Humidity devices in vitreoretinal surgery

被引:7
|
作者
Franzco, BJTV
Newland, A
Polkinghorne, PJ
机构
[1] Auckland Hosp, Auckland Eye Dept, Dept Ophthalmol, Auckland, New Zealand
[2] Fisher & Paykel, Div Hlth Care, Auckland, New Zealand
关键词
dehydration injury; fluid-air exchange; humidity; visual field defect;
D O I
10.1097/00006982-200210000-00013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess a humidity device used in vitreoretinal surgery. Methods: Infrared absorption spectroscopy analysis of absolute water content (absolute humidity) was determined for a typical vitreoretinal air infusion line with and without the humidifying device. A variety of experimental laboratory conditions were utilized and designed to mimic those found in the operating room. The effect on physical parameters, such as flow rates and resistance to flow, were also determined. Results: While large bore infusion (LBI) lines had a negligible effect on flow rate and resistance to flow (reduction in infusion pressure), the standard 20G infusion line (SI) reduced flow rate and infusion pressure by approximately 25%. When used together, the humidifying device and SI reduced flow rate and infusion pressure by one third. The humidifying device was found to add 6.5 mg/L water content to the air infusion line system. Typical operating room (OR) air contains 9.5 mg/L water content, and 43.876 mg/L water content is required to saturate air at body temperature. Conclusion: To eliminate dehydration as a cause of intraocular morbidity, one must first saturate the infused air. If the visual field defects and other complications are eliminated, this would be good evidence for saturating infused air. As infusion pressure (flow rate) influences dehydration rate, unless saturated air is used, infusion pressure cannot be considered an independent variable in the analysis of field defects.
引用
收藏
页码:616 / 621
页数:6
相关论文
共 50 条
  • [41] Vitreoretinal complications of osteoodontokeratoprosthesis surgery
    Hughes, Edward H.
    Mokete, Bataung
    Ainsworth, Gerard
    Casswell, Anthony G.
    Eckstein, Michael B.
    Zambarakji, Hadi J.
    Gregor, Zdenek
    Rosen, Paul H.
    Herold, Jim
    Okera, Salim
    Liu, Christopher S. C.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (08): : 1138 - 1145
  • [42] The plasma blade in vitreoretinal surgery
    Singh, IR
    Singh, D
    Singh, R
    Kiranjit
    Singh, SK
    Singh, RSJ
    ANNALS OF OPHTHALMOLOGY, 2001, 33 (04) : 280 - 289
  • [43] Biocompatibility of dyes for vitreoretinal surgery
    Thaler, S.
    Schuettauf, F.
    Haritoglou, C.
    OPHTHALMOLOGE, 2009, 106 (01): : 11 - 15
  • [44] MIOSIS DURING VITREORETINAL SURGERY
    SMIDDY, WE
    GLASER, BM
    MICHELS, RG
    VITALE, S
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1990, 10 (01): : 42 - 46
  • [45] Aspirin is a hazard for vitreoretinal surgery
    Flaxel, CJ
    Blach, RK
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (05) : 486 - 486
  • [46] Vital Stains for Vitreoretinal Surgery
    Veckeneer, Marc
    Stalmans, Peter
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (04): : 673 - 677
  • [47] ANATOMIC SUCCESS AND VITREORETINAL SURGERY
    LICHTER, PR
    OPHTHALMOLOGY, 1988, 95 (07) : 857 - 858
  • [48] PERIBULBAR ANESTHESIA IN VITREORETINAL SURGERY
    BENEDETTI, S
    AGOSTINI, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1994, 14 (03): : 277 - 280
  • [49] Pneumatic tools for vitreoretinal surgery
    Romano, Mario R.
    Vallejo-Garcia, Jose Luis
    Randazzo, Alessandro
    Vinciguerra, Paolo
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 385 - 387
  • [50] Telcconsultation procedures in vitreoretinal surgery
    Azzolini, C
    Ciaccia, S
    Golinelli, A
    Mason, A
    Brancato, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U989 - U989