas: combining fluorescence-guided surgery and contrast-enhanced ultrasonography to better explore the surgical field
    Della Pepa, Giuseppe M.
    Ius, Tamara
    Menna, Grazia
    La Rocca, Giuseppe
    Battistella, Claudio
    Rapisarda, Alessandro
    Mazzucchi, Edoardo
    Pignotti, Fabrizio
    Alexandre, Andrea
    Marchese, Enrico
    Olivi, Alessandro
    Sabatino, Giovanni
    JOURNAL OF NEUROSURGICAL SCIENCES, 2019, 63 (06) : 688 - 696
  • [30] Perfusion analysis of benign parotid gland tumors by contrast-enhanced ultrasonography (CEUS)