Humidity devices in vitreoretinal surgery

被引:7
|
作者
Franzco, BJTV
Newland, A
Polkinghorne, PJ
机构
[1] Auckland Hosp, Auckland Eye Dept, Dept Ophthalmol, Auckland, New Zealand
[2] Fisher & Paykel, Div Hlth Care, Auckland, New Zealand
关键词
dehydration injury; fluid-air exchange; humidity; visual field defect;
D O I
10.1097/00006982-200210000-00013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess a humidity device used in vitreoretinal surgery. Methods: Infrared absorption spectroscopy analysis of absolute water content (absolute humidity) was determined for a typical vitreoretinal air infusion line with and without the humidifying device. A variety of experimental laboratory conditions were utilized and designed to mimic those found in the operating room. The effect on physical parameters, such as flow rates and resistance to flow, were also determined. Results: While large bore infusion (LBI) lines had a negligible effect on flow rate and resistance to flow (reduction in infusion pressure), the standard 20G infusion line (SI) reduced flow rate and infusion pressure by approximately 25%. When used together, the humidifying device and SI reduced flow rate and infusion pressure by one third. The humidifying device was found to add 6.5 mg/L water content to the air infusion line system. Typical operating room (OR) air contains 9.5 mg/L water content, and 43.876 mg/L water content is required to saturate air at body temperature. Conclusion: To eliminate dehydration as a cause of intraocular morbidity, one must first saturate the infused air. If the visual field defects and other complications are eliminated, this would be good evidence for saturating infused air. As infusion pressure (flow rate) influences dehydration rate, unless saturated air is used, infusion pressure cannot be considered an independent variable in the analysis of field defects.
引用
收藏
页码:616 / 621
页数:6
相关论文
共 50 条
  • [21] Local anesthetic in vitreoretinal surgery
    Chhabra, MS
    Prakash, G
    Vohra, R
    Garg, S
    OPHTHALMOLOGY, 2005, 112 (11) : 2052 - 2052
  • [22] Dyes in Vitreoretinal Surgery: An Update
    Stemplewitz, Birthe
    Wagenfeld, Lars
    Richard, Gisbert
    OPHTHALMOLOGICA, 2013, 230 : 16 - 17
  • [23] Vitreoretinal complications of cataract surgery
    Hakenova, J
    Rozsival, P
    SOE '97 - XI CONGRESS OF THE EUROPEAN SOCIETY OF OPHTHALMOLOGY, VOLS 1 AND 2, 1997, : 101 - 104
  • [24] In Situ Tremor in Vitreoretinal Surgery
    Li, Yifan
    Wolf, Mitchell D.
    Kulkarni, Amol D.
    Bell, James
    Chang, Jonathan S.
    Nimunkar, Amit
    Radwin, Robert G.
    HUMAN FACTORS, 2021, 63 (07) : 1169 - 1181
  • [25] Vitreoretinal surgery in difficult cases
    Pappas, Georgios
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [26] Temperature monitoring in vitreoretinal surgery
    Anatychuk, Lukyan
    Pasyechnikova, Nataliya
    Naumenko, Volodimir
    Kobylianskyi, Roman
    Nazaretyan, Rudolf
    Zadorozhnyy, Oleg
    ACTA OPHTHALMOLOGICA, 2021, 99
  • [27] Applications of endoscopy in vitreoretinal surgery
    Al Sabti, Khalid
    Raizada, Seemant
    Al Kandari, Jamal
    Wani, Vivek
    Gayed, Iskender
    Kumar, Niranjan
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (01): : 159 - 166
  • [28] Combined Cataract and Vitreoretinal Surgery
    Kook, D.
    Haritoglou, C.
    Kampik, A.
    Kohnen, T.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (08) : 630 - 637
  • [29] Combined cataract and vitreoretinal surgery
    Modis, Laszlo
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [30] VISUAL SUCCESS AND VITREORETINAL SURGERY
    WEINGEIST, TA
    OPHTHALMOLOGY, 1988, 95 (10) : 1305 - 1306