Strength model for heat-damaged reinforced concrete circular columns confined with carbon fibre reinforced polymer fabrics

被引:14
作者
Al-Kamaki, Yaman S. S. [1 ,2 ]
Al-Mahaidi, Riadh [1 ]
Bennetts, Ian [1 ]
机构
[1] Swinburne Univ Technol, Fac Sci Engn & Technol, Hawthorn, Vic 3122, Australia
[2] Univ Duhok, Duhok, Kurdistan Regio, Iraq
关键词
Design-oriented strength model; carbon fibre reinforced polymer; reinforced concrete column strength; heating; photogrammetry; STRESS-STRAIN MODEL; COMPRESSIVE BEHAVIOR; FRP; COMPOSITE; TEMPERATURES; FIRE;
D O I
10.1177/0731684415601901
中图分类号
TB33 [复合材料];
学科分类号
摘要
The strength models for fibre reinforced polymer wrapped columns available in the research literature were developed at ambient temperatures. To date, no experimental or analytical data have been available on the behaviour of large-scale reinforced concrete circular columns loaded during heating and cooling and subsequently wrapped with carbon fibre reinforced polymer fabrics. This paper deals with the development of new design-oriented strength models to predict the compressive strength of unheated and heat-damaged reinforced concrete columns confined with carbon fibre reinforced polymer. In this paper, 18 O 204 mm x 750 mm identical reinforced concrete columns were fabricated and tested, of which 12 were subjected to elevated temperatures under stress and then subsequently confined with carbon fibre reinforced polymer sheets after air cooling. The variables considered in these tests included the level of heat exposure and the number of carbon fibre reinforced polymer sheet layers. The digital image correlation technique and conventional foil gauges were used to determine the axial strain of carbon fibre reinforced polymer coupons and axial and lateral strains over the surface of unheated and heat-damaged carbon fibre reinforced polymer-wrapped columns. It was found that it is possible to repair heat-damaged concrete even to the extent of achieving the original compressive strength prior to heating through the use of appropriate carbon fibre reinforced polymer materials. The developed models were compared with the strength of columns obtained from test results of both unheated and heat-damaged carbon fibre reinforced polymer-wrapped columns and also with the existing ambient temperature strength models.
引用
收藏
页码:1833 / 1855
页数:23
相关论文
共 69 条
[1]   Effectiveness of advanced composites in repairing heat-damaged RC columns [J].
Al-Nimry, Hanan ;
Haddad, Rami ;
Afram, Saad ;
Abdel-Halim, Mohammed .
MATERIALS AND STRUCTURES, 2013, 46 (11) :1843-1860
[2]   Compressive Strength of FRP-Confined Concrete at Elevated Temperatures [J].
Al-Salloum, Y. A. .
POLYMERS & POLYMER COMPOSITES, 2008, 16 (09) :611-620
[3]  
Al-Zubaidy H, 2013, THESIS MONASH U MELB
[4]  
[Anonymous], 2012, 834 ISO
[5]  
[Anonymous], 2009, 5275 BS EN ISO
[6]  
[Anonymous], DES MAN 4 STRENGTH R
[7]  
[Anonymous], 4402R ACI
[8]  
[Anonymous], 1992, DELIVERY VERSUS PAYM, P1
[9]  
[Anonymous], 2002, CANCSAS806
[10]  
[Anonymous], 2001, B FIB, V14