Information Theory Optimization of Acquisition Parameters for Improved Synthetic MRI Reconstruction

被引:0
作者
Mitchell, Drew [1 ]
Hwang, Ken-Pin [1 ]
Zhang, Tao [2 ]
Fuentes, David [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, 1881 East Rd, Houston, TX 77054 USA
[2] GE Healthcare, 1881 East Rd, Houston, TX 77054 USA
来源
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING | 2018年 / 10573卷
关键词
Synthetic MRI; multi-parameter mapping; information theory; mutual information; subsampling optimization; MAGNETIC-RESONANCE; T2; QUANTIFICATION; T1; BRAIN; IRON; TISSUE; T-2; TRUEFISP; DISEASE;
D O I
10.1117/12.2293860
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Synthetic magnetic resonance imaging (MRI) is a method for obtaining parametric maps of tissue properties from one scan and using these to reconstruct multiple contrast weighted images. This reduces the scan time necessary to produce multiple series of different contrast weightings and potentially provides additional diagnostic utility. For synthetic MRI, current acquisition parameter selection and subsampling approaches (such as variable density Poisson disc sampling) are heuristic in nature. We develop a mutual information-based mathematical framework to quantify the information content of a parameter space composed of k-space and several pulse sequence acquisition parameters of interest for model-based image reconstruction. We apply this framework to the signal model for a multi-contrast inversion-and T2-prepared gradient echo sequence. This pulse sequence is modeled for in silico data and used for the acquisition of phantom data. Mutual information between parametric map uncertainty and measured data is determined for variable acquisition parameters to characterize the performance of each acquisition. Mutual information is calculated by Gauss-Hermite quadrature and a global search over acquisition parameter space. We demonstrate the possibility of mutual information-guided subsampling schemes on phantom image data. Fully-sampled images of a silicone gel phantom and a water phantom are acquired on a 3T imager. Subsampling methods are applied to this data before it is reconstructed using the Berkeley Advanced Reconstruction Toolbox (BART). This framework allows for the strategic selection of synthetic MR acquisition parameters and subsampling schemes for specific applications and also provides a quantitative understanding of parameter space information content in an acquisition for multi-parameter mapping.
引用
收藏
页数:10
相关论文
共 25 条
  • [1] R2 relaxometry with MRI for the quantification of tissue iron overload in β-thalassemic patients
    Alexopoulou, E
    Stripeli, F
    Baras, P
    Seimenis, L
    Kattamis, A
    Ladis, V
    Efstathopoulos, E
    Brountzos, EN
    Kelekis, AD
    Kelekis, NL
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (02) : 163 - 170
  • [2] Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload
    Anderson, LJ
    Holden, S
    Davis, B
    Prescott, E
    Charrier, CC
    Bunce, NH
    Firmin, DN
    Wonke, B
    Porter, J
    Walker, JM
    Pennell, DJ
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 (23) : 2171 - 2179
  • [3] In vivo evaluation of brain iron in Alzheimer disease using magnetic resonance imaging
    Bartzokis, G
    Sultzer, D
    Cummings, J
    Holt, LE
    Hance, DB
    Henderson, VW
    Mintz, J
    [J]. ARCHIVES OF GENERAL PSYCHIATRY, 2000, 57 (01) : 47 - 53
  • [4] BRANTZAWADZKI M, 1984, AM J NEURORADIOL, V5, P125
  • [5] IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density
    Ehses, Philipp
    Seiberlich, Nicole
    Ma, Dan
    Breuer, Felix A.
    Jakob, Peter M.
    Griswold, Mark A.
    Gulani, Vikas
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 71 - 81
  • [6] MULTIPLE SPIN-ECHO MAGNETIC-RESONANCE IMAGING
    FEINBERG, DA
    MILLS, CM
    POSIN, JP
    ORTENDAHL, DA
    HYLTON, NM
    CROOKS, LE
    WATTS, JC
    KAUFMAN, L
    ARAKAWA, M
    HOENNINGER, JC
    BRANTZAWADZKI, M
    [J]. RADIOLOGY, 1985, 155 (02) : 437 - 442
  • [7] Use of tissue water as a concentration reference for proton spectroscopic imaging
    Gasparovic, Charles
    Song, Tao
    Devier, Deidre
    Bockholt, H. Jeremy
    Caprihan, Arvind
    Mullins, Paul G.
    Posse, Stefan
    Jung, Rex E.
    Morrison, Leslie A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1219 - 1226
  • [8] Helms G, 2000, NMR BIOMED, V13, P398, DOI 10.1002/1099-1492(200011)13:7<398::AID-NBM660>3.0.CO
  • [9] 2-W
  • [10] Quantification of T2 in the Abdomen at 3.0 T Using a T2-Prepared Balanced Turbo Field Echo Sequence
    Hoad, Caroline L.
    Cox, Eleanor F.
    Gowland, Penny A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) : 356 - 364