Tumor Tracking Method Based on a Deformable 4D CT Breathing Motion Model Driven by an External Surface Surrogate

被引:62
|
作者
Fassi, Aurora [1 ]
Schaerer, Joel [2 ,3 ]
Fernandes, Mathieu [2 ,3 ]
Riboldi, Marco [1 ,4 ]
Sarrut, David [2 ,3 ]
Baroni, Guido [1 ,4 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[2] Univ Lyon 1, CNRS UMR 5220, INSERM U1044, INSA Lyon,CREATIS, F-69622 Villeurbanne, France
[3] Ctr Leon Berard, Dept Radiotherapy, F-69373 Lyon, France
[4] CNAO Fdn, Bioengn Unit, Pavia, Italy
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2014年 / 88卷 / 01期
关键词
CONE-BEAM CT; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; LUNG-TUMORS; PARTICLE THERAPY; RADIOTHERAPY; SYSTEM; REGISTRATION; ACCURACY; UNCERTAINTIES;
D O I
10.1016/j.ijrobp.2013.09.026
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. Methods and Materials: The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional planning computed tomography (CT) images. Model parameters (respiratory baseline, amplitude, and phase) are retrieved and updated at each treatment fraction according to in-room radiography acquisition and optical surface imaging. The baseline parameter is adapted to the interfraction variations obtained from the daily cone beam (CB) CT scan. The respiratory amplitude and phase are extracted from an external breathing surrogate, estimated from the displacement of the patient thoracoabdominal surface, acquired with a noninvasive surface imaging device. The developed method was tested on a database of 7 lung cancer patients, including the synchronized information on internal and external respiratory motion during a CBCT scan. Results: About 30 seconds of simultaneous acquisition of CBCT and optical surface images were analyzed for each patient. The tumor trajectories identified in CBCT projections were used as reference and compared with the target trajectories estimated from surface displacement with the a priori motion model. The resulting absolute differences between the reference and estimated tumor motion along the 2 image dimensions ranged between 0.7 and 2.4 mm; the measured phase shifts did not exceed 7% of the breathing cycle length. Conclusions: We investigated a tumor tracking method that integrates breathing motion information provided by the 4-dimensional planning CT with surface imaging at the time of treatment, representing an alternative approach to point-based external-internal correlation models. Although an in-room radiograph-based assessment of the reliability of the motion model is envisaged, the developed technique does not involve the estimation and continuous update of correlation parameters, thus requiring a less intense use of invasive imaging. (C) 2014 Elsevier Inc.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 50 条
  • [1] Surrogate-driven deformable motion model for organ motion tracking in particle radiation therapy
    Fassi, Aurora
    Seregni, Matteo
    Riboldi, Marco
    Cerveri, Pietro
    Sarrut, David
    Ivaldi, Giovanni Battista
    de Fatis, Paola Tabarelli
    Liotta, Marco
    Baroni, Guido
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04): : 1565 - 1582
  • [2] Tumor motion tracking based on a four-dimensional computed tomography respiratory motion model driven by an ultrasound tracking technique
    Ting, Lai-Lei
    Chuang, Ho-Chiao
    Liao, Ai-Ho
    Kuo, Chia-Chun
    Yu, Hsiao-Wei
    Tsai, Hsin-Chuan
    Tien, Der-Chi
    Jeng, Shiu-Chen
    Chiou, Jeng-Fong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (01) : 26 - 39
  • [3] Tumor tracking in 4D CT images for adaptive radiotherapy
    Kronemeijer, Pieter S.
    Gavves, Efstratios
    Sonke, Jan-Jakob
    Teuwen, Jonas
    MEDICAL IMAGING 2022: IMAGE PROCESSING, 2022, 12032
  • [4] Influence of 4D CT Motion Artifacts on Correspondence Model-based 4D Dose Accumulation
    Sothmann, Thilo
    Gauer, Tobias
    Werner, Rene
    MEDICAL IMAGING 2018: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2018, 10576
  • [5] A 4D global respiratory motion model of the thorax based on CT images: A proof of concept
    Fayad, Hadi
    Gilles, Marlene
    Pan, Tinsu
    Visvikis, Dimitris
    MEDICAL PHYSICS, 2018, 45 (07) : 3043 - 3051
  • [6] Method for a motion model based automated 4D dose calculation
    Ziegler, Marc
    Brandt, Tobias
    Lettmaier, Sebastian
    Fietkau, Rainer
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22):
  • [7] 4D CT image reconstruction with diffeomorphic motion model
    Hinkle, Jacob
    Szegedi, Martin
    Wang, Brian
    Salter, Bill
    Joshi, Sarang
    MEDICAL IMAGE ANALYSIS, 2012, 16 (06) : 1307 - 1316
  • [8] Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model
    Marx, Mirko
    Ehrhardt, Jan
    Werner, Rene
    Schlemmer, Heinz-Peter
    Handels, Heinz
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (03) : 401 - 409
  • [9] Examination of a deformable motion model for respiratory movements and 4D dose calculations using different driving surrogates
    Woelfelschneider, Jens
    Seregni, Matteo
    Fassi, Aurora
    Ziegler, Marc
    Baroni, Guido
    Fietkau, Rainer
    Riboldi, Marco
    Bert, Christoph
    MEDICAL PHYSICS, 2017, 44 (06) : 2066 - 2076
  • [10] Image interpolation in 4D CT using a BSpline deformable registration model
    Schreibmann, E
    Chen, GTY
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05): : 1537 - 1550