Comparing the efficacy and safety of a novel monophasic waveform delivered by the passive implantable atrial defibrillator with biphasic waveforms in cardioversion of atrial fibrillation

被引:7
作者
Manoharan, G
Evans, N
Allen, D
Anderson, J
Adgey, J
机构
[1] Royal Victoria Hosp, Reg Med Cardiol Ctr, Belfast BT12 6BA, Antrim, North Ireland
[2] Univ Ulster, Dept Engn, Jordanstown, North Ireland
[3] Queens Univ Belfast, Belfast, Antrim, North Ireland
关键词
arrhythmia; fibrillation; cardioversion;
D O I
10.1161/01.CIR.0000124068.69162.4E
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - The passive implantable atrial defibrillator (PIAD) ( with no battery or discharging capacitor and powered transcutaneously by radio-frequency energy) delivering a novel monophasic low-tilt waveform is more efficacious than the standard monophasic waveform at atrial defibrillation. Standard biphasic (STB) waveforms, however, are more efficacious and safer than monophasic waveforms. This study compared the efficacy and safety of the PIAD waveform with biphasic waveforms. Methods and Results - Sustained atrial fibrillation (AF) was induced by rapid atrial pacing. Cardioversion was attempted via 2 atrial defibrillation leads. The efficacy of the PIAD was compared with 3 biphasic waveforms ( standard, single rounded, and double rounded) at varying voltage settings in 10 pigs. After a synchronized shock, hemodynamic changes between the PIAD, standard biphasic, and monophasic waveforms were compared at 1.5 and 3.0 J in 12 pigs. Myocardial injury ( biochemical and histological) after ten 5-J PIAD shocks was compared with a no-shock group in 14 pigs. The PIAD 100-V setting was significantly more efficacious than the STB (100/-50 V: 100% [1.88 +/- 0.02 J] versus 90% [0.89 +/- 0.0 J]; P = 0.025). No arrhythmic, hemodynamic, or myocardial injury was observed with the PIAD waveform. Conclusions - Defibrillation with the PIAD is more efficacious than with the STB waveform and appears safe. This device could provide a more effective option for cardioversion.
引用
收藏
页码:1686 / 1692
页数:7
相关论文
共 14 条
  • [1] TRANSVENOUS DEFIBRILLATION IN HUMANS VIA THE CORONARY SINUS
    BARDY, GH
    ALLEN, MD
    MEHRA, R
    JOHNSON, G
    FELDMAN, S
    GREENE, HL
    IVEY, TD
    [J]. CIRCULATION, 1990, 81 (04) : 1252 - 1259
  • [2] EFFECTS OF VARYING ELECTRODE CONFIGURATION WITH CATHETER-MEDIATED DEFIBRILLATOR PULSES AT THE CORONARY SINUS ORIFICE IN DOGS
    COLTORTI, F
    BARDY, GH
    REICHENBACH, D
    GREENE, HL
    THOMAS, R
    BREAZEALE, DG
    IVEY, TD
    [J]. CIRCULATION, 1986, 73 (06) : 1321 - 1333
  • [3] Cooper RAS, 1997, CIRCULATION, V95, P1487
  • [4] Feng YJ, 1998, AM J CLIN PATHOL, V110, P70
  • [5] GUYTON AC, 1996, TXB MED PHYSL, P149
  • [6] Rounded biphasic waveform reduces energy requirements for transvenous catheter cardioversion of atrial fibrillation and flutter
    Harbinson, MT
    Allen, JD
    Imam, Z
    Dempsey, G
    Anderson, JM
    Ayers, GM
    Adgey, AAJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01): : 226 - 229
  • [7] EFFECT OF DIRECT-CURRENT COUNTERSHOCKS ON REGIONAL MYOCARDIAL-CONTRACTILITY AND PERFUSION - EXPERIMENTAL STUDIES
    KERBER, RE
    MARTINS, JB
    GASCHO, JA
    MARCUS, ML
    GRAYZEL, J
    [J]. CIRCULATION, 1981, 63 (02) : 323 - 332
  • [8] Waveform optimization for internal atrial defibrillation: Effects of waveform rounding, phase duration, and voltage swing
    Kidwai, BJ
    Allen, JD
    Harbinson, MT
    Mcintyre, A
    Anderson, J
    Adgey, AAJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (08): : 1198 - 1207
  • [9] Resuscitation after prolonged ventricular fibrillation with use of monophasic and biphasic waveform pulses for external defibrillation
    Leng, CT
    Paradis, NA
    Calkins, H
    Berger, RD
    Lardo, AC
    Rent, KC
    Halperin, HR
    [J]. CIRCULATION, 2000, 101 (25) : 2968 - 2974
  • [10] Novel passive implantable atrial defibrillator using transcutaneous radiofrequency energy transmission successfully cardioverts atrial fibrillation
    Manoharan, G
    Evans, N
    Kidwai, B
    Allen, D
    Anderson, J
    Adgey, J
    [J]. CIRCULATION, 2003, 108 (11) : 1382 - 1388