Design Strategy of Fluorescent Probes for Live Drug-Induced Acute Liver Injury Imaging

被引:158
|
作者
Cheng, Dan [1 ,2 ]
Xu, Wang [1 ]
Gong, Xiangyang [1 ]
Yuan, Lin [1 ]
Zhang, Xiao-Bing [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemobiosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
[2] Univ South China, Affiliated Nanhua Hosp, Clin Res Inst, Hengyang 421002, Peoples R China
基金
中国博士后科学基金; 国家重点研发计划;
关键词
INDUCED HEPATOTOXICITY; PEROXYNITRITE; MITOCHONDRIA; PERSULFIDES; TOXICITY; PATHWAY; STRESS; CANCER; UNIQUE;
D O I
10.1021/acs.accounts.0c00646
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Drug-induced acute liver injury (DIALI) is increasingly recognized as a significant cause of acute liver injury (ALI), which is characterized by a rapid loss of hepatocyte function in patients without pre-existing liver diseases. Evaluation of corresponding biomarkers, including alanine transaminase and aspartate amino transferase, is available as a diagnostic tool for hepatotoxicity. However, these blood tests have certain limitations: (1) they are generally not available for early estimation; (2) it is difficult to visualize and identify hepatotoxicity unambiguously in real-time; and (3) the biomarkers are not unique and are usually influenced by a variety of diseases, leading to potential false results. It is of grave importance and burgeoning demand to develop an early diagnostic approach for such diseases, but the ideal toolkit remains an unresolved challenge. As an alternative, molecular optical probes (fluorescence, chemiluminescence, bioluminescence, etc.) display a lot of advantages, such as high sensitivity, noninvasive fast analysis, and real-time in situ detection. They have emerged as potent and promising tools for the biomedical study of DIALI in living system. Until now, a number of optical probes for DIALI have been reported with some great potential for clinical trials. However, most of the probes still suffer from false signals because of the limitations in clinical application, including poor selectivity, low sensitivity, and biocompatibility. One key challenge that probes face in the ALI environment is the excessive exposure to reactive oxygen/nitrogen species and diffusivity, which may lead to false-positive or negative signals. Our group has employed multiple rational approaches to engineer high-performance optical probes for DIALI. With such development, we have successfully achieved the accurate detection of DIALI with minimal false signals both ex vivo and in vivo. While marching firmly toward understanding the biogenesis and progression of DIALI, we ultimately aim at the early stage dinical diagnosis of the disease, as well as mechanism understanding for clinical trials. In this Account, we summarize and present our three new approaches for the development of high-fidelity optical probes: (1) a combined screening and rational design strategy, (2) a double-locked probe design strategy, and (3) in situ imaging based on the release of a precipitating fluorochrome strategy. Using these strategies, we have formulated probes for a range of biological species that are biomarkers of DIALI, including reactive nitrogen species (ONOO-), reactive sulfur species (H2S and H2Sn), and enzymes (LAP, MAO, and ALP). We have highlighted the rationale for our design and screening strategy and methods to achieve high-fidelity optical probes. Some recent examples of optical probes developed by our laboratory and collaborations are mainly illustrated herein. We anticipate the strategies summarized here to inspire future molecular optical probe design, to contribute to studies of the detailed molecular mechanisms underlying liver diseases, and to improve the efficiency of the diagnosis and treatment of these diseases in clinical settings.
引用
收藏
页码:403 / 415
页数:13
相关论文
共 50 条
  • [1] Chemical probes for drug-induced liver injury imaging
    Jiang, Tao
    Rong, Pengfei
    Wang, Wei
    FUTURE MEDICINAL CHEMISTRY, 2020, 12 (09) : 835 - 852
  • [2] Recent advance of fluorescent probes for detection of drug-induced liver injury markers
    Sun, Dongqin
    Chen, Zhenzhen
    Hu, Jiali
    Zeng, Huajin
    Qu, Lingbo
    Yang, Ran
    CHINESE CHEMICAL LETTERS, 2022, 33 (10) : 4478 - 4494
  • [3] Recent advance of fluorescent probes for detection of drug-induced liver injury markers
    Dongqin Sun
    Zhenzhen Chen
    Jiali Hu
    Huajin Zeng
    Lingbo Qu
    Ran Yang
    ChineseChemicalLetters, 2022, 33 (10) : 4478 - 4494
  • [4] Emerging fluorescent probes for bioimaging of drug-induced liver injury biomarkers: Recent advances
    Jiang, Qingqing
    Chen, Ran
    Li, Meng
    Zhang, Tianyu
    Kong, Ziyuzhu
    Ma, Kaifu
    Ye, Chao
    Sun, Xiaohan
    Shu, Wei
    BIOORGANIC CHEMISTRY, 2025, 159
  • [5] Activatable Optical Probes for Fluorescence and Photoacoustic Imaging of Drug-Induced Liver Injury
    Chen, Linrong
    Zhen, Xu
    Jiang, Xiqun
    ADVANCED NANOBIOMED RESEARCH, 2022, 2 (12):
  • [6] Fluorescent probe for the imaging of superoxide and peroxynitrite during drug-induced liver injury
    Wu, Luling
    Liu, Jihong
    Tian, Xue
    Groleau, Robin R.
    Bull, Steven D.
    Li, Ping
    Tang, Bo
    James, Tony D.
    CHEMICAL SCIENCE, 2021, 12 (11) : 3921 - 3928
  • [7] Molecular optical imaging probes for early diagnosis of drug-induced acute kidney injury
    Huang, Jiaguo
    Li, Jingchao
    Lyu, Yan
    Miao, Qingqing
    Pu, Kanyi
    NATURE MATERIALS, 2019, 18 (10) : 1133 - +
  • [8] Acute, serious drug-induced liver injury
    Gluud, C
    JOURNAL OF HEPATOLOGY, 2002, 37 (05) : 675 - 677
  • [9] Molecular optical imaging probes for early diagnosis of drug-induced acute kidney injury
    Jiaguo Huang
    Jingchao Li
    Yan Lyu
    Qingqing Miao
    Kanyi Pu
    Nature Materials, 2019, 18 : 1133 - 1143