Mapping the antioxidant activity of apple peels with soft probe scanning electrochemical microscopy

被引:17
作者
Lin, Tzu-En [1 ]
Lesch, Andreas [1 ]
Li, Chi-Lin [2 ]
Girault, Hubert H. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, EPFL Valais Wallis, Lab Electrochim Phys & Analyt, Rue Ind 17,Case Postale 440, CH-1951 Sion, Switzerland
[2] Natl Taiwan Univ, Dept Chem, 1,Sect 4,Roosevelt Rd, Taipei 10617, Taiwan
基金
瑞士国家科学基金会;
关键词
Scanning electrochemical microscopy; Soft probes; Microelectrodes; Antioxidants; Apple peel; CONSTANT-DISTANCE MODE; PUSH-PULL PROBE; SOLUBLE ANTIOXIDANTS; FRAP ASSAY; FRUIT; SECM; CANCER; NANOPARTICLES; DISCOLORATION; FLUORESCENCE;
D O I
10.1016/j.jelechem.2017.01.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a non-invasive electrochemical strategy for mapping the antioxidant (AO) activity of apple peels, which counterbalances oxidative stress caused by various external effectors. Soft carbon microelectrodes were used for soft probe scanning electrochemical microscopy (SECM) enabling the gentle and scratch-free contact mode scanning of rough and delicate apple peels in an electrolyte solution. The SECM feedback mode was applied using ferrocene methanol (FcMeOH) as redox mediator that gets electrochemically oxidized at the soft probe and diffuses towards the apple peel where it gets regenerated by certain AOs leading to a redox mediator recyding and increased current signal. The global AO activity in the apple peel including lenticels and regions with artificially degraded AOs were mapped using the soft microelectrodes. Finally, in an apple cross-section the higher and homogeneous AO concentration in the peel with a heterogeneously decaying AO gradient towards the apple inward was visualized, demonstrating the adequate micrometer resolution of the SECM probe and the possibility to get information of the interior AO activity of the apple. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:120 / 128
页数:9
相关论文
共 71 条
  • [1] Scanning Electrochemical Microscopy
    Amemiya, Shigeru
    Bard, Allen J.
    Fan, Fu-Ren F.
    Mirkin, Michael V.
    Unwin, Patrick R.
    [J]. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 (01) : 95 - 131
  • [2] ACCUMULATION OF ANTIOXIDANTS IN APPLE PEEL AS RELATED TO PREHARVEST FACTORS AND SUPERFICIAL SCALD SUSCEPTIBILITY OF THE FRUIT
    BARDEN, CL
    BRAMLAGE, WJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR HORTICULTURAL SCIENCE, 1994, 119 (02) : 264 - 269
  • [3] The ferric reducing ability of plasma (FRAP) as a measure of ''antioxidant power'': The FRAP assay
    Benzie, IFF
    Strain, JJ
    [J]. ANALYTICAL BIOCHEMISTRY, 1996, 239 (01) : 70 - 76
  • [4] Non-destructive evaluation of ripening and quality traits in apples using a multiparametric fluorescence sensor
    Betemps, Debora L.
    Carlos Fachinello, Jose
    Galarca, Simone P.
    Portela, Nicacia M.
    Remorini, Damiano
    Massai, Rossano
    Agati, Giovanni
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2012, 92 (09) : 1855 - 1864
  • [5] Anatomical investigation of lenticel development and subsequent discolouration of 'Tommy Atkins' and 'Keitt' mango (Mangifera indica L.) fruit
    Bezuidenhout, JLJ
    Robbertse, PJ
    Kaiser, C
    [J]. JOURNAL OF HORTICULTURAL SCIENCE & BIOTECHNOLOGY, 2005, 80 (01) : 18 - 22
  • [6] Electrochemical Push-Pull Probe: From Scanning Electrochemical Microscopy to Multimodal Altering of Cell Microenvironment
    Bondarenko, Alexandra
    Cortes-Salazar, Fernando
    Gheorghiu, Mihaela
    Gaspar, Szilveszter
    Momotenko, Dmitry
    Stanica, Luciana
    Lesch, Andreas
    Gheorghiu, Eugen
    Girault, Hubert H.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (08) : 4479 - 4486
  • [7] A chronoamperometric method for determining total antioxidant activity
    Brainina, Kh. Z.
    Varzakova, D. P.
    Gerasimova, E. L.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 67 (04) : 364 - 369
  • [8] Soft Microelectrode Linear Array for Scanning Electrochemical Microscopy
    Cortes-Salazar, Fernando
    Momotenko, Dmitry
    Lesch, Andreas
    Wittstock, Gunther
    Girault, Hubert H.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (24) : 10037 - 10044
  • [9] Soft Stylus Probes for Scanning Electrochemical Microscopy
    Cortes-Salazar, Fernando
    Traeuble, Markus
    Li, Fei
    Busnel, Jean-Marc
    Gassner, Anne-Laure
    Hojeij, Mohamad
    Wittstock, Gunther
    Girault, Hubert H.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (16) : 6889 - 6896
  • [10] Development of Nano-Disc electrodes for Application as Shear Force Sensitive Electrochemical Probes
    Danis, Laurence
    Snowden, Michael E.
    Tefashe, Ushula M.
    Heinemann, Christian N.
    Mauzeroll, Janine
    [J]. ELECTROCHIMICA ACTA, 2014, 136 : 121 - 129