Determination of chlorine dioxide in water by gas chromatography-mass spectrometry

被引:16
作者
Shinb, Ho-Sang [1 ]
Jung, Dong-Gyun
机构
[1] Kongju Natl Univ, Dept Environm Educ, Kong Ju, South Korea
[2] Kongju Natl Univ, Abuse Drug Res Ctr, Kong Ju, South Korea
[3] Kongju Natl Univ, Dept Environm Sci, Kong Ju 314701, South Korea
关键词
GC-MS; chlorine dioxide; determination; water;
D O I
10.1016/j.chroma.2006.04.089
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive gas chromatographic method has been established for the determination of chlorine dioxide in water. With weak basic conditions (pH 9.0), chlorine dioxide reacts with iodide to form iodine, which reacts with 2,6-dialkylphenol to form 4-iodo-2,6-dialkylphenol. The volatile organic derivative was extracted with ethyl acetate, and then measured by gas chromatography-mass spectrometry (GC-MS). The reaction of the active proton of 2,6-dialkylphenols (2,6-dimethylphenol, 2,6-di-isopropylphenol and 2,6-di-tert-butylphenol) with iodine was tested, and compared to each other in terms of reactivity and stability of the derivatives. 2,6-dimethylphenol showed rapid reaction with iodine, and its derivative was stable for 2 weeks. The detection limit of chlorine dioxide in water was about 1.0 ng/mL, and the calibration curve showed good linearity with r(2) = 0.998. The existent concentration of chlorine dioxide in water was calculated from multiplying the concentration calculated from the calibration curve of 4-iodo-2,6-dimethylphenol by 0.544. The method was sensitive, reproducible and simple enough to permit the reliable analysis of chlorine dioxide at the low ng/mL level in water. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 30 条
[11]  
Huang JL, 1997, WATER RES, V31, P455, DOI 10.1016/S0043-1354(96)00276-X
[12]  
HUE C, 1997, ANAL LETT, V30, P1415
[13]  
HUIE RE, 1986, J PHYS CHEM-US, V90, P1362
[14]   EFFECT OF DIMETHYLSULFOXIDE AS A MASKING AGENT FOR CHLORINE IN THE SELECTIVE DETERMINATION OF AQUEOUS CHLORINE DIOXIDE [J].
IMAIZUMI, N ;
NAKAHARA, Y ;
SUZUKI, K ;
OIKAWA, K .
CHEMISTRY LETTERS, 1993, (08) :1333-1336
[15]  
JALE BA, 1987, P AWWA WATER QUAL TE, V15, P1055
[16]   A new sensitive and selective fluorescence method for determination of chlorine dioxide in water using rhodamine S [J].
Jiang, ZL ;
Zhang, BM ;
Liang, AH .
TALANTA, 2005, 66 (03) :783-788
[17]   Development of chlorine dioxide-related by-product models for drinking water treatment [J].
Korn, C ;
Andrews, RC ;
Escobar, MD .
WATER RESEARCH, 2002, 36 (01) :330-342
[18]  
MANTISI F, 2000, Patent No. 985929
[19]  
NOWACK B, 1999, P AWWA WATER QUAL TE, V61, P1145
[20]  
Oikawa K., 1991, SODA ENSO, V42, P491