Measurement of coronary blood flow velocity during handgrip exercise using breath-hold velocity encoded cine magnetic resonance imaging

被引:17
作者
Globits, S [1 ]
Sakuma, H [1 ]
Shimakawa, A [1 ]
Foo, TKF [1 ]
Higgins, CB [1 ]
机构
[1] GE CO,MED SYST,WAUKESHA,WI 53188
关键词
D O I
10.1016/S0002-9149(97)89291-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Since the first clinical application of the concept of coronary flow reserve, defined as the ratio of hyperemic flow to flow at rest, for the assessment of significance of coronary artery disease,(1-3) several studies have been performed using various invasive and noninvasive techniques to determine coronary flow reserve in humans.(4-7) With the introduction of rapid, segmented k-space breathholding techniques, visualization of the left and right coronary arteries has become possible.(8,9) Additionally, the introduction of time-of-flight and phase-contrast techniques allows noninvasive blood flow velocity measurements in the coronary arteries in vivo.(10-13) A recent study demonstrated the feasibility of fast velocity encoded cine magnetic resonance imaging (MRI) with k-space segmentation and view sharing reconstruction for displaying phasic coronary flow velocity curve in the cardiac cycle.(14) The purpose of the present study was to assess the applicability of breathhold velocity encoded cine (VEC)-MRI for measuring the increase in coronary blood flow velocity in response to interventions in normal subjects.
引用
收藏
页码:234 / &
页数:5
相关论文
共 18 条
[1]   CORONARY FLOW RESERVE [J].
BRADLEY, AJ ;
ALPERT, JS .
AMERICAN HEART JOURNAL, 1991, 122 (04) :1116-1128
[2]   PULSED DOPPLER CORONARY-ARTERY CATHETER - PRELIMINARY-REPORT OF A NEW TECHNIQUE FOR MEASURING RAPID CHANGES IN CORONARY-ARTERY FLOW VELOCITY IN MAN [J].
COLE, JS ;
HARTLEY, CJ .
CIRCULATION, 1977, 56 (01) :18-25
[3]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[4]   FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
GERVINO, E ;
LI, W .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :699-703
[5]   IMPROVED EJECTION FRACTION AND FLOW VELOCITY ESTIMATES WITH USE OF VIEW SHARING AND UNIFORM REPETITION TIME EXCITATION WITH FAST CARDIAC TECHNIQUES [J].
FOO, TKF ;
BERNSTEIN, MA ;
AISEN, AM ;
HERNANDEZ, RJ ;
COLLICK, BD ;
BERNSTEIN, T .
RADIOLOGY, 1995, 195 (02) :471-478
[6]   MEASUREMENT OF CORONARY SINUS BLOOD FLOW BY CONTINUOUS THERMODILUTION IN MAN [J].
GANZ, W ;
TAMURA, K ;
MARCUS, HS ;
DONOSO, R ;
YOSHIDA, S ;
SWAN, HJC .
CIRCULATION, 1971, 44 (02) :181-&
[7]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[8]  
HOFMAN MBM, 1994, BLOOD FLOW MEASUREME, P123
[9]   TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY EVALUATION OF CORONARY BLOOD-FLOW VELOCITY IN BASE-LINE CONDITIONS AND DURING DIPYRIDAMOLE-INDUCED CORONARY VASODILATION [J].
ILICETO, S ;
MARANGELLI, V ;
MEMMOLA, C ;
RIZZON, P .
CIRCULATION, 1991, 83 (01) :61-69
[10]   THE APPLICATION OF BREATH-HOLD PHASE-VELOCITY MAPPING TECHNIQUES TO THE MEASUREMENT OF CORONARY-ARTERY FLOOD FLOW VELOCITY - PHANTOM DATA AND INITIAL IN-VIVO RESULTS [J].
KEEGAN, J ;
FIRMIN, D ;
GATEHOUSE, P ;
LONGMORE, D .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :526-536