Humidity devices in vitreoretinal surgery

被引:7
|
作者
Franzco, BJTV
Newland, A
Polkinghorne, PJ
机构
[1] Auckland Hosp, Auckland Eye Dept, Dept Ophthalmol, Auckland, New Zealand
[2] Fisher & Paykel, Div Hlth Care, Auckland, New Zealand
关键词
dehydration injury; fluid-air exchange; humidity; visual field defect;
D O I
10.1097/00006982-200210000-00013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess a humidity device used in vitreoretinal surgery. Methods: Infrared absorption spectroscopy analysis of absolute water content (absolute humidity) was determined for a typical vitreoretinal air infusion line with and without the humidifying device. A variety of experimental laboratory conditions were utilized and designed to mimic those found in the operating room. The effect on physical parameters, such as flow rates and resistance to flow, were also determined. Results: While large bore infusion (LBI) lines had a negligible effect on flow rate and resistance to flow (reduction in infusion pressure), the standard 20G infusion line (SI) reduced flow rate and infusion pressure by approximately 25%. When used together, the humidifying device and SI reduced flow rate and infusion pressure by one third. The humidifying device was found to add 6.5 mg/L water content to the air infusion line system. Typical operating room (OR) air contains 9.5 mg/L water content, and 43.876 mg/L water content is required to saturate air at body temperature. Conclusion: To eliminate dehydration as a cause of intraocular morbidity, one must first saturate the infused air. If the visual field defects and other complications are eliminated, this would be good evidence for saturating infused air. As infusion pressure (flow rate) influences dehydration rate, unless saturated air is used, infusion pressure cannot be considered an independent variable in the analysis of field defects.
引用
收藏
页码:616 / 621
页数:6
相关论文
共 50 条
  • [31] Vitreoretinal surgery: Issues unresolved
    Chawla, Rohan
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (11) : 3434 - 3435
  • [32] Peribulbar anesthesia in vitreoretinal surgery
    Goldstein, A
    Mashhour, B
    Legras, JM
    Pouliquen, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 474 - 474
  • [33] PERFLUOROCARBON LIQUIDS IN VITREORETINAL SURGERY
    CHANG, S
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 1992, 32 (02) : 153 - 163
  • [34] Incidence of strabismus surgery after vitreoretinal surgery
    Johnson, William J.
    Bitner, Derek P.
    Bacig, Cole
    JOURNAL OF AAPOS, 2024, 28 (06):
  • [35] APRACLONIDINE HYDROCHLORIDE IN VITREORETINAL SURGERY
    PULIDO, JS
    MALLICK, KS
    SNEED, SR
    BLODI, CF
    ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (03) : 316 - 317
  • [36] Vitreoretinal surgery: Preemtive analgesia
    Kristin, N
    Schoenfeld, CL
    Bengisu, M
    Ludwig, K
    Scheider, A
    Kampik, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S78 - S78
  • [37] NEW ASPECTS IN VITREORETINAL SURGERY
    LAATIKAINEN, L
    ACTA OPHTHALMOLOGICA, 1988, 66 (02): : 233 - 233
  • [38] USEFUL ADJUNCTS FOR VITREORETINAL SURGERY
    GROSS, JG
    FREEMAN, WR
    GOLDBAUM, MH
    MENDEZ, TL
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (06) : 435 - 439
  • [39] The Evolution of Vitreoretinal Surgery Platforms
    Comaratta, Marc
    Hariprasad, Seenu M.
    Reddy, Rahul
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2017, 48 (07): : 532 - 538
  • [40] Advances in Surgery for Vitreoretinal Disease
    Huang, Suber S.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2021, 10 (01): : 1 - 2