Comparison of GC-MS and HPLC for overcoming matrix interferences in the analysis of PAHs in smoked food

被引:36
|
作者
Chiu, CP [1 ]
Lin, YS [1 ]
Chen, BH [1 ]
机构
[1] FU JEN CATHOLIC UNIV,DEPT NUTR & FOOD SCI,TAIPEI 242,TAIWAN
关键词
gas chromatography; gas chromatography mass spectrometry; column liquid chromatography; polycyclic aromatic hydrocarbons; food analysis;
D O I
10.1007/BF02466743
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several separation and detection methods for polycyclic aromatic hydrocarbons (PAHs) in smoked chicken by GC and HPLC were compared. With HPLC and a gradient solvent system, all 16 PAHs could be simultaneously separated and detected by fluorescence with seven settings of programmable wavelength (excitation/emission). The presence of impurities in smoked chicken could interfere with the subsequent identification and quantification of PAHs by HPLC. With GC and a temperature programming method, all 16 PAHs could be separated and the PAHs in the chicken sample could be detected with an ion-trap mass spectrometer even in the presence of fat- or PAH-like impurities. Nine PAHs were identified by the former method while fourteen PAHs were identified by the latter method. The retention times by HPLC were shorter than those by GC, also, the former had better separation for most PAHs than the latter.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 50 条
  • [1] Comparison of GC-MS and HPLC for overcoming matrix interferences in the analysis of PAHs in smoked food
    C. P. Chiu
    Y. S. Lin
    B. H. Chen
    Chromatographia, 1997, 44 : 497 - 504
  • [2] Elimination of Matrix Interferences in GC-MS Analysis of Pesticides by Entropy Minimization
    Lu, Bo
    Lv, Yunbo
    Chua, Chun Kiang
    Zhang, Hua Jun
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2017, 64 (07) : 804 - 812
  • [3] Comparison of GC-MS and HPLC for the analysis ofAllium volatiles
    N. Mondy
    A. Naudin
    J. P. Christides
    N. Mandon
    J. Auger
    Chromatographia, 2001, 53 : S356 - S360
  • [4] Comparison of GC-MS and HPLC for the analysis of Allilum volatiles
    Mondy, N
    Naudin, A
    Christides, JP
    Mandon, N
    Auger, J
    CHROMATOGRAPHIA, 2001, 53 (Suppl 1) : S356 - S360
  • [5] Advances in GC-MS for Food Analysis
    Tranchida, Peter Quinto
    Dugo, Paola
    Mondello, Luigi
    LC GC EUROPE, 2012, : 25 - +
  • [6] Enhanced analysis of PAHs in tea using GC-MS/MS with hydrogen carrier gas
    Cutillas, Victor
    Oller-Serrano, Jose Luis
    Jesus, Florencia
    Ferrer, Carmen
    Fernandez-Alba, Amadeo R.
    MICROCHEMICAL JOURNAL, 2024, 207
  • [7] Determination of hydroxy derivatives of PAHs in sewage sludge by GC-MS/ MS
    Frydel, Laura
    Prus, Zuzanna
    Cwynar, Karolina
    Pamula, Justyna
    Pyssa, Justyna
    Rego, Rosa
    Styszko, Katarzyna
    DESALINATION AND WATER TREATMENT, 2025, 321
  • [8] COMPARISON OF SOME EXTRACTION TECHNIQUES FOR THE DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS (PAHs) FROM OILSEEDS BY GC-MS/MS
    Negoita, Mioara
    Mihai, Adriana Laura
    Adascalului, Alina Cristina
    SCIENTIFIC PAPERS-SERIES A-AGRONOMY, 2024, 67 (02): : 546 - 555
  • [9] The pollution profiles and human exposure risks of chlorinated and brominated PAHs in indoor dusts from e-waste dismantling workshops: Comparison of GC-MS, GC-MS/MS and GC x GC-MS/MS determination methods
    Tang, Jian
    Ma, Shengtao
    Liu, Ranran
    Yue, Congcong
    Li, Guiying
    Yu, Yingxin
    Yang, Yan
    An, Taicheng
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 394
  • [10] Analysis of Non-volatile Constituents in Dracocephalum Species by HPLC and GC-MS
    A. Kakasy
    Zs. Füzfai
    L. Kursinszki
    I. Molnár-Perl
    É. Lemberkovics
    Chromatographia, 2006, 63 : S17 - S22