High dynamic range, temperature compensated fibre Bragg gratings sensor for structural monitoring of buildings

被引:0
作者
Smeu, E. [1 ]
Gnewuch, H. [2 ]
Jackson, D. A. [2 ]
Podoleanu, A. [2 ]
机构
[1] Univ Politehn Bucuresti, Dept Phys, Laser Metrol Lab, Spl Independentei 313, Bucharest 060042, Romania
[2] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NR, Kent, England
来源
SEVENTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS | 2006年 / 6345卷
关键词
structural monitoring; FBG; temperature compensation; strain; sensitivity; resolution; linearity; dynamic tests;
D O I
10.1117/12.693086
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The distance changes between structural elements inside a building (e.g. walls, pillars, stairs, etc.) ought to be monitored, especially in seismic-prone areas, in order to assess its stability. Fibre Bragg grating (FBG) sensors are now the most interesting choice for this purpose, since several gratings can be included in the fibre, resulting in a quasi-distributed sensor, which can be illuminated using a single light source and interrogated simply by a single optical spectrum analyzer (OSA), using wavelength multiplexing. The paper deals with such a sensor, which was installed for monitoring the distance changes in a construction joint between two building blocks inside the University "Politehnica" of Bucharest. Since this city is placed in a seismic-prone area, we use a fast scanning OSA, so that the dynamic behavior of the monitored construction joint is expected to be captured during future earthquakes. Slow drifts of the construction joint width will be also monitored. The paper describes the sensor structure and working principle, the experimental tests and main parameters evaluation. The reported sensor is temperature compensated. It has an estimated distance resolution better or equal to 10 gm, and a linearity of +0.2%...-0.35% for displacements up to 0.55 mm. Simulated dynamic tests are also reported.
引用
收藏
页数:8
相关论文
共 10 条
[1]  
DEWYNTERMARTY V, 1997, P 12 INT C OPT FIB S, P600
[2]   Improvements on the multiplexing system using a 2D spectrograph for FBG based sensor arrays [J].
Hu, Y ;
Bridge, B ;
Zhang, L ;
Bennion, I ;
Chen, S .
EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 1998, 3483 :288-291
[3]   HIGH-RESOLUTION FIBER-GRATING BASED STRAIN SENSOR WITH INTERFEROMETRIC WAVELENGTH-SHIFT DETECTION [J].
KERSEY, AD ;
BERKOFF, TA ;
MOREY, WW .
ELECTRONICS LETTERS, 1992, 28 (03) :236-238
[4]   High resolution strain sensing by locking lasers to fiber-Bragg gratings [J].
Lissak, B ;
Arie, A ;
Tur, M .
EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 1998, 3483 :250-254
[5]   Dynamic strain measurement with a fibre Bragg grating sensor system [J].
Liu, JG ;
Schmidt-Hattengerger, C ;
Borm, G .
MEASUREMENT, 2002, 32 (02) :151-161
[6]   Extended range interrogation scheme for fibre Bragg grating sensors using a multimode laser diode [J].
Moreira, PJ ;
Ferreira, LA ;
Santos, JL ;
Farahi, F .
EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 1998, 3483 :278-282
[7]  
RASTOGI PK, 1997, OPTICAL MEASUREMENT, P233
[8]  
SHIBA K, 2003, P 16 INT C OPT FIB S, P492
[9]  
UDD E, 2003, P OFS 16 NAR JAP, P496
[10]  
VOHRA ST, 1999, P 13 INT C OPT FIB S