Automated Detection Framework of the Calcified Plaque with Acoustic Shadowing in IVUS Images

被引:42
作者
Gao, Zhifan [1 ,2 ,3 ]
Guo, Wei [4 ]
Liu, Xin [2 ,3 ]
Huang, Wenhua [5 ]
Zhang, Heye [2 ,3 ]
Tan, Ning [4 ]
Hau, William Kongto [6 ]
Zhang, Yuan-Ting [2 ,3 ,7 ]
Liu, Huafeng [8 ]
机构
[1] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
[2] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen, Peoples R China
[3] Chinese Acad Sci, Key Lab Biomed Informat & Hlth Engn, Shenzhen, Peoples R China
[4] Guangdong Acad Med Sci, Guangdong Gen Hosp, Guangdong Cardiovasc Inst, Dept Cardiol, Guangzhou, Guangdong, Peoples R China
[5] Southern Med Univ, Inst Clin Anat, Guangzhou, Guangdong, Peoples R China
[6] Univ Hong Kong, LiKaShing Fac Med, Inst Cardiovasc Med & Res, Hong Kong, Hong Kong, Peoples R China
[7] Chinese Univ Hong Kong, Dept Elect Engn, Joint Res Ctr Biomed Engn, Hong Kong, Hong Kong, Peoples R China
[8] Zhejiang Univ, Dept Opt Engn, State Key Lab Modern Opt Instrumentat, Hangzhou 310027, Zhejiang, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 11期
基金
中国国家自然科学基金;
关键词
CORONARY-ARTERY CALCIUM; EXPERT CONSENSUS DOCUMENT; INTRAVASCULAR ULTRASOUND; COMPUTED-TOMOGRAPHY; AMERICAN-COLLEGE; PROGNOSTIC VALUE; SEGMENTATION; RISK;
D O I
10.1371/journal.pone.0109997
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intravascular Ultrasound (IVUS) is one ultrasonic imaging technology to acquire vascular cross-sectional images for the visualization of the inner vessel structure. This technique has been widely used for the diagnosis and treatment of coronary artery diseases. The detection of the calcified plaque with acoustic shadowing in IVUS images plays a vital role in the quantitative analysis of atheromatous plaques. The conventional method of the calcium detection is manual drawing by the doctors. However, it is very time-consuming, and with high inter-observer and intra-observer variability between different doctors. Therefore, the computer-aided detection of the calcified plaque is highly desired. In this paper, an automated method is proposed to detect the calcified plaque with acoustic shadowing in IVUS images by the Rayleigh mixture model, the Markov random field, the graph searching method and the prior knowledge about the calcified plaque. The performance of our method was evaluated over 996 in-vivo IVUS images acquired from eight patients, and the detected calcified plaques are compared with manually detected calcified plaques by one cardiology doctor. The experimental results are quantitatively analyzed separately by three evaluation methods, the test of the sensitivity and specificity, the linear regression and the Bland-Altman analysis. The first method is used to evaluate the ability to distinguish between IVUS images with and without the calcified plaque, and the latter two methods can respectively measure the correlation and the agreement between our results and manual drawing results for locating the calcified plaque in the IVUS image. High sensitivity (94.68%) and specificity (95.82%), good correlation and agreement (>96.82% results fall within the 95% confidence interval in the Student t-test) demonstrate the effectiveness of the proposed method in the detection of the calcified plaque with acoustic shadowing in IVUS images.
引用
收藏
页数:18
相关论文
共 46 条
  • [11] Detection and quantification of calcifications in intravascular ultrasound images by automatic thresholding
    Filho, E. Santos
    Saijo, Y.
    Tanaka, A.
    Yoshizawa, M.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (01) : 160 - 165
  • [12] Forbes C., 2011, STAT DISTRIBUTIONS
  • [13] Friedman A., 2011, PARTIAL DIFFERENTIAL
  • [14] Atherothrombosis and high-risk plaque Part I: Evolving concepts
    Fuster, V
    Moreno, PR
    Fayad, ZA
    Corti, R
    Badimon, JJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) : 937 - 954
  • [15] Gao Z., 2014, P INT C HLTH INFORMA, P197
  • [16] Gil D, 2002, C AN SOC ESP ING BIO, P133
  • [17] Goodman J. W., 2007, Speckle phenomena in optics: theory and applications
  • [18] SOME FUNDAMENTAL PROPERTIES OF SPECKLE
    GOODMAN, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (11) : 1145 - 1150
  • [19] ACCF/AHA 2007 Clinical Expert Consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain
    Greenland, Philip
    Bonow, Robert O.
    Brundage, Bruce H.
    Budoff, Matthew J.
    Eisenberg, Mark J.
    Grundy, Scott M.
    Lauer, Michael S.
    Post, Wendy S.
    Raggi, Paolo
    Redberg, Rita F.
    Rodgers, George P.
    Shaw, Leslee J.
    Taylor, Allen J.
    Weintraub, William S.
    Harrington, Robert A.
    Abrams, Jonathan
    Anderson, Jeffrey L.
    Bates, Eric R.
    Eisenberg, Mark J.
    Grines, Cindy L.
    Hlatky, Mark A.
    Lichtenberg, Robert C.
    Lindner, Jonathan R.
    Pohost, Gerald M.
    Schofield, Richard S.
    Shubrooks, Samuel J., Jr.
    Stein, James H.
    Tracy, Cynthia M.
    Vogel, Robert A.
    Wesley, Deborah J.
    Lewin, John C.
    Arend, Thomas E., Jr.
    Bradfield, Lisa
    Velasquez, Maria
    Barrett, Erin A.
    Christiansen, Peg
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (03) : 378 - 402
  • [20] HERRINGTON DM, 1992, COMPUT CARDIOL, P103