Imaging performance of silicon photomultipliers coupled to BGO and CsI: Na arrays

被引:6
作者
David, S. [1 ]
Georgiou, M. [1 ,2 ]
Fysikopoulos, E. [3 ]
Belcari, N. [4 ,5 ]
Loudos, G. [1 ]
机构
[1] Technol Educ Inst Athens, Dept Biomed Engn, Athens, Greece
[2] Univ Thessaly, Sch Med, Dept Nucl Med, Larisa, Greece
[3] Natl Tech Univ Athens, Sch Elect & Comp Engn, Athens, Greece
[4] Univ Pisa, Dept Phys E Fermi, Pisa, Italy
[5] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
关键词
Gamma detectors (scintillators; CZT; HPG; HgI etc); Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Photon detectors for UV; visible and IR photons (solid-state) (PIN diodes; APDs; Si-PMTs; G-APDs; CCDs; EBCCDs; EMCCDs etc);
D O I
10.1088/1748-0221/8/12/P12008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study is to investigate the imaging performance of a silicon photomultiplier array (ArraySL-4) photodetector for possible PET and potentially SPECT applications using BGO and CsI(Na) pixellated scintillators. Our main objectives are: i) the comparison of the ArraySL-4 to the older version SensL's SPMArray4 photo detector in terms of energy resolution and peak to valley ratio of a row profile in the flood image and ii) the study of the effect of different coupling schemes using ultra transmitting glass windows of various thicknesses. We acquired raw images from two pixellated scintillators (BGO with 2 x 2 x 5mm(3) and CsI: Na with 1 x 1 x 5mm(3) pixel sizes) irradiated with 511 keV and 1274.5 keV g -rays from a 22Na source. The SiPM array detector allowed the clear visualization of the discrete 2 x 2mm(2) pixellated BGO and 1 x 1mm(2) CsI: Na scintillator elements at room temperature (no cooling). The energy resolution of the new SensL ArraySL-4 detector for the 2 x 2 x 5mm(3) BGO pixellated scintillator array is improved for rather 6 percentage points (energy resolution improvement equal to 22%) and the peak to valley ratio is measured higher for both scintillator arrays (for BGO 68% (1 : 7 x) and for CsI: Na 154% (2 : 5 x)) compared with SPMArray4. The clear identification of the 1 x 1mm(2) CsI: Na scintillator elements provides evidence that the combination of those SiPMs with even smaller arrays can be used as an efficient imaging detector module. Optical coupling significantly improves image uniformity, while the use of BK7 ultra transmitting glass window with 1.35mm thickness provided the best measure energy resolution equal to 21.5%.
引用
收藏
页数:12
相关论文
共 21 条
[1]  
[Anonymous], [No title captured]
[2]   Silicon photomultiplier and its possible applications [J].
Buzhan, P ;
Dolgoshein, B ;
Filatov, L ;
Ilyin, A ;
Kantzerov, V ;
Kaplin, V ;
Karakash, A ;
Kayumov, F ;
Klemin, S ;
Popova, E ;
Smirnov, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3) :48-52
[3]   Improving time resolution in time-of-flight PET [J].
Conti, Maurizio .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 :S194-S198
[4]  
David S, 2011, IEEE NUCL SCI CONF R, P1886, DOI 10.1109/NSSMIC.2011.6154380
[5]   Calibration and stability of a SiPM-based simultaneous PET/MR insert [J].
Lerche, Christoph W. ;
Mackewn, Jane ;
Goldschmidt, Benjamin ;
Salomon, Andre ;
Gebbhardt, Pierre ;
Weissler, Bjoern ;
Ayres, Richard ;
Marsden, Paul ;
Schulz, Volkmar .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 :50-53
[6]   Energy and Timing Resolution Studies With Silicon Photomultipliers (SiPMs) and 4-Pixel SiPM Matrices for PET [J].
Llosa, Gabriela ;
Belcari, Nicola ;
Bisogni, Maria Giuseppina ;
Collazuol, Gianmaria ;
Marcatili, Sara ;
Moehrs, Sascha ;
Morsani, Fabio ;
Piemonte, Claudio ;
Del Guerra, Alberto .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) :543-548
[7]  
Majewski S., 2011, IEEE NUCL SCI C R, P3941
[8]   Advanced data readout technique for Multianode Position Sensitive Photomultiplier Tube applicable in radiation imaging detectors [J].
Popov, V. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[9]  
Popov V., 2003, NUCL SCI S C RECORD, V3, P2156, DOI DOI 10.1109/NSSMIC.2003.1352307
[10]   A novel readout concept for multianode photomultiplier tubes with pad matrix anode layout [J].
Popov, Vladimir ;
Majewski, Stan ;
Welch, Benjamin L. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01) :319-322