The evaluation of a new digital semi-automated system for the radiological assessment of distal radial fractures

被引:13
作者
Grainger, AJ [1 ]
Duryea, J
Elliott, JM
Genant, HK
机构
[1] Gen Infirm, Dept Radiol, Leeds LS1 3EX, W Yorkshire, England
[2] Univ Calif San Francisco, Dept Skeletal Radiol, Osteoporosis & Arthritis Res Grp, San Francisco, CA 94143 USA
[3] Musgrave Pk Hosp, Dept Radiol, Belfast, Antrim, North Ireland
关键词
wrist fracture; measurement; computer analysis;
D O I
10.1007/s00256-002-0526-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To compare intra- and inter-observer variation for measurements of wrist deformity using a manual method of measurement and a semi-automated digital system developed in our department. Design: Four observers measured radial angle, radial shift, radial length, palmar tilt, and dorsal shift on ten wrist-fracture films using a standardised protocol. Each observer made measurements directly from the radiograph on three occasions, and on a further three occasions digitised images were viewed and measurements made with semi-automated on-screen measurement tools. Results: Manual measurements took 12 min per case compared with 3 min for the digital system. The digital system resulted in improved intra-observer variation for all measurements and an improvement in inter-observer variation for all measurements except posterior tilt. Conclusion: The new system allows greater precision in assessing fracture reduction and follow-up. Its principal application is in studies that utilise the wrist as a model for fracture healing.
引用
收藏
页码:457 / 463
页数:7
相关论文
共 12 条
[1]   QUANTIFICATION OF ERROR IN MEASUREMENT OF RADIAL INCLINATION ANGLE AND RADIAL-CARPAL DISTANCE [J].
DIBENEDETTO, MR ;
LUBBERS, LM ;
RUFF, ME ;
NAPPI, JF ;
COLEMAN, CR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (03) :399-400
[2]  
Frykman G, 1967, ACTA ORTHOP SCAND S, V108, P3
[3]   POSTEROANTERIOR WRIST RADIOGRAPHY - IMPORTANCE OF ARM POSITIONING [J].
HARDY, DC ;
TOTTY, WG ;
REINUS, WR ;
GILULA, LA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (04) :504-508
[4]   EXTERNAL FIXATION OR PLASTER FOR SEVERELY DISPLACED COMMINUTED COLLES FRACTURES - A PROSPECTIVE-STUDY OF ANATOMICAL AND FUNCTIONAL RESULTS [J].
HOWARD, PW ;
STEWART, HD ;
HIND, RE ;
BURKE, FD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (01) :68-73
[5]   EXTERNAL FIXATION FOR INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
JAKIM, I ;
PIETERSE, HS ;
SWEET, MBE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :302-306
[6]   X-ray film measurements for healed distal radius fractures [J].
Kreder, HJ ;
Hanel, DP ;
McKee, M ;
Jupiter, J ;
McGillivary, G ;
Swiontkowski, MF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (01) :31-39
[7]  
Kreder HJ, 1996, J HAND SURG-AM, V21A, P532
[8]   COLLES FRACTURE - DOES THE ANATOMICAL RESULT AFFECT THE FINAL FUNCTION [J].
MCQUEEN, M ;
CASPERS, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :649-651
[9]  
METZ VM, 1993, ORTHOP CLIN N AM, V24, P217
[10]  
PORTER M, 1987, CLIN ORTHOP RELAT R, P241