Development of self-powered neutron detectors for neutron flux monitoring in HCLL and HCPB ITER-TBM

被引:20
|
作者
Angelone, M. [1 ]
Klix, A. [2 ]
Pillon, M. [1 ]
Batistoni, P. [1 ]
Fischer, U. [2 ]
Santagata, A. [3 ]
机构
[1] Assoc ENEA EURATOM Fus ENEA CR Frascati, I-00044 Frascati, Italy
[2] Karlsruhe Inst Technol, Assoc KIT EURATOM, D-76344 Eggenstein Leopoldshafen, Germany
[3] ENEA CR Casaccia, I-00100 Rome, Italy
关键词
Neutron activation; Thermal neutron spectrum; Fast neutron spectrum; Beta decay; FISPACT code; Emitter;
D O I
10.1016/j.fusengdes.2014.01.077
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Self powered neutron detectors (SPND) have a number of interesting properties (e.g. small dimensions, capability to operate in harsh environments, absence of external bias), so they are attractive neutron monitors for TBM in ITER. However, commercially available SPNDs are optimized for operation in a thermal nuclear reactor where the neutron spectrum is much softer than that expected in a TBM. This fact can limit the use of SPND in a TBM since the effective cross sections for the production of beta emitters are much lower in a fast neutron spectrum. This work represents the first attempt to study SPNDs as neutron flux monitors for TBM. Three state-of-the-art SPND available on the market were bought and tested using fast neutrons at TAPIRO fast neutron source of ENEA Casaccia and with 14 MeV neutrons at the Frascati neutron generator (FNG). The results clearly indicate that in fast neutron spectra, the response of SPNDs is much lower than in thermal neutron flux. Activation calculations were performed using the FISPACT code to find out possible material candidates for SPND suitable for operation in TBM neutron spectra. (C) 2014 EURATOM. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:2194 / 2198
页数:5
相关论文
共 50 条
  • [1] SELF-POWERED NEUTRON DETECTORS FOR REACTOR FLUX MONITORING
    HILBORN, JW
    NUCLEONICS, 1964, 22 (02): : 69 - &
  • [2] SELF-POWERED NEUTRON DETECTORS
    ACCINNI, F
    TONOLINI, F
    ENERGIA NUCLEARE, 1968, 15 (05): : 311 - &
  • [3] SELF-POWERED NEUTRON DETECTORS
    JOSLIN, CW
    NUCLEAR ENGINEERING INTERNATIONAL, 1972, 17 (192): : 399 - &
  • [4] POSSIBILITY OF NEUTRON-SPECTRA FLUX MEASUREMENT BY SELF-POWERED NEUTRON DETECTORS
    KIRSANOV, VS
    BABULEVI.EN
    ROZENBLY.ND
    SHIPOVSK.YM
    ZAGADKIN, VA
    MITELMAN, MG
    ATOMNAYA ENERGIYA, 1972, 32 (01): : 65 - +
  • [5] CALIBRATION OF SELF-POWERED NEUTRON DETECTORS
    SULCOSKI, MF
    WARREN, HD
    NUCLEAR SCIENCE AND ENGINEERING, 1983, 85 (03) : 245 - 250
  • [6] High Flux Isotope Reactor Irradiation of Self-Powered Neutron Detectors
    Mulligan, Padhraic L.
    Sweeney, Daniel C.
    Godsey, Kara M.
    Ezell, N. Dianne
    Petrie, Christian M.
    Proceedings of 13th Nuclear Plant Instrumentation, Control and Human-Machine Interface Technologies, NPIC and HMIT 2023, 2023, : 1420 - 1430
  • [7] Computational study of a chromium self-powered detector for neutron flux monitoring in the test blanket module of ITER
    Raj, Prasoon
    Angelone, Maurizio
    Fischer, Ulrich
    Klix, Axel
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 908 : 10 - 17
  • [8] NEUTRON SENSITIVITY OF PLATINUM SELF-POWERED DETECTORS
    LYNCH, GF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (04) : 1094 - 1094
  • [9] DEVELOPMENT AND IN-CORE APPLICATION OF SELF-POWERED NEUTRON DETECTORS.
    Gebureck, P.
    Hofmann, W.
    Jaschik, W.
    Seifritz, W.
    Stegemann, D.
    1973, : 783 - 802
  • [10] A study on the sensitivity of self-powered neutron detectors (SPNDs)
    Lee, W
    Cho, G
    Kim, K
    Kim, HJ
    Choi, Y
    Park, MG
    Kim, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1587 - 1591