Monthly use of a real-time continuous glucose monitoring system as an educational and motivational tool for poorly controlled type 1 diabetes adolescents

被引:9
|
作者
Glowinska-Olszewska, B. [1 ]
Tobiaszewska, M. [1 ]
Luczynski, W. [1 ]
Bossowski, A. [1 ]
机构
[1] Med Univ Bialystok, Dept Paediat, Div Cardiol, PL-15274 Bialystok, Poland
来源
ADVANCES IN MEDICAL SCIENCES | 2013年 / 58卷 / 02期
关键词
diabetes type 1; adolescents; real-time continuous glucose monitoring; metabolic control; education; IMPROVED GLYCEMIC CONTROL; SENSOR-AUGMENTED PUMP; PEDIATRIC-PATIENTS; PROLONGED USE; CHILDREN; THERAPY; HYPOGLYCEMIA; VARIABILITY; LIFE;
D O I
10.2478/ams-2013-0024
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Purpose: Experience with the use of real-time continuous glucose monitoring systems (RT-CGMS) in teenagers with type 1 diabetes mellitus (T1DM) is limited. We aimed to assess the possibility of glycaemic control improvement and to characterize the group of adolescents, who may gain long-term benefits from the use of the RT-CGMS. Methods: Forty T1DM patients, aged 14.6 +/- 2.1 years, with diabetes duration 7.4 +/- 3.6 years and initial HbA(1)c 9.3 +/- 1.5% were recruited. The analysis was based on one-month glucose sensors use, combined with the thorough family support. Patients were analysed in groups according to baseline HbA(1)c: below and above 7.5%, and 10.0%. Comparison between patients with or without improvement in HbA(1)c after 3-month follow-up was also performed. Patients' satisfaction based on the questionnaire was assessed. Results: HbA(1)c level in entire study group decreased after three months, from 9.3 +/- 1.0% to 8.8 +/- 1.6% (P<0.001). In the group with HbA(1)c improvement, reduction was the highest: 9.0 +/- 1.3% vs. 8.0 +/- 1.2% (P<0.001). Only the group with initial HbA(1)c>10% did not achieve significant improvement: 11.2 +/- 0.5% vs. 10.9 +/- 1.1 (P=0.06). In satisfaction questionnaire the lowest scores (negative opinion) were reported by group of patients with initial HbA(1)c above 10%, while the highest scores (positive opinion) were found in the group with improvement of HbA(1)c after 3 month follow-up. Conclusion: Short-term use of CGMS RT, united with satisfaction questionnaire, performed in poorly controlled teenagers with T1DM, can be useful in defining the group of young patients, who can benefit from long-term CGMS RT use in metabolic control improvement.
引用
收藏
页码:344 / 352
页数:9
相关论文
共 50 条
  • [11] Real-Time Continuous Glucose Monitoring in Adolescents and Young Adults With Type 2 Diabetes Can Improve Quality of Life
    Chesser, Hannah
    Srinivasan, Shylaja
    Puckett, Cassidy
    Gitelman, Stephen E.
    Wong, Jenise C.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (04): : 911 - 919
  • [12] Use of telemedicine in subjects with type 1 diabetes equipped with an insulin pump and real-time continuous glucose monitoring
    Gonzalez-Molero, Inmaculada
    Dominguez-Lopez, Marta
    Guerrero, Mercedes
    Carreira, Monica
    Caballero, Felix
    Rubio-Martin, Eleazara
    Linares, Francisca
    Cardona, Isabel
    Teresa Anarte, Maria
    Soledad Ruiz de Adana, Maria
    Soriguer, Federico
    JOURNAL OF TELEMEDICINE AND TELECARE, 2012, 18 (06) : 328 - 332
  • [13] Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials
    Dicembrini, I.
    Cosentino, C.
    Monami, M.
    Mannucci, E.
    Pala, L.
    ACTA DIABETOLOGICA, 2021, 58 (04) : 401 - 410
  • [14] Measures of Glycemic Variability in Type 1 Diabetes and the Effect of Real-Time Continuous Glucose Monitoring
    El-Laboudi, Ahmed H.
    Godsland, Ian F.
    Johnston, Desmond G.
    Oliver, Nick S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (12) : 806 - 812
  • [15] Use of Continuous Glucose Monitoring Systems in Children with Type 1 Diabetes
    Minnock, Pantea P.
    Howe, Carol J.
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2011, 23 (02) : 273 - +
  • [16] Improved Glycemic Control in Insulin-Treated Individuals With Poorly Controlled Type 2 Diabetes Through Combined Structured Education With Real-Time Continuous Glucose Monitoring
    Yoo, Jee Hee
    Jun, Ji Eun
    Kwak, Soo Heon
    Kim, Jae Hyeon
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025,
  • [17] Use of Short-Term Real-Time Continuous Glucose Monitoring in Type 1 Diabetes Patients on Continuous Intraperitoneal Insulin Infusion: A Feasibility Study
    Logtenberg, Susan J. J.
    Kleefstra, Nanne
    Groenier, Klaas H.
    Gans, Rijk O. B.
    Bilo, Henk J. G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (05) : 293 - 299
  • [18] Safety of using real-time sensor glucose values for treatment decisions in adolescents with poorly controlled type 1 diabetes mellitus: a pilot study
    Fox, Larry A.
    Balkman, Emilie
    Englert, Kim
    Hossain, Jobayer
    Mauras, Nelly
    PEDIATRIC DIABETES, 2017, 18 (04) : 271 - 276
  • [19] Remote Application and Use of Real-Time Continuous Glucose Monitoring by Adults with Type 2 Diabetes in a Virtual Diabetes Clinic
    Bergenstal, Richard M.
    Layne, Jennifer E.
    Zisser, Howard
    Gabbay, Robert A.
    Barleen, Nathan A.
    Lee, Amy Armento
    Majithia, Amit R.
    Parkin, Christopher G.
    Dixon, Ronald F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (02) : 128 - 132
  • [20] Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes
    Vinals, Clara
    Quiros, Carmen
    Gimenez, Marga
    Conget, Ignacio
    DIABETES THERAPY, 2019, 10 (03) : 929 - 936