Varus/valgus alignment of the femur in total knee arthroplasty. Can accuracy be improved by pre-operative CT scanning?

被引:28
作者
Kinzel, V
Scaddan, M
Bradley, B
Shakespeare, D
机构
[1] Warwick Hosp, Dept Orthopaed Surg, Warwick, England
[2] Warwick Hosp, Dept Radiol, Warwick, England
关键词
total knee arthroplasty; varus; valgus;
D O I
10.1016/S0968-0160(03)00106-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In a series of 80 consecutive knee replacements, pre-operative scout scans of the femur were taken and the angle between the slope of the worn femur and the mechanical axis was measured. At surgery the angle of the distal femoral cut was adjusted to make it perpendicular to the mechanical axis. Post-operative scans revealed that 97.5% of femoral components were implanted within 2degrees of the target. The angle between a perfectly positioned virtual intra-medullary rod on the pre-operative films and the mechanical axis showed marked variations between individuals indicating that the use of a fixed angular correction from an intramedullary rod is unreliable even under perfect circumstances. In practice it is subject to further inaccuracy due to variability in the anatomy of the femur and rod placement. With the advent of robotically assisted surgery, the technical limits of conventional instruments need to be explored in terms of improving accuracy for each individual patient. In terms of the coronal alignment of the femur, this involves some degree of preplanning rather than relying on arbitrary targets based on incorrect assumptions. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 18 条
  • [1] CATES HE, 1993, CLIN ORTHOP RELAT R, P32
  • [2] Engh G A, 1990, J Arthroplasty, V5, P1, DOI 10.1016/S0883-5403(06)80002-1
  • [3] Faris P M, 1988, J Arthroplasty, V3, P355, DOI 10.1016/S0883-5403(88)80037-8
  • [4] The importance of femoral intramedullary entry point in knee arthroplasty
    Harding, IJ
    Crawford, RW
    Mclardy-Smith, P
    Murray, DW
    [J]. KNEE, 1999, 6 (03) : 207 - 210
  • [5] ALIGNMENT OF TOTAL KNEE ARTHROPLASTY - THE RELATIONSHIP TO RADIOLUCENCY AROUND THE TIBIAL COMPONENT
    HARVEY, IA
    MANNING, MP
    SAMPATH, SAC
    JOHNSON, R
    ELLOY, MA
    [J]. MEDICAL ENGINEERING & PHYSICS, 1995, 17 (03) : 182 - 187
  • [6] Accuracy of intramedullary femoral alignment in total knee replacement: intraoperative assessment of alignment rod position
    Jeffery, JA
    [J]. KNEE, 1999, 6 (03) : 211 - 215
  • [7] Varus/valgus alignment of the femoral component in total knee arthroplasty
    Lam, LO
    Shakespeare, D
    [J]. KNEE, 2003, 10 (03) : 237 - 241
  • [8] Lonner JH, 1996, CLIN ORTHOP RELAT R, P102
  • [9] MORELAND JR, 1988, CLIN ORTHOP RELAT R, P49
  • [10] MORELAND JR, 1991, INTRAMEDULLARY EXTRA