Simultaneous determination of imperatorin and its metabolite xanthotoxol in rat plasma by using HPLC-ESI-MS coupled with hollow fiber liquid phase microextraction

被引:16
作者
Zhang, Juan [1 ]
Zhang, Min [2 ]
Fu, Shan [1 ]
Li, Tao [1 ]
Wang, Shuang [1 ]
Zhao, Minmin [1 ]
Ding, Weijing [1 ]
Wang, Chunying [1 ]
Wang, Qiao [1 ]
机构
[1] Hebei Med Univ, Dept Pharmaceut Anal, Sch Pharm, Shijiazhuang 050017, Peoples R China
[2] Hebei Prov Chest Hosp, Qual Control Off, Shijiazhuang 050041, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 945卷
基金
中国国家自然科学基金;
关键词
Imperatorin; Xanthotoxol; Hollow fiber liquid phase microextraction; Pharmacokinetics; HPLC-ESI-MS; CHROMATOGRAPHY; BIOANALYSIS; EXTRACTION; SAMPLES; MATRIX; VALIDATION; OSTHOLE; URINE;
D O I
10.1016/j.jchromb.2013.11.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objective of the present study was to develop a new method for the simultaneous quantitation of imperatorin and its metabolite xanthotoxol in rat plasma. The samples were prepared with hollow fiber liquid phase microextraction (HF-LPME). The optimized extraction procedure was acquired by assessing extraction solvent, length of the fiber, agitation rate, extraction temperature and time. A comparison of sample pretreatment ways between HF-LPME and deproteinization with methanol was performed, which demonstrated less ion suppression and better sensitivity of HF-LPME. Analytes were separated on a C-18 column with a gradient elution consisted of methanol and water containing 1 mmol/L ammonium acetate. The detection was accomplished by electrospray ionization (ESI) source operating in the positive ionization mode. Selected-multiple-reaction monitoring (SMRM) scanning was employed, which guaranteed a higher sensitivity compared with MRM mode. Calibration curves were linear over investigated ranges with correlation coefficients greater than 0.9979. Precision varied from 0.26% to 14%, and the accuracy varied within +/- 5.5%. The developed method was successfully applied to the pharmacokinetic research of imperatorin and its metabolite xanthotoxol after oral administration of imperatorin to rats. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 36 条
[1]   Key elements of bioanalytical method validation for small molecules [J].
Bansal, Surendra ;
DeStefano, Anthony .
AAPS JOURNAL, 2007, 9 (01) :E109-E114
[2]   Determination of Buprenorphine, Fentanyl and LSD in Whole Blood by UPLCMS-MS [J].
Berg, Thomas ;
Jorgenrud, Benedicte ;
Strand, Dag Helge .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2013, 37 (03) :159-165
[3]   The mass transfer dynamics of hollow fiber liquid-phase microextraction and its application for rapid analysis of biological samples [J].
Cui, Shufen ;
Ouyang, Gangfeng ;
Duan, Guijiao ;
Hou, Jinxing ;
Luan, Tiangang ;
Zhang, Xu .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1266 :10-16
[4]   Automated polyvinylidene difluoride hollow fiber liquid-phase microextraction of flunitrazepam in plasma and urine samples for gas chromatography/tandem mass spectrometry [J].
Cui, Shufen ;
Tan, Shuo ;
Ouyang, Gangfeng ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (12) :2241-2247
[5]   Impact of organic solvent additive on the integrity of plasma samples in bioanalysis by LC-MS/MS [J].
Dicaire, Catherine ;
Mess, Jean-Nicholas ;
Furtado, Milton ;
Bergeron, Annik ;
Garofolo, Fabio .
BIOANALYSIS, 2013, 5 (19) :2359-2370
[6]  
[丁光超 DING Guangchao], 2008, [药物分析杂志, Chinese Journal of Pharmaceutical Analysis], V28, P1056
[7]   Simultaneous determination of chloropheniramine maleate and dextromethorphan hydrobromide in plasma sample by hollow fiber liquid phase microextraction and high performance liquid chromatography with the aid of chemometrics [J].
Ebrahimzadeh, Homeira ;
Shekari, Nafiseh ;
Saharkhiz, Zahra ;
Asgharinezhad, Ali Akbar .
TALANTA, 2012, 94 :77-83
[8]   Determination of ten monohydroxylated polycyclic aromatic hydrocarbons by liquid-liquid extraction and liquid chromatography/tandem mass spectrometry [J].
Fan, Ruifang ;
Ramage, Robert ;
Wang, Dongli ;
Zhou, Junqiang ;
She, Jianwen .
TALANTA, 2012, 93 :383-391
[9]   Comparison of conventional hollow fiber based liquid phase microextraction and electromembrane extraction efficiencies for the extraction of ephedrine from biological fluids [J].
Fotouhi, Lida ;
Yamini, Yadollah ;
Molaei, Saeideh ;
Seidi, Shahram .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (48) :8581-8586
[10]  
[宫雪菲 Gong XueFei], 2012, [药学服务与研究, Pharmaceutical Care and Research], V12, P374